Sevecek P, Filipi B, Zapletalova I. Modification of the oxygen index test for better evaluation of the relative flammability. Fire Mater. 1981 5 39-40. [Pg.416]

Wide-width tensile tests provide a better measure of tme tensile strength than small-width tensile tests. The test data are presented in a load per unit width versus strain curve from which the modulus values (Eq. [7.1]) can be calculated. The specimens tested are not confined, as it would be in its end use this test does not result in a tme design value, especially for GTX-N. Nevertheless it is the index test for GTXs (Fig. 7.5). [Pg.125]

Objects other than balls or cones are used as index tests for GTXs. The pyramid drop test is similar to the cone drop test but with a different shape. The pyramid should represent the angularity of a stone but the test is not used in this industry. [Pg.142]

The tendency for a solvent to form deposits by polymerization of impurities such as olefins is measured by the test for potential gums . Olefin content can also be represented by the bromine index , which is a measure of the degree of unsaturation (see paragraph 3.4.1). [Pg.274]

Phenol quahty tests and analyses can be divided into two categories wet lab and Hquid and gas chromatography. In the wet lab, phenol is tested for pH, sohdification point, solubiUty in water, bromine index, color, and distillation ranges. Phenol concentration, impurities, and CHP contents are analy2ed using highly automated Hquid and gas chromatography. [Pg.290]

ISO 4660, Bubber, Bjaw Natural—Color Index Test, International Organization for Standardization, Geneva, Switzerland, 1991. [Pg.276]

Over the years many attempts have been made to provide some measure of the maximum service temperature which a material will be able to withstand without thermal degradation rendering it unfit for service. Quite clearly any figure will depend on the time the material is likely to be exposed to elevated temperatures. One assessment that is being increasingly quoted is the UL 746B Relative Temperature Index Test of the Underwriters Laboratories (previously known as the Continuous Use Temperature Rating or Index). [Pg.186]

The molecular uniformity of constituting components of a nb/lcb glucan fraction of potato starch was investigated with Sepharose CL 2B (Fig. 16.16) as well as with Sephacryl S-1000 (Fig. 16.17). Therefore, each of the subsequently eluted 3-ml fractions was analyzed on their potential to form inclusion complexes with iodine, a sensitive test for the presence of nb/lcb glucans. Results are shown in Fig. 16.17 in terms of branching index, the ratio of extinction of pure iodine solution and of nb/lcb glucan/iodine complex the higher the index, the more pronounced the nb/lcb characteristics. [Pg.480]

Since the corrosion resistance of anodic films on aluminium is markedly dependent on the efficacy of sealing (provided the film thickness is adequate for the service conditions), tests for sealing quality are frequently employed as an index of potential resistance to corrosion. While it is admitted that an unequivocal evaluation of corrosion behaviour can only be obtained by protracted field tests in service, accelerated corrosion tests under closely controlled conditions can also provide useful information in a shorter time within the limitations of the particular test environment employed. [Pg.698]

When testing for a tannin reserve or tannin index, the presence of natural color aids detection. Testing for tannin is simple and relatively accurate using either a permanganate reduction test (development of permanent purple color) or lignin/tannic acid polymer test (tungstate blue color). [Pg.409]

The HcReynolds abroach, which was based on earlier theoretical considerations proposed by Rohrschneider, is formulated on the assumption that intermolecular forces are additive and their Individual contributions to retention can be evaluated from differences between the retention index values for a series of test solutes measured on the liquid phase to be characterized and squalane at a fixed temperature of 120 C. The test solutes. Table 2.12, were selected to express dominant Intermolecular interactions. HcReynolds suggested that ten solutes were needed for this purpose. This included the original five test solutes proposed by Rohrschneider or higher molecular weight homologs of those test solutes to improve the accuracy of the retention index measurements. The number of test solutes required to adequately characterize the solvent properties of a stationary phase has remained controversial but in conventional practice the first five solutes in Table 2.12, identified by symbols x through s have been the most widely used [6). It was further assumed that for each type of intermolecular interaction, the interaction energy is proportional to a value a, b, c, d, or e, etc., characteristic of each test solute and proportional to its susceptibility for a particular interaction, and to a value x, X, Z, U, s, etc., characteristic of the capacity of the liquid phase... [Pg.99]

Creatine kinase, creatine kinase myocardial band Creatine kinase (CK) enzymes are found in many isoforms, with varying concentrations depending on the type of tissue. Creatine kinase is a general term used to describe the nonspecific total release of all types of CK, including that found in skeletal muscle (MM), brain (BB) and heart (MB). CK MB is released into the blood from necrotic myocytes in response to infarction and is a useful laboratory test for diagnosing myocardial infarction. If the total CK is elevated, then the relative index (RI), or fraction of the total that is composed of CK MB, is calculated as follows RI = (CK MB/CK total) x 100. An RI greater than 2 is typically diagnostic of infarction. [Pg.1563]

In other halogen-containing systems, such as flexible PVC and polyolefins, it is preferable to use the zinc borate in conjunction with antimony oxide for maximum performance. In flexible PVC, for example, the zinc borate alone is not very effective in the Oxygen Index test (Fig. 6), but a combination of the zinc borate and antimony oxide (1 1 ratio) outperforms equal weight of antimony oxide at a total loading of more than 10 phr (4). In the presence of alumina trihydrate (ATH), the beneficial effect of using a combination of the zinc borate and antimony oxide is dramatically increased (Fig. 7). [Pg.158]

Fig. 103 shows all scenario profits in the one-phase and the two-phase optimization case as well as the sales quantity index the two-phase optimization results do not disperse as strong as the one-phase-optimization. Besides, the worst case scenario is comparably better than the worst case scenario of the one-phase-optimization strategy. The plan is more cautious supply quantities are reduced leading to lower expected profits but better minimum profits in the worst case scenario. Although robustness is not measured it get s visible in the numerical tests for the 2-phase optimization approach. [Pg.249]


See other pages where INDEX tests for is mentioned: [Pg.483]    [Pg.560]    [Pg.317]    [Pg.284]    [Pg.634]    [Pg.483]    [Pg.560]    [Pg.317]    [Pg.284]    [Pg.634]    [Pg.314]    [Pg.222]    [Pg.366]    [Pg.154]    [Pg.111]    [Pg.432]    [Pg.549]    [Pg.105]    [Pg.105]    [Pg.164]    [Pg.449]    [Pg.1033]    [Pg.538]    [Pg.103]    [Pg.100]    [Pg.189]    [Pg.306]    [Pg.364]    [Pg.225]    [Pg.785]    [Pg.322]    [Pg.315]    [Pg.91]    [Pg.467]    [Pg.148]    [Pg.161]    [Pg.137]    [Pg.156]    [Pg.45]   