Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Hiac/Royco

Stream scanning Brinkmann, Glimet, Goulter, Dantec, Erdco, Faley, Flowvision, Hiac/Royco, Kowa, Lasentec, Malvern, Met One, Particle Measuring Systems, Polytec, Procedyne, Rion, Spectrex 0.2-10,000 lm O.l-lOg (also on-line)... [Pg.1582]

Air-Classification Measurement Electronic airborne particle monitoring instruments count and size particulate matter in the sampled air with no consideration of whether the particles are viable or nonviable. Air classification is defined as the number of particles per cubic foot of air that are larger than 0.5 pm in diameter. Climet and HIAC-Royco are common instruments for airborne particulate monitoring). [Pg.414]

Hiac/Royco (Nicomp instrument), Menlo Park, CA. [Pg.103]

Hiac/Royco is a division of Pacific Scientific together with Met One. Hiac manufacture a wide range of counters for liquid borne systems whereas Royco and Met One manufacture counters to monitor airborne contamination. A brief description of a selection from the Hiac range is presented below. [Pg.480]

Hiac 8012 liquid particle counting system analyzes viscous, dark, dirty fluids without dilution. The system includes the Hiac SDS (syringe driven sampler), 8000A counter and an HRLD (Hiac/Royco laser diode) sensor. [Pg.481]

Hiac/Royco 4100 series are for liquid-borne systems. Systems 4101 and 4102 are for airborne monitoring using models 1100 and 1200 airborne sensors respectively. [Pg.483]

Hiac/Royco also offer the Dynacomt laser diode sensors for sizing particles in liquids with a dynamic range of greater than 150 1 at number concentration levels up to 12000 mh. HRLD-150 covers the size range of 1 to 150 pm at particle concentrations up to 12,000 ml and flow rates from 10 to 75 ml min. HRLD-400 covers the size range of 2 to 40 pm at particle concentrations up to 8,000 ml and flow rates between 10 and 200 ml min. ... [Pg.483]

Hiac/Royco Div., Pacific Scientific, 11801 Tech Road, Silver Springs MD 20904 (301) 680 7000... [Pg.624]

Particle-measuring systems HIAC/Royco Climet... [Pg.388]

The HIAC Royco Instrument Corporation manufactures a whole range of photozone stream counters [34, 35]. The optical system used in the different instruments depends on the information requirements of the particular study. For example,... [Pg.184]

HIAC/ROYCO DIVISION OF PACIFIC SCIENTIFIC, SILVER SPRING, MARYLAND, USA... [Pg.163]

Fig. 2 HIAC/ROYCO MicroCount 05 (combined light scattering and extinction, single particle sizing sensor)... Fig. 2 HIAC/ROYCO MicroCount 05 (combined light scattering and extinction, single particle sizing sensor)...
Fig. 4 Calibration curve of a combined Scattering-Extinction sensor HIAC/ROYCO model MicroCount 05... Fig. 4 Calibration curve of a combined Scattering-Extinction sensor HIAC/ROYCO model MicroCount 05...
HIAC device.An HIAC/ROYCO model size 3000, 6 channels (Pacific Scientific Co., USA - Silver Spring, MD.) fitted with an HR60H sensor, with standard size range of 1-120 im, flow rate 10 ml min and supplied by the manifacturer already calibrated with standard spherical materials was employed. [Pg.387]

Hammatsu Corp.,120 Wood Ave., Middlesex, NJ 08846, USA Harrison Cooper Associates, Salt Lake City, Utah, USA Hawksley Sons Ltd, 12 Peter Road, Lancing, Surrey, UK Hiac/Royco Div., Pacific Scientific, 11801 Tech Road, Silver Springs MD 20904 (301)680 7000... [Pg.230]

The coacervates were analyzed using a HIAC/Royco particle sizer and an optical microscope. All coacervate samples examined by microscopy were spherical and the mean particle diameters did not change over a six hour observation period. [Pg.296]


See other pages where Hiac/Royco is mentioned: [Pg.449]    [Pg.469]    [Pg.478]    [Pg.480]    [Pg.482]    [Pg.483]    [Pg.483]    [Pg.626]    [Pg.386]    [Pg.293]    [Pg.216]    [Pg.301]    [Pg.97]    [Pg.164]    [Pg.276]    [Pg.234]    [Pg.296]   
See also in sourсe #XX -- [ Pg.468 ]




SEARCH