Fourier-transform ion cyclotron resonance FTICR

Other types of mass spectrometer may use point, array, or both types of collector. The time-of-flight (TOF) instrument uses a special multichannel plate collector an ion trap can record ion arrivals either sequentially in time or all at once a Fourier-transform ion cyclotron resonance (FTICR) instrument can record ion arrivals in either time or frequency domains which are interconvertible (by the Fourier-transform technique). [Pg.201]

An added consideration is that the TOF instruments are easily and quickly calibrated. As the mass range increases again (m/z 5,000-50,000), magnetic-sector instruments (with added electric sector) and ion cyclotron resonance instruments are very effective, but their prices tend to match the increases in resolving powers. At the top end of these ranges, masses of several million have been analyzed by using Fourier-transform ion cyclotron resonance (FTICR) instruments, but such measurements tend to be isolated rather than targets that can be achieved in everyday use. [Pg.281]

To check the identity and purity of the products obtained in the above reactions it is not sufficient to analyze for the sulfur content since a mixture may incidentally have the same S content. Either X-ray diffraction on single crystals or Raman spectra of powder-like or crystalline samples will help to identify the anion(s) present in the product. However, the most convincing information comes from laser desorption Fourier transform ion cyclotron resonance (FTICR) mass spectra in the negative ion mode (LD mass spectra). It has been demonstrated that pure samples of K2S3 and K2S5 show peaks originating from S radical anions which are of the same size as the dianions in the particular sample no fragment ions of this type were observed [28]. [Pg.132]

Resolution does not affect the accuracy of the individual accurate mass measurements when no separation problem exists. When performing accurate mass measurements on a given component in a mixture, it may be necessary to raise the resolution of the mass spectrometer wherever possible. Atomic composition mass spectrometry (AC-MS) is a powerful technique for chemical structure identification or confirmation, which requires double-focusing magnetic, Fourier-transform ion-cyclotron resonance (FTICR) or else ToF-MS spectrometers, and use of a suitable reference material. The most common reference materials for accurate mass measurements are perfluorokerosene (PFK), perfluorotetrabutylamine (PFTBA) and decafluorotriph-enylphosphine (DFTPP). One of the difficulties of high-mass MS is the lack of suitable calibration standards. Reference inlets to the ion source facilitate exact mass measurement. When appropriately calibrated, ToF mass... [Pg.356]

Currently PCR and mass spectrometry are performed by two separate instruments. However, there is no reason why PCR followed by simple automated cleanup and mass spectrometry cannot be incorporated into a single integrated instrument. Essentially every configuration of the modern ESI mass spectrometer has been used successfully for the analysis of PCR products, from the highest to the lowest resolution involving. Fourier transform ion cyclotron resonance (FTICR), triple quadrupole, quadrupole-time of flight (Q-TOF), and ion trap.22-24 MS discriminates between two structurally related PCR products by MW difference. Mass accuracy is needed to differentiate the... [Pg.28]

Mass analyzers interrogate and resolve ions produced by an ion source based on their m/z ratios. Several types of mass analyzers are utilized for proteomic analysis including time-of-flight (TOF) quadrupoles, ion traps, and Fourier transform ion cyclotron resonance (FTICR). Mass analyzers may be assembled in hybrid configurations. MS instruments such as quadrupole TOF and quadra-pole ion trap-FTICR facilitate diversified applications and achieved great success. [Pg.381]

Ion detection is carried out using image current detection with subsequent Fourier transform of the time-domain signal in the same way as for the Fourier transform ion cyclotron resonance (FTICR) analyzer (see Section 2.2.6). Because frequency can be measured very precisely, high m/z separation can be attained. Here, the axial frequency is measured, since it is independent to the first order on energy and spatial spread of the ions. Since the orbitrap, contrary to the other mass analyzers described, is a recent invention, not many variations of the instrument exist. Apart from Thermo Fischer Scientific s commercial instrument, there is the earlier setup described in References 245 to 247. [Pg.57]

Figure 2.19. Schematic of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (a) and a cylindrical cell (b). Reprinted from A. Westman-Brinkmalm and G. Brinkmalm (2002). In Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research, J. Silberring and R. Ekman (eds.) New York John Wiley Sons, 47-105. With... Figure 2.19. Schematic of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (a) and a cylindrical cell (b). Reprinted from A. Westman-Brinkmalm and G. Brinkmalm (2002). In Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research, J. Silberring and R. Ekman (eds.) New York John Wiley Sons, 47-105. With...
Fourier transform ion cyclotron resonance (FTICR) analyzer is excellent for MSn measurements (see Section 2.2.6), perhaps even more so, since the ions remain in the cell after detection. In principle one injection of ions is enough for a whole MSn sequence, including acquisition of a mass spectrum of each step. [Pg.96]

In addition to the diversity of ionisation techniques available, mass spectrometers offer a selection of mass analyser configurations. Of note are single (MS) and triple quadrupole (MS—MS) instruments, ion trap analysers (MS)n, time-of-flight (ToF) analysers, sector field analysers, and Fourier transform-ion cyclotron resonance (FTICR) instruments. [Pg.147]

