Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

INDEX uniform system

Here c(x, t)dx is the concentration of material with index in the slice (x, x + dx) whose rate constant is k(x) K(x, z) describes the interaction of the species. The authors obtain some striking results for uniform systems, as they call those for which K is independent of x (Astarita and Ocone, 1988 Astarita, 1989). Their second-order reaction would imply that each slice reacted with every other, K being a stoichiometric coefficient function. Only if K = S(z -x) would we have a continuum of independent parallel second-order reactions. In spite of the physical objections, the mathematical challenge of setting this up properly remains. Ho and Aris (1987) have shown how not to do it. Astarita and Ocone have shown how to do something a little different and probably more sensible physically. We shall see that it can be done quite generally by having a double-indexed mixture with parallel first-order reactions. The first-order kinetics ensures the individuality of the reactions and the distribution... [Pg.190]

It appears very likely that this stronger result is also valid in the non-selfadjoint case, as with the open uniform systems of Section 1.9. One implication of the stronger result is that steady states with index +1 that have 2m (m >0) eigenvalues A (0,1), are unstable. [Pg.93]

A uniform system of retention classification according to a solute s relative location between a pair of homologous reference compounds on a specific column under specific conditions. It compares the time a compound is eluting from the column to the times of a set of standard compounds. The most common set of compounds used for retention indices are hydrocarbons typically from C5 to C30, separated in the order of boiling points, Kovats index. [Pg.828]

It should be stated that the nomenclature of the triazine derivatives is not uniform, e.g., in Chemical Abstracts the compounds are often indexed according to another sy.stem than that used in the original papers, and an additional system could have been used for this review. To avoid further complications, the author will u.se the commonest nomeclature in accordance with the representative monographs in this field (see references 12 and 45.)... [Pg.191]

The factor f reduces the oscillation amplitude symmetrically about R - R0, facilitating straightforward calculation of polymer refractive index from quantities measured directly from the waveform (3,). When r12 is not small, as in the plasma etching of thin polymer films, the first order power series approximation is inadequate. For example, for a plasma/poly(methyl-methacrylate)/silicon system, r12 = -0.196 and r23 = -0.442. The waveform for a uniformly etching film is no longer purely sinusoidal in time but contains other harmonic components. In addition, amplitude reduction through the f factor does not preserve the vertical median R0 making the film refractive index calculation non-trivial. [Pg.237]

Such requirements are expected to assure that the dosage form is formulated and manufactured appropriately to ensure that the index or marker ingredients are uniformly distributed and will dissolve in the gastrointestinal tract and be available for absorption. No assumption is made that the marker or index compound selected for demonstration of dissolution is responsible for the purported effect. The test is valuable in that it assures that the formulation technology used is reflective of the state-of-the-art technology, provides a means to evaluate lot-to-lot performance over a product s shelf-life and that excipients used to facilitate transfer of the index or marker ingredients of the botanical to the human system are appropriate. [Pg.415]

The second system investigated 101) (polystyrene macromonomer and perfluoro-alkyl acrylate) is also of great interest. The polymerization is carried out in trifluoro-benzene with AIBN as the initiator to a conversion of the order of 60 %. The graft copolymer formed is soluble in a number of solvents in which the poly(perfluoro-alkyl acrylate) backbone would be insoluble, e.g. in THF and diethyl ether. The easy formation of foams indicates the low surface energy which is characteristic of fluorinated polymers. Double-detection GPC (UV and refractive index) showed that the distribution of polystyrene branches within the sample was quite uniform. [Pg.45]

These photopolymer systems were found to contain both volume refractive-index modulation and thickness modulation the latter constitutes a thin hologram. The volume hologram was shown to be present by removing one glass cover and covering the surface with the same monomer mixture. Upon uniform overall exposure, the... [Pg.252]

The compression of uniform samples to the point where the force exceeds the structural capacity causes it to permanently deform and essentially break (4). A typical load-deformation curve can be used to derive values for yield stress, yield strain, and compressive yield work, and depending on the linearity of the onset of compression, a compressive modulus may be obtained (4). These measurements can be used to provide an index of hardness for fats, which have been successfully correlated to the textural attributes of hardness and spreadability obtained through sensory evaluation (4). Unfortunately, these tests are destructive in nature and yield minimal information about the native microstructure of the system. [Pg.197]

Plating electrolytes are often characterized by their throwing power , an empirical parameter which reflects the ability of the electrolyte system to deposit precipitates with an overall uniform layer thickness. It has become commonplace in electrochemical practice to express throwing power in terms of the so-called Wagner index fVa... [Pg.202]

The pH accordingly acquires primary importance as an index of the state of the many interactive acid-base systems of which seawater is composed. Two factors are essential to the most fruitful application of this acid-base parameter. The first is that pH measurements possess reproducibility of a high order, and the second is that the numbers obtained have a clear meaning in terms of the processes of interest. To achieve the necessary reproducibility, uniform procedures and standards for the measurement must be accepted by all workers in the field. [Pg.110]


See other pages where INDEX uniform system is mentioned: [Pg.114]    [Pg.56]    [Pg.438]    [Pg.260]    [Pg.38]    [Pg.98]    [Pg.436]    [Pg.27]    [Pg.168]    [Pg.293]    [Pg.71]    [Pg.438]    [Pg.87]    [Pg.593]    [Pg.6]    [Pg.256]    [Pg.389]    [Pg.374]    [Pg.50]    [Pg.1]    [Pg.59]    [Pg.13]    [Pg.14]    [Pg.15]    [Pg.701]    [Pg.247]    [Pg.257]    [Pg.258]    [Pg.264]    [Pg.243]    [Pg.173]    [Pg.89]    [Pg.260]    [Pg.36]    [Pg.147]    [Pg.457]    [Pg.27]    [Pg.1671]   
See also in sourсe #XX -- [ Pg.83 , Pg.88 ]




SEARCH



INDEX uniform

© 2024 chempedia.info