Gel-permeation chromatography system

Figure 17.83 Schematic layout of gel permeation chromatography system. Figure 17.83 Schematic layout of gel permeation chromatography system.
We have prepared a copolymer-bearing amino side group and used it either alone or in combination with BP to initiate the photopolymerization of MM A [89]. The gel permeation chromatography (GPC) plot of PMMA initiated by the former system showed a bimodal distribution of molecular weight because both the radicals produced initiate polymerization as follows ... [Pg.240]

It is basically a fractionation process that depends not only on molecular size, but also on chemical composition, stereo-configuration, branching, and crosslinking. For multicomponent systems, fractionation with different ion polymolecularity, chemical heterogeneity and sequence length distribution, solubility or elution fractionation is of primary importance. Therefore, gel permeation chromatography or size exclusion chromatography is used as an important tool for the characterization of PBAs. [Pg.656]

Hie hydrolytic depolymerization of nylon-6 was followed by gel permeation chromatography (GPC), viscometry, and gravimetry. GPC determinations were performed on a Waters 150C chromatography system using benzyl alcohol as die eluant, two Plgel 10-p.m crosslinked polystyrene columns, and a differential refractometer detector. The flow rate was 1 mL/min. The concentration of the polymer solutions was 0.5 wt% and dissolution was accomplished at 130°C. [Pg.555]

High-Performance Gel Permeation Chromatography Characterization of Oligomers Used in Coatings Systems... [Pg.207]

The overall objective of the system is to map from three types of numeric input process data into, generally, one to three root causes out of the possible 300. The data available include numeric information from sensors, product-specific numeric information such as molecular weight and area under peak from gel permeation chromatography (GPC) analysis of the product, and additional information from the GPC in the form of variances in expected shapes of traces. The plant also uses univariate statistical methods for data analysis of numeric product information. [Pg.91]

Molecular Weight. Molecular weights were determined by gel permeation chromatography (GPC) on a chromatographic system consisting of a Perkin-Elmer Model 410 pump, a Waters Model 410 RI detector, and a Perkin-Elmer Model 3600... [Pg.156]

Gel permeation chromatography was performed in tetrahydrofuran using a Waters pump system and a Model 410 differential refractive index detector for the eluant. Five Ultrastyragel columns with nominal porosities ranging from 500 to 105 angstroms were used for all the samples and the polystyrene standards. [Pg.183]

Although relatively unknown, the instrumentation for 2DLC was conceived and implemented by Emi and Frei (1978). They reported the valve configuration presently used in most comprehensive 2DLC systems. However, they automated neither the valve nor the data conversion process to obtain a contour map or 2D peak display. They used a gel permeation chromatography (GPC) column in the first dimension and a reversed-phase liquid chromatography (RPLC) column in the second dimension and studied complex plant extracts. [Pg.13]

Later Rytter et al. reported possible polymer chain exchange with polypropylene produced with a combination of 8 and 11 with TMA [32], The number of stereoerrors increased in the binary system at higher TMA levels. As discussed in the case of Przybyla and Fink (vida supra), pentad analysis is less compelling evidence for reversible chain transfer. In addition, the gel permeation chromatography (GPC) data showed bimodal peaks, indicating very limited reversible transfer. [Pg.73]

A much better agreement between theory and experiment is found in the closely-related field of macrocyclisation equilibria. Investigations of the cyclic populations in ring-chain equilibrates set up in typical polymeric systems such as polyesters, polyethers, polysiloxanes, and polyamides take a major advantage from the relative ease with which the cyclic fraction can be separated from the linear fraction and analysed for the relative abundance of the individual oligomeric rings. This is conveniently done by means of modern analytical techniques such as gas-liquid and gel-permeation chromatography (Semiyen, 1976). [Pg.69]

The determination of the molecular weight of nanoparticles is performed by gel permeation chromatography (GPC). The experimental setup consists of a high performance liquid chromatography system with a size exclusion column and a refractive index detector. The nanoparticles are usually freeze-dried and dissolved in tetrahydrofuran for analysis on the system. Poly(styrene) or poly(methylmethacrylate) standards are used to calibrate the column, to enable the determination of number average molecular weight (Mn), as in... [Pg.10]


See other pages where Gel-permeation chromatography system is mentioned: [Pg.101]    [Pg.61]    [Pg.17]    [Pg.57]    [Pg.339]    [Pg.240]    [Pg.101]    [Pg.61]    [Pg.17]    [Pg.57]    [Pg.339]    [Pg.240]    [Pg.109]    [Pg.888]    [Pg.238]    [Pg.190]    [Pg.220]    [Pg.556]    [Pg.572]    [Pg.544]    [Pg.874]    [Pg.102]    [Pg.28]    [Pg.214]    [Pg.430]    [Pg.675]    [Pg.89]    [Pg.297]    [Pg.146]    [Pg.608]    [Pg.141]    [Pg.173]    [Pg.119]    [Pg.294]    [Pg.191]    [Pg.1253]    [Pg.273]    [Pg.136]    [Pg.154]    [Pg.469]    [Pg.241]    [Pg.368]   
See also in sourсe #XX -- [ Pg.101 ]