For analysis in solutions, the most frequently used CL reaction is alkaline oxidation of luminol and lucigenin in the presence of hydrogen peroxide as oxidant, although sodium hypochlorite, sodium perborate, or potassium ferricyanide may also be used. CL reactions involving alkaline oxidation have been used to indicate acid-base, precipitation, redox, or complexometric titration endpoints either by the appearance or the quenching of CL when an excess of titrant is present [114, 134], An example of these mechanisms is shown in Figure 14. [Pg.24]

For instance, quantification of ultratrace levels of sulfide is feasible with inexpensive flow analyzers relying on the catalytic action of the target analyte on the hydrogen peroxide-luminol chemiluminescent (CL) reaction. Furthermore, in combination with online gas diffusion processes, it is possible to suppress matrix effects, e.g. metals, ions, oxidants, and organic compounds, and improve selectivity as a result. The MSFIA-CL method depicted in Figure 7.9 features a linear working range... [Pg.184]

Detecting the presence of small, even invisible, amounts of blood is routine. Physical characteristics of dried stains give minimal information, however, as dried blood can take on many hues. Many of the chemical tests for the presence of blood rely on the catalytic peroxidase activity of heme (56,57). Minute quantities of blood catalyze oxidation reactions between colorless materials, eg, phenolphthalein, luco malachite green, luminol, etc, to colored or luminescent ones. The oxidant is typically hydrogen peroxide or sodium perborate (see Automated instrumentation,hematology). [Pg.487]

Another way to produce light from luminol is electrogenerated chemiluminescence6, 1. Luminol is oxidized using a positively biased electrode and in the presence of hydrogen peroxide the light emission occurs. [Pg.158]

The photosensitized results are from I.B.C. Matheson and J. Lee 118h It is seen that the quantum yields in photosensitized oxidation depend on the concentrations of luminol and base, and on temperature. At higher temperature (50°) and low luminol concentrations, the quantum yields reached those of hemin-catalyzed hydrogen peroxide oxidation of luminol in aqueous-alkaline solution. Primary products of the photosensitized oxidation are singlet oxygen (1Ag02) or a photoperoxide derived from methylene blue, but neither of these is directly responsible for the luminol chemiluminescence. [Pg.104]

The chemiluminescence of luminol in aqueous alkaline hydrogen-peroxide oxidation is catalyzed by many metal ions (see K. Weber and coworkers 184), A. K. Babko and coworkers 185 b p. 159). This catalytic... [Pg.130]

Luminol amidine 132, synthesized from luminol and the Vilsmeier reagent from DMF and thionyl chloride, has been proposed as a suitable luminol derivative for analytical purposes because, unlike luminol, it can be easily purified by recrystallization from water. 132 exhibits a chemiluminescence quantum yield of about 20% of luminol in ferricyanide-catalyzed oxidation by aqueous alkaline hydrogen peroxide Amax of the emission is 452 nm 196>. [Pg.131]

The flow-cell design was introduced by Stieg and Nieman [166] in 1978 for analytical uses of CL. Burguera and Townshend [167] used the CL emission produced by the oxidation of alkylamines by benzoyl peroxide to determine aliphatic secondary and tertiary amines in chloroform or acetone. They tested various coiled flow cells for monitoring the CL emission produced by the cobalt-catalyzed oxidation of luminol by hydrogen peroxide and the fluorescein-sensitized oxidation of sulfide by sodium hypochlorite [168], Rule and Seitz [169] reported one of the first applications of flow injection analysis (FTA) in the CL detection of peroxide with luminol in the presence of a copper ion catalyst. They... [Pg.28]

In the early studies on luminol and related hydrazides the systems used were composed of either sodium or potassium hydroxide, as base, hydrogen peroxide as the oxidizing agent (more recently molecular oxygen, hypochlorite, iodide, and permanganate have also been used), and some type of initiator or activator. This initiator was frequently hypochlorite, persulfate, a transition metal... [Pg.108]

The luminol reaction has been used for the determination of oxidizing agents such as hydrogen peroxide, for enzymes such as peroxidase and xanthine oxidase, and for metal ions such as copper or cobalt that catalyze this CL reaction [24],... [Pg.110]

The lack of selectivity can be circumvented by coupling a postcolumn flow system to a liquid chromatograph. This has promoted the development of a number of efficient liquid chromatography-CL approaches [16, 17]. Eluted analytes are mixed with streams of the substrate and oxidant (in the presence or absence of a catalyst or inhibitor) and the mixed stream is driven to a planar coiled flow cell [18] or sandwich membrane cell [19] in an assembly similar to those of flow injection-CL systems. Many of these postcolumn flow systems are based on an energy-transfer CL process [20], In others, the analytes are mixtures of metal ions and the luminol-hydrogen peroxide system is used to generate the luminescence [21],... [Pg.181]

