Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Hydraulic loading

Evaluates the performance of each unit of a wastewater treatment plant based on hydraulic loadings, solid flux loadings, food/microorganism ratios, sludge age, settleability, and related parameters. [Pg.283]

A valve with bridges and internal compartments for form and dry under vacuum and cake discharge under pressure with 2-2.5 bar snap or 0.2-0.25 bar constant blow. Most disc filters are fitted with one valve only however two valves are often mounted on both drive and nondrive ends with long barreled filters or when the hydraulic loadings are high. [Pg.212]

A variation for one vendor is shown in Figure 26. The design and control of the system takes into consideration the following parameters flow rate, water temperature, waste characteristics, chemical pretreatment options, solids loading, hydraulic loading, the air to solids ratio. Units are designed on the basis of peak flow rate expected. [Pg.320]

Hydraulic loading Hydraulic loading refers to the flows (MGD or m3/day) to a treatment plant or treatment process. [Pg.616]

Maintain rleaiance at minimum to prevent extrusion under hydraulic load 0,75 mm i... [Pg.510]

Higher than expected hardness levels are usually attributed to inadequate chemical addition or poor sludge recirculation. High turbidity is often attributable to fluctuating hydraulic loading on the process plant. [Pg.313]

The plate structure must be designed to support the hydraulic loads on the plate during operation, and the loads imposed during construction and maintenance. Typical design values used for these loads are ... [Pg.564]

Hydraulic load 600 N/m2 live load on the plate, plus 3000 N/m2 over the downcomer seal area. [Pg.564]

System component Filter beds, media, backwash mechanism, pumps, and controls. The filter beds were sized for hydraulic loading of 81 L/min/m2 (2gpm/ft2). [Pg.378]

Method The process used for oily waste stream after emulsion breaking-gravity oil separation. System component Filter modules sized on the basis of hydraulic loading of 1 L/min/m2. [Pg.378]

Method A packed-bed throwaway system to remove organic pollutants from oily waste stream. System component A contactor system, and a pump station designed for a contact time of 30 min and hydraulic loading of 162 L/min/m2 (4gpm/ft2). [Pg.378]

Gravity flow in downflow carbon beds is usually controlled at hydraulic loadings less than 9.78 m3/h/m2 (4 gal/min/ft2). Upflow carbon beds with bed expansion should be considered when headloss is expected. It should be noted that TSS will break through an upflow carbon bed at about 10% bed expansion. [Pg.727]

The 4-ft-circular Supracell DAF was used for this testing. The flotation area is 10 ft2. Maximum hydraulic loading is 30 U.S. gpm. The unit was set up adjacent to the aeration basin at the waste treatment plant. A small sump pump was used to pump mixed liquor to the Supracell DAF. [Pg.1180]

Type of Filter BOD5 Loading (kg/m3 d) Hydraulic Loading (m3/m2 d) Depth (m) BOD Removal (%) Medium... [Pg.1245]


See other pages where Hydraulic loading is mentioned: [Pg.325]    [Pg.325]    [Pg.325]    [Pg.269]    [Pg.293]    [Pg.942]    [Pg.2213]    [Pg.2218]    [Pg.2224]    [Pg.505]    [Pg.403]    [Pg.403]    [Pg.281]    [Pg.282]    [Pg.282]    [Pg.598]    [Pg.952]    [Pg.289]    [Pg.290]    [Pg.378]    [Pg.1156]    [Pg.1156]    [Pg.1156]    [Pg.1157]    [Pg.1159]    [Pg.1159]    [Pg.1174]    [Pg.1174]    [Pg.1175]    [Pg.1175]    [Pg.1177]    [Pg.1177]    [Pg.1185]    [Pg.1186]    [Pg.39]    [Pg.279]    [Pg.421]   