Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

High performance liquid chromatography anionic surfactants

Jandera, P., Urbanek, J. (1995). Comparison of chromatographic behavior of oligoethylene glycol nonylphenyl ether non-ionic and anionic surfactants in reversed-phase high-performance liquid chromatography. J. Chromatogr. A 689(2), 255-267. [Pg.444]

High-performance liquid chromatography is performed using a Hewlett-Packard 1090 chromatograph equipped with a ternary-solvent delivery system, an autoinjector with a 0 -20- u.L injection loop, an oven compartment, and a diode-array UV detector. An ELS detector (Alltech Associates, Deerfield, IL) is connected in series to the UV detector. Hexane, 2-propanol, and water were used for the analysis of nonionic surfactants. Water and tetrahydrofuran (THF) are used for the analysis of anionic surfactants. No preliminary sample preparation is used other than dilution. The nonionic surfactants are diluted 1 40 (v/v) with hexane. The anionic surfactants (alkyl ether sulfates and synthetic and petroleum sulfonates) are diluted 1 20 (v/v) with water-THF (50 50). The calcium sulfonate surfactants were diluted 1 20 (v/v) with a THF-38% hydrochloric acid solution of pH 1. Hydrochloric add is required to prevent salt precipitation by converting any excess water-insoluble caldum carbonate into water-soluble calcium chloride. All diluted samples are... [Pg.1559]

The same relates to the analytical methods, where for anionic, nonionic and cationic surfactants, various colorimetric procedures (MBAS, bismuth active substance(s) (BiAS), and disulfine blue active substance(s) (DSBAS)) were introduced. Since these methods analyse only the loss of surface-activity or primary degradation, other analytical approaches have been employed in the last 10 years in order to characterize the total or ultimate degradation. These include methods such as high performance liquid chromatography (HPLC), gas chromatography (GC) GC/mass spectrometry (MS), and the measurement of total organic carbon (TOC) and chemical oxygen demand (COD). [Pg.513]


See other pages where High performance liquid chromatography anionic surfactants is mentioned: [Pg.384]    [Pg.493]    [Pg.727]    [Pg.43]    [Pg.490]    [Pg.672]    [Pg.460]    [Pg.525]    [Pg.46]   
See also in sourсe #XX -- [ Pg.90 , Pg.91 , Pg.92 , Pg.93 , Pg.94 , Pg.95 , Pg.432 , Pg.461 ]




SEARCH



Anionic surfactants

High anions

High-performance liquid chromatography surfactants

Surfactant chromatography

Surfactant performance

© 2024 chempedia.info