Generation of Heat in Electric Fields. One of the practical problems encountered in electrophoresis is the generation of heat from resistive dissipation of energy in the electrophoretic medium. The generation of heat (foule heating) is given by... [Pg.179]

One disadvantage of fluidized heds is that attrition of the catalyst can cause the generation of catalyst flnes, which are then carried over from the hed and lost from the system. This carryover of catalyst flnes sometimes necessitates cooling the reactor effluent through direct-contact heat transfer hy mixing with a cold fluid, since the fines tend to foul conventional heat exchangers. [Pg.59]

The reactor effluent might require cooling by direct heat transfer because the reaction needs to be stopped quickly, or a conventional exchanger would foul, or the reactor products are too hot or corrosive to pass to a conventional heat exchanger. The reactor product is mixed with a liquid that can be recycled, cooled product, or an inert material such as water. The liquid vaporizes partially or totally and cools the reactor effluent. Here, the reactor Teed is a cold stream, and the vapor and any liquid from the quench are hot streams. [Pg.329]

Emulsion Process. The emulsion polymerization process utilizes water as a continuous phase with the reactants suspended as microscopic particles. This low viscosity system allows facile mixing and heat transfer for control purposes. An emulsifier is generally employed to stabilize the water insoluble monomers and other reactants, and to prevent reactor fouling. With SAN the system is composed of water, monomers, chain-transfer agents for molecular weight control, emulsifiers, and initiators. Both batch and semibatch processes are employed. Copolymerization is normally carried out at 60 to 100°C to conversions of - 97%. Lower temperature polymerization can be achieved with redox-initiator systems (51). [Pg.193]

A, 5A, and 13X zeoHtes are the predorninant adsorbents for CO2 removal by temperature-swing processes. The air fed to an air separation plant must be H2O- and C02-ftee to prevent fouling of heat exchangers at cryogenic temperatures 13X is typically used here. Another appHcation for 4A-type zeoHte is for CO2 removal from baseload and peak-shaving natural gas Hquefaction faciHties. [Pg.280]

Direct Contact Heat Exchangers. In a direct contact exchanger, two fluid streams come into direct contact, exchange heat and maybe also mass, and then separate. Very high heat-transfer rates, practically no fouling, lower capital costs, and lower approach temperatures are the principal advantages. [Pg.495]

Commonly used heat-transfer surfaces are internal coils and external jackets. Coils are particularly suitable for low viscosity Hquids in combination with turbine impellers, but are unsuitable with process Hquids that foul. Jackets are more effective when using close-clearance impellers for high viscosity fluids. For jacketed vessels, wall baffles should be used with turbines if the fluid viscosity is less than 5 Pa-s (50 P). For vessels equipped with cods, wall baffles should be used if the clear space between turns is at least twice the outside diameter of the cod tubing and the fluid viscosity is less than 1 Pa-s (10... [Pg.437]

The rate of heat-transfer q through the jacket or cod heat-transfer areaM is estimated from log mean temperature difference AT by = UAAT The overall heat-transfer coefficient U depends on thermal conductivity of metal, fouling factors, and heat-transfer coefficients on service and process sides. The process side heat-transfer coefficient depends on the mixing system design (17) and can be calculated from the correlations for turbines in Figure 35a. [Pg.438]

Other energy considerations for cooling towers include the use of two-speed or variable-speed drives on cooling-tower fans, and proper cooling-water chemistry to prevent fouling in users (see Water, industrial water treatment). Air coolers can be a cost-effective alternative to cooling towers at 50—90°C, just below the level where heat recovery is economical. [Pg.93]

Cooling System Corrosion Corrosion can be defined as the destmction of a metal by chemical or electrochemical reaction with its environment. In cooling systems, corrosion causes two basic problems. The first and most obvious is the failure of equipment with the resultant cost of replacement and plant downtime. The second is decreased plant efficiency to loss of heat transfer, the result of heat exchanger fouling caused by the accumulation of corrosion products. [Pg.266]

Only trace amounts of side-chain chlorinated products are formed with suitably active catalysts. It is usually desirable to remove reactive chlorides prior to fractionation in order to niinimi2e the risk of equipment corrosion. The separation of o- and -chlorotoluenes by fractionation requires a high efficiency, isomer-separation column. The small amount of y -chlorotoluene formed in the chlorination cannot be separated by fractionation and remains in the -isomer fraction. The toluene feed should be essentially free of paraffinic impurities that may produce high boiling residues that foul heat-transfer surfaces. Trace water contamination has no effect on product composition. Steel can be used as constmction material for catalyst systems containing iron. However, glass-lined equipment is usually preferred and must be used with other catalyst systems. [Pg.54]


See other pages where Heat fouling is mentioned: [Pg.386]    [Pg.248]    [Pg.416]    [Pg.386]    [Pg.248]    [Pg.416]    [Pg.87]    [Pg.88]    [Pg.448]    [Pg.26]    [Pg.417]    [Pg.397]    [Pg.523]    [Pg.524]    [Pg.180]    [Pg.181]    [Pg.347]    [Pg.494]    [Pg.502]    [Pg.502]    [Pg.503]    [Pg.504]    [Pg.505]    [Pg.520]    [Pg.155]    [Pg.435]    [Pg.436]    [Pg.208]    [Pg.414]    [Pg.498]    [Pg.49]    [Pg.87]    [Pg.519]    [Pg.519]    [Pg.3]    [Pg.459]    [Pg.156]    [Pg.474]    [Pg.298]    [Pg.417]    [Pg.168]    [Pg.222]    [Pg.272]   