Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Flight-essential

Flight essential refers to the subset of equipment and assets necessary for continued flight and landing of an aircraft or air vehicle. Typically, this subset of equipment applies to normal operation (i.e., no failures) and is therefore larger than the subset of equipment designated as flight critical. [Pg.161]

Another form of array is called a microchannel plate detector. A time-of-flight (TOP) mass spectrometer collects ions sequentially in time and can use a point detector, but increasingly, the TOP instrument uses a microchannel plate, most particularly in an orthogonal TOP mode. Because the arrays and microchannel plates are both essentially arrays or assemblies of small electron multipliers, there may be confusion over their roles. This chapter illustrates the differences between the two arrays. [Pg.213]

Isotope shifts for most elements are small in comparison with the bandwidth of the pulsed lasers used in resonance ionization experiments, and thus all the isotopes of the analyte will be essentially resonant with the laser. In this case, isotopic analysis is achieved with a mass spectrometer. Time-of flight mass spectrometers are especially well-suited for isotopic analysis of ions produced by pulsed resonance ionization lasers, because all the ions are detected on each pulse. [Pg.135]

Since 1950, plastics have been development for uses in very high temperature environments. By 1954, it was demonstrated that plastic materials were suitable for thermally protecting structures during intense propulsion heating. This discovery, at that time, became one of the greatest achievements of modern times, because it essentially initially eliminated the thermal barrier to hypersonic atmospheric flight as well as many of the internal heating problems associated with chemical propulsion systems. [Pg.118]

Tandem mass spectrometry (MS/MS) is a method for obtaining sequence and structural information by measurement of the mass-to-charge ratios of ionized molecules before and after dissociation reactions within a mass spectrometer which consists essentially of two mass spectrometers in tandem. In the first step, precursor ions are selected for further fragmentation by energy impact and interaction with a collision gas. The generated product ions can be analyzed by a second scan step. MS/MS measurements of peptides can be performed using electrospray or matrix-assisted laser desorption/ionization in combination with triple quadruple, ion trap, quadrupole-TOF (time-of-flight), TOF-TOF or ion cyclotron resonance MS. Tandem... [Pg.1191]

Considering these situations, the observation of molecular weights, particularly by matrix-assisted laser desorption/ionization time-of-flight mass spectroscopy (MALDI-TOF MASS), is essential [33]. The operation is simple and enables us to observe the molecular ion peaks of CPOs with molecular weights exceeding 10,000. The quahty of the measurement is strongly dependent on the choice of the matrix. Therefore, the search for the best matrix for each CPO should be pursued. [Pg.80]

Aircraft toilet sanitisers may come into contact with a variety of different materials through spillage and leakage and therefore materials testing is essential on neat and diluted sanitiser solutions. Problems have occurred in the past where electrical connectors have been short-circuited by leakage in the toilet area and caused loss of aircraft trim during flight. A typical list of materials tested is shown below ... [Pg.122]

A position sensitive detector (PSD) is employed, of which there are several types used effectively around the world. One type is essentially a square array of multianodes, as shown in Figure 1.6. By measuring the time-of-flight and the coordinates of the ions upon the PSD, it is possible to map out a two-dimensional elemental distribution. The elemental maps are extended to the z-direction by ionizing atoms from the surface of the specimens. The z position is inferred from the position of the ion in the evaporation sequence, so that the atom distribution can be reconstructed in a three-dimensional real space. [Pg.10]

Currently PCR and mass spectrometry are performed by two separate instruments. However, there is no reason why PCR followed by simple automated cleanup and mass spectrometry cannot be incorporated into a single integrated instrument. Essentially every configuration of the modern ESI mass spectrometer has been used successfully for the analysis of PCR products, from the highest to the lowest resolution involving. Fourier transform ion cyclotron resonance (FTICR), triple quadrupole, quadrupole-time of flight (Q-TOF), and ion trap.22-24 MS discriminates between two structurally related PCR products by MW difference. Mass accuracy is needed to differentiate the... [Pg.28]

It should be noted that the dynamic conditions of droplet impact processes discussed above cover a large range of the actual conditions in many industrial processes, such as spray forming, thermal spray, spray combustion, spray cooling, and aircraft flight. Under these conditions, the spreading behavior of droplets on a flat surface is essentially governed by inertia and viscous effects (Fig. [Pg.198]


See other pages where Flight-essential is mentioned: [Pg.161]    [Pg.161]    [Pg.161]    [Pg.161]    [Pg.725]    [Pg.2060]    [Pg.190]    [Pg.205]    [Pg.206]    [Pg.2]    [Pg.428]    [Pg.307]    [Pg.409]    [Pg.485]    [Pg.109]    [Pg.42]    [Pg.329]    [Pg.61]    [Pg.103]    [Pg.337]    [Pg.204]    [Pg.339]    [Pg.390]    [Pg.150]    [Pg.340]    [Pg.510]    [Pg.42]    [Pg.183]    [Pg.103]    [Pg.427]    [Pg.440]    [Pg.213]    [Pg.182]    [Pg.45]    [Pg.209]    [Pg.21]    [Pg.230]    [Pg.924]    [Pg.201]    [Pg.239]    [Pg.380]   
See also in sourсe #XX -- [ Pg.161 ]




SEARCH



© 2024 chempedia.info