Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

High performance liquid chromatography gels

Typically, quantitative protein determination is done on the one hand by colorimetric or nephelometric methods, on the other hand for more difficult analytical problems by more sophisticated techniques such as high performance liquid chromatography (HPLC), gel-electrophoresis and immunoassay. However, these methods are tedious, time-consuming and expensive. [Pg.100]

Purification of poloxamers has been extensively investigated due to their use in medical applications, the intention often being to remove potentially toxic components. Supercritical fluid fractionation and liquid fractionation have been used successfully to remove low-molecular weight impurities and antioxidants from poloxamers. Gel filtration, high-performance liquid chromatography (HPLC), and ultrafiltration through membranes are among the other techniques examined [5]. [Pg.768]

GC = gas chromatography ECD = electron capture detector EIA = enzyme-immunoassay GPC = gel permeation chromatography HPLC = high-performance liquid chromatography ITMS = ion trap mass spectrometer LSE = liquid solid extraction MS = mass spectrometry RSD = relative standard deviation SPE = solid phase extraction... [Pg.259]

Analyses were performed by gel permeation chromatography (GPC) and by high performance liquid chromatography (HPLC). Gel filtration of oligosaccharides was effected in a thermostated (65 <>C) column (210 X 1.5 i.d.) filled with polycrylamide gel (Bio-gel P2, 200-400 mesh Bio Rad-USA), using stilled water as eluent (flow rate 30 ml.h-1). [Pg.551]

To determine the nature of the associated state, gel filtration high-performance liquid chromatography (HPLC) has been performed in a number of detergents with... [Pg.144]

Reversed-phase high-performance liquid chromatography (HPLC) column 50 mm x 3.2-mm i.d. with Kromasil 5- um Gig packing High-performance liquid chromatograph coupled to a triple-quadrupole mass spectrometer with an atmospheric pressure chemical ionization (APCI) source Gel permeation chromatograph with a 60 mm x 25-mm i.d. column packed with Bio-Beads SX-3 (50-g)... [Pg.1169]

Pyrimidifen is extracted from plant materials with methanol-water (7 3, v/v). The extracts are concentrated and pyrimidifen is partitioned with n-hexane after addition of sodium chloride. The organic phase is collected and concentrated. Pyrimidifen in the organic phase is purified by silica gel column chromatography. Pyrimidifen is dissolved in acetonitrile and injected into a high-performance liquid chromatography... [Pg.1336]

Majors, R. R., High performance liquid chromatography on silica gel, Anal. Chem., 44, 1722, 1972. [Pg.50]

Cox, G. B., Loscombe, C. R., Slucutt, M. J., Sugden, K., and Upfield, J. A., The preparation, properties and some applications of bonded ion-exchange packings based on microparticulate silica gel for high-performance liquid chromatography, J. Chromatogr., 117, 269, 1976. [Pg.274]

Yamauchi, S., Nimura, N., and Kinoshita, T., Protamine-coated silica gel as packing material for high performance liquid chromatography of carbohydrates, Analyst, 118, 161, 1993. [Pg.281]

Nimura, N., Itoh, H., Kinoshita, T., Nagae, N., Nomura, M. (1991). Fast protein separation by reversed-phase high-performance liquid-chromatography on octadecylsilyl-bonded non-porous silica-gel — effect of particle-size of column packing on column efficiency. J. Chromatogr. 585(2), 207-211. [Pg.240]

Ni et al. [143] investigated the profile of the major metabolites of primaquine produced by in vitro liver microsomal metabolism, with silica gel thin-layer and high performance liquid chromatography analysis. Results indicated that the liver microsomal metabolism could simultaneously produce both 5-hydroxyprimaquine (quinoline ring oxidation product) and carboxyprimaquine (side-chain oxidative deamination product). However, the quantitative comparative study of microsomal metabolism showed that the production of 5-hydroxyprimaquine was far much higher than that of carboxyprimaquine. [Pg.201]

Ni et al. [144] also investigated the profiles of major metabolites of primaquine produced from liver microsomal and mitochondrial metabolism, in vitro by silica gel thin-layer and reversed-phase high performance liquid chromatography. The results... [Pg.201]

Thick-layer silica gel chromatography can also be employed [7], although most separations are now accomplished by high-performance liquid chromatography. Resolution of complex mixtures often requires both normal and reverse phase modes [19]. A further dimension is added, when bioactivity is correlated with spectroscopically-monitored chromatographic profiles. [Pg.44]


See other pages where High performance liquid chromatography gels is mentioned: [Pg.255]    [Pg.44]    [Pg.183]    [Pg.255]    [Pg.44]    [Pg.183]    [Pg.66]    [Pg.228]    [Pg.112]    [Pg.13]    [Pg.229]    [Pg.136]    [Pg.145]    [Pg.58]    [Pg.287]    [Pg.261]    [Pg.60]    [Pg.348]    [Pg.223]    [Pg.80]    [Pg.58]    [Pg.287]    [Pg.1130]    [Pg.1178]    [Pg.1192]    [Pg.1264]    [Pg.142]    [Pg.307]    [Pg.323]    [Pg.297]    [Pg.328]    [Pg.88]    [Pg.608]    [Pg.124]    [Pg.465]    [Pg.48]    [Pg.47]    [Pg.188]   


SEARCH



Gel-chromatography

© 2024 chempedia.info