Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

File size

The raw data table is displayed with the numbers on a white background and the headers and index on a gray one a yellow How-to-Procede panel gives instructions, respectively confirms choices two white panels display the file size and the presently selected rounding option. [Pg.363]

Another data acquisition consideration is data file size. A high speed LC/MS data file can easily reach dimensions of 20 MB/min if maximal information is required and the detectors are set to broadest scan ranges and highest sampling rates without data reduction. LC/MS systems capable... [Pg.107]

Average Data File Size based on Detector Technology... [Pg.598]

Detector 1 Samplinq Rate Run Time Data File Size... [Pg.598]

FIGURE 9 The impact of detector technology on data file size. [Pg.598]

Spencer RW. (1998) High-throughput screening of historic collections Observations on file size, biological targets and file diversity. Biotechnol. Bioeng. 61 61-67. [Pg.29]

Although we have made use of SD files up to this point, at this stage we switch to SMILES files (19). This becomes necessary because even for small libraries the file size for a fully enumerated set can be quite large. For example, a sample library of just 2500 compounds resulted in 4.85 MB SD file while the SMILES file was only 384 KB. The one caveat with the SMILES format is that there is no standard for handling data fields. Our solution was to reformat the SD file type data field tags into the SMILES file,... [Pg.81]

Computer workstation and associated software capable of handling large file sizes (see Note 2). [Pg.225]

Average daily tcpdump file size 1.5 Mbytes... [Pg.234]

Average daily dump file size 114 Kbytes... [Pg.235]

Folder/directory structures File structures File sizes File properties File access Storage media Storage capacity Data retrieval rates User interfaces... [Pg.717]

If files are offered for download, is the file size displayed ... [Pg.906]

An essential application of the Internet is exchanging data. The most important validation task is to verify correct data transfer when uploading and downloading files to the Web server and for e-mail communication. Correct file data transfer should be tested not only under normal but also high load conditions. Test variables should include Web browser, time of day, location of destination computer, and file size. For verification of correct file transfer we can use hash calculations, which are also used for digital signatures. Important is development of specifications, for example, maximum file size. [Pg.906]

We should mention, too, that you can build different parts or prototypes during the same machine run. Such variety can be programmed into the machine, and the operator can set the machine up for such varied output. As long as your job doesn t exceed the working space limits and STL file-size limits, you can run as many parts with as many designs as you want. [Pg.259]

The depalletizer in a packaging line accepts stacked bottles on pallets that have dividers and discharges one container at a time in single file. Sizing of the depalletizer for unsorted containers must be analyzed with respect to the product mix ratios, type and speed of the filler, and the condition of the pallets, conveyors, and containers. [Pg.2660]

Finding specific files This is accessed under View > Find in Windows 98 or by using the Search button in Windows 2000. Either way, you can search for files based on their name, file size, file type, and other attributes, as shown in Figure 12.25. [Pg.500]

Test cases reflect typical user applications with manual interactive and automated operation. Automated sequences typically run over 24 h or more, where methods are changed between runs. Data files with different file sizes are generated to make sure that system can handle large files. [Pg.29]

Perhaps the biggest liability with the TOF analyzers is the very large volume of data collected during LC-MS analysis. The large file size is not practical in rapid applications. Processing speed and archival of the large amounts of collected data must be addressed before the LC-TOF instruments will be of practical use in routine-discovery metabolism applications. [Pg.268]

Compactness. Given the size of today s databases and the requirement to store hundreds of conformers per molecule, compactness of storage becomes an issue with respect to both file size and retrieval efficiency. [Pg.154]

Analyte detection in all these methods involved an ultraviolet diode array detector over the range 214-216 nm to minimize data file size. Mass spectrometric data were obtained following a split of the HPLC solvent stream of approximately 100 1. The mass spectrometer was tuned for optimal sensitivity and unit mass resolution. The mass range 180-800 daltons... [Pg.796]


See other pages where File size is mentioned: [Pg.103]    [Pg.107]    [Pg.114]    [Pg.114]    [Pg.111]    [Pg.173]    [Pg.197]    [Pg.223]    [Pg.230]    [Pg.57]    [Pg.31]    [Pg.103]    [Pg.234]    [Pg.235]    [Pg.134]    [Pg.401]    [Pg.256]    [Pg.43]    [Pg.48]    [Pg.331]    [Pg.179]    [Pg.72]    [Pg.696]    [Pg.796]    [Pg.796]    [Pg.455]   