Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Filter paper, using

Bacharach smoke scale A scale of 10 shades of white to black for a smoke stain formed in a prescribed manner by a pumping action through a filter paper, used for the assessment of smoke from combustion appliances. [Pg.1416]

Dining examination of a 10 g batch of the crystalline material on a filter paper using a hand lens, it exploded. This was attributed to sudden rearrangement of the... [Pg.707]

Acidifying the sample causes colloids and fine sediments that passed through the filter to gradually dissolve, yielding abnormally high concentrations of elements such as aluminum, iron, silicon, and titanium when the fluid is analyzed. Figure 6.4, from a study of this problem by Kennedy et al. (1974), shows how the pore size of the filter paper used during sample collection affects the concentrations determined for aluminum and iron. [Pg.95]

Fig. 6.4. Effects of the pore size of filter paper used during fluid sampling on the analytical concentrations reported for aluminum and iron (Kennedy el al., 1974). Samples were acidified, stored for 19 ( ) or 94 ( ) days, and analyzed by standard wet chemical methods. Dotted lines show dissolved concentrations determined by a solvent extraction technique. Fig. 6.4. Effects of the pore size of filter paper used during fluid sampling on the analytical concentrations reported for aluminum and iron (Kennedy el al., 1974). Samples were acidified, stored for 19 ( ) or 94 ( ) days, and analyzed by standard wet chemical methods. Dotted lines show dissolved concentrations determined by a solvent extraction technique.
The soil samples are air dried. Transfer 50g into a 500ml flat-bottomed flask and extracted with methanol. Remove the methanol by using a rotary evaporator with a water bath at 55°C. Cool the flask and add 5.0ml of methanol, swirl to dissolve the residue and filter the solution through a Whatman No. 42 filter-paper. Using a flow-rate of 0.6ml min-1, inject 5pl of extract into the liquid chromatograph. Calculate the uron content of the sample by comparing the peak height obtained with those obtained from 5pl injections of standard solutions. [Pg.249]

Finish the experiment as directed in Experiment 6, steps 13 and 14. Slowly dry the filter paper using a Bunsen burner. Heat until black. Then incline the crucible at an angle, Hd ajar, and direct the flame of a Meker burner to the bottom of the crucible, allowing air to get inside the crucible (Figure 3.9). Apply the full heat of the Meker burner for 20 min, or if only one Meker burner is available, alternate, as before, with a Bunsen burner for V2 h. Cool and weigh. Calculate the percent Fe in the sample. The precipitate is Fe203. [Pg.60]

What does it mean to say that a filter paper is ashless If the filter paper used in Experiments 6 and 7 were not ashless, what specific effect would it have on the calculated results ... [Pg.63]

Another problem encountered was the impurity content of the filter paper used in the high volume samplers to collect the particulate samples. The conventional filter material used by EPA was glass fiber filter media. However, this was not compatible with INAA because of its high and varied impurity content. Discussions with K. Rahn of the Ford Reactor at the University of Michigan revealed that Whatman-41 filter paper was the most desirable medium for use with INAA (see Ref. 2). Our analyses showed Whatman-41 to be very low in impurities with consistent impurity levels from batch to batch. Average impurity levels, based on 12 batch analyses, are shown in Table III. Although the levels for calcium, chlorine, sodium, aluminum, and iron appear large, they rarely affected elemental levels found in filtered particulates. Impurity levels did not vary more than 25% from the mean. [Pg.113]

The filter paper is supported by a glass frit clamped between two glass tubes. The precipitate is washed finally with acetone or alcohol to dry it. The precipitate is chosen to have a known stoichiometry to allow calculation of the yield of the separation and should not absorb water or CO2 so that an accurate weight can be obtained. (The filter paper used in the filtration must be treated with all the reagents beforehand, dried, and weighed so that any material loss in filtration is minimized.)... [Pg.596]

Mix beet puree with an equal amount of filter aid (celite), quantitatively transfer to a Buchner funnel, and filter through Whatman no. 1 filter paper using reduced pressure. [Pg.895]

Fold the filter paper to fit the funnel, set up the funnel for filtering, and pour the combination of the solutions into the filter paper. Use a 100 ml beaker to collect the filtrate. [Pg.108]

