Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Gas chromatography-mass spectrometer

A qualitative comparison of the results from the gas chromatography - mass spectrometer study of the different hydrocarbons from the wood materials, did not show significant differences between results from one method to the other. As far as can be judged it is mainly the amount of each component that differs between the small scale test methods and full scale fire tests. [Pg.42]

The lncos-50 is a relatively low-cost benchtop instrument as opposed to the research grade instruments discussed earlier. The gas chromatography-mass spectrometer transfer lines allow it to be used with either the Hewlett Packard 5890 or the Varian 3400 gas chromatographs. The Incos 50 provides data system control of the gas chromatography and accessories such as autosampler or liquid sample concentration. It can be used with capillary, wide-bore or packed columns. It performs electron ionization or chemical ionization with positive or negative detection. It also accepts desorption or other solids controls. [Pg.76]

The electron impact ionization mass spectrum of cortisone acetate was obtained using solid probe introduction, using a Shimadzu QP-Class-5000 gas chromatography mass spectrometer system. The most prominent ions observed, and their relative intensities, are shown in Table 6. [Pg.196]

Watabe et al. [99] identified trace amounts of phthalate esters, polyaromatic hydrocarbons, higher fatty acids and their esters in rain water by means of a gas chromatography mass spectrometer-computer system. [Pg.401]

A gas chromatography-mass spectrometer consists of gas chromatograph, mass spectrometer and computer-based data acquisition systems. Since success... [Pg.527]

Sekiguchi, H., Matsushita, K., Yamashiro, S., Sano, Y., Seto, Y., Okuda, T., Sato, A. (2006). On-site determination of nerve gases and mustard gas using a field-portable gas chromatography-mass spectrometer. Forensic Toxicol. 24 17-22. [Pg.824]

The mass spectrum (MS) of chitin was recorded using a VG Micro-mass 7070 F gas chromatography mass spectrometer imit. The electron paramagnetic resonance (EPR) spectra were recorded using a Varian EPR spectrometer. The MS recorded at a temperature of 300 °C is shown in Eig. 2.22. This temperature was used to obtain a more stable and rich fragmentation pattern. Table 2.13 presents the list of fragments that can be attributed to the ions detected in the recorded mass spectra (MS). [Pg.63]

Kock, R. Delvoux, B. Tilhnanns, U. Greihng, H. A candidate reference method for the determination of uric acid in serum based on high-performance hquid chromatography, compared with an isotope dilution-gas chromatography-mass spectrometer method. J. Chn. Chem. Clin. Biochem. 1989, 27, 157-162. [Pg.469]

Figure 10 Gas Chromatography/Mass Spectrometer (GC/MS) of Silicone Extractables... Figure 10 Gas Chromatography/Mass Spectrometer (GC/MS) of Silicone Extractables...
Novotny, M. M.L. Lee, C.E. Low, and M.P. Maskarinec High-resolution gas chromatography/mass spectromet-ric analysis of tobacco and marijuana sterols Steroids 27 (1976) 665-673. 4836. [Pg.1448]

Preti G., Labows J., Kostelic J., Aldinger S., and Daniele R., Analysis of lung air from patients with brochogenic carcinoma and controls using gas chromatography-mass spectrometer,/. Chromatogr., 432, 1-11, 1988. [Pg.248]

Martin, C. L., Lackey, W, W., Conkle, J. P., Miller, R. L. Analysis of Trace Volatiles by Gas Chromatography/Mass Spectrometer Data System, NTIS order no. AD-A050 912, December 1977... [Pg.121]

Biller JE, Biemann K. Reconstructed mass spectra, a novel approach for the utilization of gas chromatography—mass spectrometer data. Anal Lett 1974 7 515. [Pg.716]

Gas chromatography-mass spectrometer Agilent 7890 GC/5973 MS (Agilent United States), Electric thermostatic drier (Shanghai Yuejin Medical Machinery Factory), Rotary Evaporator Model RotavaporR-200 (BUCHI), Model TurboVap II (Caliper), Ultrasonic cleaner Model KQ-700E (Kunshan Ultrasonic Instrument Co., Ltd.). [Pg.77]

Quantitative Metabolic Profiling Analysis with a Gas Chromatography -Mass Spectrometer-Computer System Koenshu - lyo Masu Kenkyukai 4 15-35 (1979) CA 92 124251b... [Pg.245]

Fig. 4.1 Schematic diagram showing the components of a computer-controlled gas chromatography-mass spectrometer (GC-MS) instrument. Fig. 4.1 Schematic diagram showing the components of a computer-controlled gas chromatography-mass spectrometer (GC-MS) instrument.
The method developed by Mari et al. (2009) consisted of solid-phase extraction by Bond Elut Certify LRC cartridges (Varian, Harbor City, CA), and derivatiza-tion of samples with BSTFA. A gas chromatography—mass spectrometer (GC—MS, Thermoquest Trace GC/Finnigan Polaris Q MS) was employed for the analysis of cocaine, benzoylecgonine, and morphine. Recoveries were higher than 87% for all the compounds and the limits of quantification were lower than 25 ng/L. [Pg.141]

Hargrove, W. F., D. Rosenthal, and P. C. Cooley Improvement of Algorithm for Peak Detection in Automatic Gas Chromatography-Mass Spectrometer Data Processing. Analyt. Chemistry 53, 538 (1981). [Pg.148]

Hutterer, F., Roboz, J., Sarkozi, L., Ruhig, A. and Bacchin, P. (1971), Gas chromatography-mass spectrometer-computer system for detection and identification of abnormal metabolic products in physiological fluids. Clin. Chem., 17, 789. [Pg.146]


See other pages where Gas chromatography-mass spectrometer is mentioned: [Pg.71]    [Pg.76]    [Pg.77]    [Pg.226]    [Pg.6]    [Pg.28]    [Pg.29]    [Pg.327]    [Pg.327]    [Pg.107]    [Pg.444]    [Pg.462]    [Pg.56]    [Pg.71]    [Pg.116]    [Pg.313]    [Pg.6]    [Pg.62]    [Pg.291]    [Pg.9]    [Pg.77]    [Pg.31]    [Pg.149]    [Pg.9]    [Pg.195]   
See also in sourсe #XX -- [ Pg.28 , Pg.29 ]




SEARCH



Gas chromatography-mass spectrometer GC-MS)

Gas spectrometer

© 2024 chempedia.info