Other cationic surfactants such as TTAB, DTAB, DODAB, STAC, CEDAB, and DDDAB have been used in CL reactions with less frequency. Thus, tetradecyltrimethylammonium bromide [TTAB] has been used to increase the sensitivity of the method to determine Fe(II) and total Fe based on the catalytic action of Fe(II) in the oxidation of luminol with hydrogen peroxide in an alkaline medium [47], While other surfactants such as HTAB, hexadecylpiridinium bromide (HPB), Brij-35, and SDS do not enhance the CL intensity, TTAB shows a maximum enhancement at a concentration of 2.7 X 10 2 M (Fig. 11). At the same time it was found that the catalytic effect of Fe(II) is extremely efficient in the presence of citric acid. With regard to the mechanism of the reaction, it is thought that Fe(II) forms an anionic complex with citric acid, being later concentrated on the surface of the TTAB cationic micelle. The complex reacts with the hydrogen peroxide to form hydroxy radical or superoxide ion on the... [Pg.302]

The CL system luminol-hydrogen peroxide was characterized by Hoshino and Hinze in HTAC reversed micelles, formed in a 6 5 (v/v) chloroform-cyclohexane mixture [63], The results indicate that such a CL system can be used from an analytical point of view in a pH interval of 7.8-9.0 without the need to add a catalyst or a co-oxidant. In these conditions an analytical method was established for determination of hydrogen peroxide that, apart from supplying much milder conditions compared to the usual situation in an aqueous medium, is also acceptably precise and reproducible. [Pg.306]

Luminol derivatives produce emission of light by oxidation with oxygen and hydrogen peroxide under alkaline conditions. By utilizing this reaction, peroxides such as hydrogen peroxide and lipid hydroperoxides can be determined after HPLC separation. Metal ions [e.g., iron(II), cobalt(II), etc.] catalyzing the luminol CL reaction can also be determined. [Pg.396]

Based on the reaction of luminol and hydrogen peroxide, detection by electrogenerated CL (ECL) was also applied in CE [85], In this detection technique, which has been used until now in LC and in FIA, the production of light is followed by an oxidation or reduction reaction at an electrode that serves the... [Pg.451]

In this system, choline formed by acetylcholinesterase is oxidized by choline oxidase and the hydrogen peroxide produced is determined using the luminol/peroxidase CL reaction. The sensor has been used for the analysis of Paraoxon and Aldicarb pesticides, with detection limits of 0.75 pg/L and 4 pg/ L, respectively. Recoveries in the range of 81-108% in contaminated samples of soils and vegetables were obtained. [Pg.578]

Here A and B are non-luminescence molecules. The C is the excited state of the product C. Often these reactions involve oxidation reactions and the presence of a catalyst. Both chemical and biochemical reactions could generate the photon. The intensity of the photons are collected through optical fibers and measured with a photon detector. The most successful chemiluminescence sensor for the detection of the hydrogen peroxide [13] is based on luminol using ferricyanide as catalyst... [Pg.759]

A well known example of a CL reaction is the oxidation of luminol (63) with strong oxidants like permanganate, hypochlorite, and especially hydrogen peroxide in alkaline medium (Fig. 24). A representative example of sensitized CL is the oxidation of oxalates with hydrogen peroxide in the presence of a fluorophore [158],... [Pg.72]


See other pages where Hydrogen peroxide luminol oxidation is mentioned: [Pg.106]    [Pg.164]    [Pg.181]    [Pg.414]    [Pg.2058]    [Pg.92]    [Pg.120]    [Pg.158]    [Pg.965]    [Pg.103]    [Pg.105]    [Pg.105]    [Pg.111]    [Pg.184]    [Pg.25]    [Pg.31]    [Pg.70]    [Pg.178]    [Pg.184]    [Pg.198]    [Pg.448]    [Pg.452]    [Pg.465]    [Pg.479]    [Pg.536]    [Pg.552]    [Pg.574]    [Pg.736]    [Pg.970]    [Pg.48]    [Pg.152]    [Pg.209]   
See also in sourсe #XX -- [ Pg.1244 , Pg.1245 , Pg.1246 ]




SEARCH



Luminol

Luminol, oxidation

Luminol-peroxide

Oxidants peroxides

Oxidation hydrogen peroxide

Oxidation peroxidation

Oxides peroxides

Oxidizers hydrogen peroxide

Peroxidative oxidation

Peroxidative oxidation hydrogen peroxide)

Peroxides oxidation

© 2024 chempedia.info