Figure 2. Dependence of fold endurance on percentage weight gain for Whatmans filter paper using EA MMA 5 1. Figure 2. Dependence of fold endurance on percentage weight gain for Whatmans filter paper using EA MMA 5 1.
Laboratory filter paper used in modem labs is usually circular in nature, so fluting the paper is necessary. Fluted filter paper is superior to flat filter paper because fluted filter paper allows for better airflow between the funnel wall and the fluted filter paper. [Pg.19]

After the application of the Reinsch Test, filter the sample and retain the solids and the filter paper. Use small aliquots of the filtrate to test for borate (p. 64), and phosphate. [Pg.50]

Filter the recrystallization solution through the filter paper using hand protection (rubber fingers or an insulated glove) and keep the filter topped up with solution to prevent cooling. At the same time. [Pg.97]

Many effluent permit limitations also include total suspended solids (TSS). The test procedure for TSS also measures oil and grease that is removed in the filter paper used in the test. Non-oil-suspended solids are normally low in vegetable oil handling wastewaters therefore, the parameter is not really of significance in most applications. There are some exceptions, such as milling and extraction area wastes along with salad dressing and mayonnaise. [Pg.2391]

Why is a fluted filter paper used in gravity filtration ... [Pg.44]

In a mortar, grind two Extra Strength Excedrin tablets to a very fine powder. The label states that this analgesic contains 250 mg of aspirin, 250 mg of acetaminophen, and 65 mg of caffeine per tablet. Place this powder in a test tube and add to it 7.5 mL of dichloromethane. Warm the mixture briefly and note that a large part of the material does not dissolve. Filter the mixture into another test tube. This can be done by transferring the slurry to a funnel equipped with a piece of filter paper. Use a Pasteur pipette and complete the transfer with a small portion of dichloromethane. This filtrate is Solution 1. [Pg.190]

What factors could account for inaccurate or imprecise data Perhaps Student A did not follow the procedure with consistency. He or she might not have read the graduated cylinder at eye level for each trial. Student C may have made the same slight error with each trial. Perhaps he or she included the mass of the filter paper used to protect the balance pan. Student B may have recorded the wrong data or made a mistake when dividing the mass by the volume. External conditions such as temperature and humidity also can affect the collection of data. [Pg.37]

In the case of °Y labelling, quality controls were performed by paper chromatography (Whatman No. 3 filter paper), using saline as the mobile phase. Ahquots were spotted on chromatographic paper and allowed to migrate 10-12 cm from the origin. [Pg.57]

After the reaction is over filter the suspension through Whatman No 40 filter paper using suction. [Pg.37]

Potassium dihydrogen phosphate [7778-77-0] M 136.1. Dissolve it in boiling distilled water (2mL/g), keep on a boiling water-bath for several hours, then filter it through paper pulp to remove any turbidity. Cool rapidly with constant stirring, and the crystals are collected on to hardened filter paper, using suction, washed twice with ice-cold water, once with 50% EtOH, and dried at 105°. Alternative crystallisations are from water, then 50% EtOH, and again water, or from concentrated aqueous solution by addition of EtOH. It... [Pg.483]

Carefully transfer the mixture, including all of the precipitate, from the beaker to the filter paper, using a stirring rod and a wash bottle as demonstrated by your teacher. [Pg.423]

Filter Papers used in this study were obtained from Advantec Co. (Japan) and the milk powder is the product of Morinaga Milk Industry Co. (Japan). [Pg.147]

What did you observe about the filter paper used with the red unknown water mixture About the dish ... [Pg.74]


See other pages where Filter paper, using is mentioned: [Pg.244]    [Pg.454]    [Pg.116]    [Pg.393]    [Pg.381]    [Pg.37]    [Pg.413]    [Pg.413]    [Pg.503]    [Pg.245]    [Pg.328]    [Pg.40]    [Pg.91]    [Pg.478]    [Pg.538]    [Pg.58]    [Pg.39]    [Pg.454]    [Pg.996]    [Pg.465]   
See also in sourсe #XX -- [ Pg.25 ]




SEARCH



Filter paper

Use for Filtering Paper