An overview of commercial ICP mass spectrometers from different companies (quadrupole based ICP-MS with and without collision/reaction cell, double-focusing sector field instrumentation with single and multiple ion collectors, time-of-flight (ToF), ICP-ion trap-MS and non-commercial ICP-Fourier transform ion cyclotron resonance (FTICR) mass spectrometers is given in Figure 5.2. By using ion traps and FTICR mass spectrometers in ICP-MS isobaric interferences of atomic ions... [Pg.120]

The most common types of MS/MS instruments available to researchers in food chemistry include triple quadrupole mass spectrometers and ion traps. Less common but commercially produced tandem mass spectrometers include magnetic sector instruments, Fourier transform ion cyclotron resonance (FTICR) mass spectrometers, and quadrupole time-of-flight (QTOF) hybrid instruments (Table A.3A.1). Beginning in 2001, TOF-TOF tandem mass spectrometers became available from instrument manufacturers. These instruments have the potential to deliver high-resolution tandem mass spectra with high speed and should be compatible with the chip-based chromatography systems now under development. [Pg.1328]

The gas-phase basicity (GB) of 3-thio-5-oxo 1, 5-thio-3-oxo 2, and 3,5-dithio 4 derivatives of 2,7-dimethyl-[l,2,4]-triazepine (Figure 1) has been measured by means of Fourier transform ion cyclotron resonance (FTICR) mass spectrometry and complemented with theoretical calculations. The experimental FTICR results are discussed in Section 13.14.4.1.l(i). The structures and vibrational frequencies of all stable protonated tautomers and all transition states connecting them have been obtained by means of the B3LPY density functional method, together with 6-31G basis set expansion. The final energies were obtained at the B3LYP/6-311 + G(3df,-2p) level (2002JPC7383). [Pg.402]

Reemtsma,T.,These, A., Springer, A., and Linscheid, M. (2008). Differences in the molecular composition of fulvic acid size fractions detected by size-exclusion chromatography—On fine Fourier transform ion cyclotron resonance (FTICR-) mass spectrometry. Water Res. 42, 63-72. [Pg.403]

Many heterocycles, for instance NH-azoles, have acid-base properties of either or both proton gain (basicity) and proton loss (acidity) [85], The possibility of studying such processes in the gas-phase (mass spectrometry and Fourier transform ion cyclotron resonance - FTICR - spectroscopy) provides theoreticians with values... [Pg.164]

The technique of laser desorption (LD) has been widely used in mass spectrometry (J, 2) to desorb and to ionize high molecular weight or other nonvolatile samples, most often using time-of-flight (3. 4 ) or Fourier transform ion cyclotron resonance (FTICR) ( 5. 6 ) mass spectrometers for mass analysis. In this technique, highly focussed laser irradiation, most often with a power density of at least 10° W/cm, is used to desorb and ionize a solid sample that has been inserted into the high vacuum system of the mass spectrometer. [Pg.140]

In a commercially available device based on Penning traps - the Fourier transform ion cyclotron resonance (FTICR) mass spectrometer - the ions are constrained spatially or rather ions can be... [Pg.95]

Ion-molecular reactions are used to resolve isobaric interferences, as discussed, in ICP-MS with a collision/reaction cell or by utilizing ion traps. The mass spectra of Sr, Y and Zr (Fig. 6.10a) without O2 admitted into the collision cell and (Fig. 6.10b) with 10 Pa Oj are different. By introducing oxygen, selective formation of YO and ZrO, but not SrO, is observed. This behaviour of different oxide formation is relevant for an interference free determination of Sr. Ultrahigh mass resolving power ICP mass spectrometry (at m/Am 260 000) selectively removes unwanted ions prior to transfer to the FTICR analyzer cell by gas-phase chemical reactions, e.g., for separation of Ca from " Ar+ obtained with a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer equipped with a 3 tesla superconducting magnet. ... [Pg.187]

Modes of MS ionization are El, Cl, FAB, PDI, MALDI and ESI and major MS analysers include time-of-llight (TOE) quadmpole ion-trap (QIT) Fourier transform ion cyclotron resonance (FTICR) and orbitrap. [Pg.198]


See other pages where Fourier-transform ion cyclotron resonance FTICR is mentioned: [Pg.189]    [Pg.395]    [Pg.16]    [Pg.38]    [Pg.38]    [Pg.244]    [Pg.665]    [Pg.547]    [Pg.42]    [Pg.88]    [Pg.187]    [Pg.355]    [Pg.18]    [Pg.398]    [Pg.435]    [Pg.92]    [Pg.404]    [Pg.250]    [Pg.355]    [Pg.65]   
See also in sourсe #XX -- [ Pg.38 , Pg.57 , Pg.96 ]

See also in sourсe #XX -- [ Pg.18 ]

See also in sourсe #XX -- [ Pg.138 , Pg.206 ]

See also in sourсe #XX -- [ Pg.9 ]

See also in sourсe #XX -- [ Pg.3 , Pg.4 , Pg.16 , Pg.78 ]

See also in sourсe #XX -- [ Pg.23 ]