Heat transfer coefficient overall

Heat transfer based resistance theory for composite wall. The heat transfer overall coefficient is calculated. [Pg.325]

U = Overall heat transfer (fouled) coefficient. Equation 10-37... [Pg.72]

PROGRAM CALCULATES HEAT-TRANSFER FILM COEFFICIENT IN THE SHELL SIDE (BARE-TUBE) AND THE OVERALL HEAT TRANSFER COEFFICIENT OF THE HEAT EXCHANGER... [Pg.703]

The problem with Eq. (7.5) is that the overall heat transfer coefficient is not constant throughout the process. Is there some way to extend this model to deal with the individual heat transfer coefficients ... [Pg.217]

By constrast, Fig. 7.46 shows a diflFerent arrangement. Hot stream A with a low coefficient is matched with cold stream D, which also has a low coefficient but uses temperature diflferences greater than vertical separation. Hot stream B is matched with cold stream C, both with high heat transfer coefficients but with temperature differences less than vertical. This arrangement requires 1250 m of area overall, less than the vertical arrangement. [Pg.219]

Thus, for a given exchanger duty and overall heat transfer coefficient, the 1-2 design needs a larger area than the 1-1 design. However, the 1-2 design offers many practical advantages. These... [Pg.222]

Now consider the heat transfer area required by enthalpy interval k, in which the overall heat transfer coefficient is allowed to vary... [Pg.427]

Uij = overall heat transfer coefficient between hot stream i and cold stream j... [Pg.428]

The relationship between heat exchanger area and overall heat transfer coefficient U is given by... [Pg.448]

If solvent recovery is maximized by minimizing the temperature approach, the overall heat-transfer coefficient in the condenser will be reduced. This is due to the fact that a large fraction of the heat transfer area is now utilized for cooling a gas rather than condensing a Hquid. Depending on the desired temperature approach the overall heat-transfer coefficients in vent condensers usually range between 85 and 170 W/m K (ca 15 and 30 Btu/h-ft. °F). [Pg.254]

The heat-transfer coefficient of most interest is that between the bed and a wall or tube. This heat-transfer coefficient, is made up of three components. To obtain the overall dense bed-to-boiling water heat-transfer coefficient, the additional resistances of the tube wall and inside-tube-waH-to-boiling-water must be added. Generally, the conductive heat transfer from particles to the surface, the convective heat transfer... [Pg.77]

For the purpose of network synthesis, the overall heat-transfer coefficient is usually idealized as a constant value. This iadependence of the heat-transfer coefficient makes possible the iterations necessary to solve the network problem. Usually, the overall heat-transfer coefficient for each exchanger (match) is defined as... [Pg.520]

The rate of heat-transfer q through the jacket or cod heat-transfer areaM is estimated from log mean temperature difference AT by = UAAT The overall heat-transfer coefficient U depends on thermal conductivity of metal, fouling factors, and heat-transfer coefficients on service and process sides. The process side heat-transfer coefficient depends on the mixing system design (17) and can be calculated from the correlations for turbines in Figure 35a. [Pg.438]

The final correlation for the overall boiling heat-transfer coefficient in pipes or channels (20) is a direct addition of the macroscopic (mac) and microscopic (mic) contributions to the coefficient ... [Pg.96]

Overall Coefficients. Often overall coefficients of heat and mass transfer are available, rather than the film coefficients used eadier. In that case equation 35 can be rewritten as... [Pg.103]

Internal Regenerator Bed Colls. Internal cods generate high overall heat-transfer coefficients [550 W / (m -K)] and typically produce saturated steam up to 4.6 MPa (667 psi). Lower heat fluxes are attained when producing superheated steam. The tube banks are normally arranged horizontally in rows of three or four, but because of their location in a continuously active bubbling or turbulent bed, they offer limited duty flexibdity with no shutdown or start-up potential. [Pg.219]

U Overall coefficient of heat transfer for outside surface basis U for overall coefficient between liquid-vapor interface and coolant J/(s-m -K) Btu/(h-fF- F)... [Pg.551]


See other pages where Heat transfer coefficient overall is mentioned: [Pg.156]    [Pg.156]    [Pg.697]    [Pg.699]    [Pg.1369]    [Pg.88]    [Pg.124]    [Pg.48]    [Pg.216]    [Pg.217]    [Pg.222]    [Pg.448]    [Pg.479]    [Pg.254]    [Pg.77]    [Pg.128]    [Pg.482]    [Pg.485]    [Pg.486]    [Pg.486]    [Pg.488]    [Pg.500]    [Pg.520]    [Pg.520]    [Pg.520]    [Pg.528]    [Pg.355]    [Pg.208]    [Pg.244]    [Pg.474]    [Pg.477]    [Pg.477]    [Pg.547]    [Pg.551]   