High tandem mass spectrometry

Nikolai LN, McClure EL, MacLeod SL, Wong CS (2006) Stereoisomer quantification of the Beta-blocker drugs atenolol, metoprolol, and propranolol in wastewaters by chiral high-performance liquid chromatography-tandem mass spectrometry. J Chromatogr A 1131 103-109... [Pg.223]

Bijlsma L, Sancho JV, Pitarch E, Ibanez M, Hernandez F (2009) Simultaneous ultra-high-pressure liquid chromatography-tandem mass spectrometry determination of amphetamine and amphetamine-like stimulants, cocaine and its metabolites, and a cannabis metabolite in surface water and urban wastewater. J Chromatogr A 1216(15) 3078-3089... [Pg.224]

Castiglioni S, Bagnati R, Calamari D, Fanelli R, Zuccato E (2005) A multiresidue analytical method using solid-phase extraction and high-pressure liquid chromatography tandem mass spectrometry to measure pharmaceuticals of different therapeutic classes in urban waste-waters. J Chromatogr A 1092 206-215... [Pg.227]

Q-ToF-LC-MS-MS quadrupole time-of-flight mass analyser in combination with (high performance) liquid chromatography and tandem mass spectrometry... [Pg.16]

Wu, X. and Prior, R.L., Identification and characterization of anthocyanins hy high performance liquid chromatography-electrospray ionization-tandem mass spectrometry in common foods in the United States vegetables, nuts, and grains, J. Agric. Food Chem., 53, 3101, 2005. [Pg.84]

Tian, Q. et al., Screening for anthocyanins using high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry with precursor-ion analysis, product-ion analysis, common-neutral-loss analysis, and selected reaction monitoring, J. Chromatogr. A, 1091, 72, 2005. [Pg.501]

A further extension of the DFG S19 method was achieved when polar analytes and those unsuitable for GC were determined by LC/MS or more preferably by liquid chromatography/tandem mass spectrometry (LC/MS/MS). Triple-quadrupole MS/MS and ion trap MS" have become more affordable and acceptable in the recent past. These techniques provide multiple analyte methods by employing modes such as time segments, scan events or multiple injections. By improving the selectivity and sensitivity of detection after HPLC separation, the DFG S19 extraction and cleanup scheme can be applied to polar or high molecular weight analytes, and cleanup steps such as Si02 fractionation or even GPC become unnecessary. [Pg.57]

The most widely regarded approach to accomplish the determination of as many pesticides as possible in as few steps as possible is to use MS detection. MS is considered a universally selective detection method because MS detects all compounds independently of elemental composition and further separates the signal into mass spectral scans to provide a high degree of selectivity. Unlike GC with selective detectors, or even atomic emission detection (AED), GC/MS may provide acceptable confirmation of the identity of analytes without the need for further information. This reduces the need to re-inject a sample into a separate GC system (usually GC/MS) for pesticide confirmation. Through the use of selected ion monitoring (SIM), efficient ion-trap or quadrupole devices, and/or tandem mass spectrometry (MS/MS), modern GC/MS instruments provide LODs similar to or lower than those of selective detectors, depending on the analytes, methods, and detectors. [Pg.762]

MS detection does not necessarily require as highly resolved GC separations as in the case of selective detectors because the likelihood of an overlapping mass spectral peak among pesticides with the same retention time is less than the likelihood of an overlapping peak from the same element. Unfortunately, this advantage cannot always be optimized because SIM and current gas chromatography/tandem mass spectrometry (GC/MS/MS) methods, it is difficult to devise sequential SIM or MS/MS retention time windows to achieve fast GC separations for approximately > 50 analytes in a single method. [Pg.762]

Full acceptance of HPLC/MS methods by the US EPA OPP as enforcement methods occurred between 1998 and 2001. For example, in 1998, the EPA OPP accepted HPLC/MS (without MS/MS) methods as primary enforcement methods, and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) only was suitable for confirmatory methods. However, in 2001, HPLC/MS/MS methods also became acceptable for primary enforcement. Table 4 summarizes the types of methods that were validated by the EPA OPP method validation program, for both food tolerance enforcement methods and environmental chemistry methods. [Pg.766]

Homish, R. E. and Wiest, J. R., Quantitation of spectinomycin residues in bovine tissues by ion-exchange high-performance liquid chromatography with post-column derivatization and confirmation by reversed-phase high performance chromatography-atmospheric pressure chemical ionization tandem mass spectrometry, /. Chromatogr. A, 812, 123, 1998. [Pg.312]

SEC-ESI-FTMS combines the size separation based technique of SEC with one of the most powerful mass spectrometric techniques of FTMS offering high mass accuracy (ppm), ultrahigh resolving power (>10(i) 6) and the capability to perform tandem mass spectrometry. The technique enables generation of oligomer elution profiles, which can be used for accurate calibration of standard SEC data. Coupling of SEC to ESI-MS is further described in ref. [710],... [Pg.529]

If we consider only a few of the general requirements for the ideal polymer/additive analysis techniques (e.g. no matrix interferences, quantitative), then it is obvious that the choice is much restricted. Elements of the ideal method might include LD and MS, with reference to CRMs. Laser desorption and REMPI-MS are moving closest to direct selective sampling tandem mass spectrometry is supreme in identification. Direct-probe MS may yield accurate masses and concentrations of the components contained in the polymeric material. Selective sample preparation, efficient separation, selective detection, mass spectrometry and chemometric deconvolution techniques are complementary rather than competitive techniques. For elemental analysis, LA-ICP-ToFMS scores high. [Pg.744]

A different strategy has been applied in our work, that emphasizes the importance of DNA stability on hole transfer within double-stranded DNA. This work is based on determination of the overall yield of oxidized nucleosides that arise from the conversion of initially generated purine and pyrimidine radical cations within DNA exposed to two-photon UVC laser pulses. On the one hand, this work benefits from the excellent current knowledge of chemical reactions involving the radical cations of DNA bases, and on the other hand, from major analytical improvements that include recent availability of the powerful technique of high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (CLHP-ESI-MS/MS) [16-18]. [Pg.13]


See other pages where High tandem mass spectrometry is mentioned: [Pg.542]    [Pg.1029]    [Pg.15]    [Pg.62]    [Pg.104]    [Pg.223]    [Pg.4]    [Pg.27]    [Pg.53]    [Pg.55]    [Pg.426]    [Pg.734]    [Pg.736]    [Pg.758]    [Pg.769]    [Pg.1146]    [Pg.379]    [Pg.401]    [Pg.402]    [Pg.405]    [Pg.406]    [Pg.408]    [Pg.411]    [Pg.412]    [Pg.514]    [Pg.735]    [Pg.13]    [Pg.17]    [Pg.16]    [Pg.27]    [Pg.25]    [Pg.242]    [Pg.253]   