Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fast atom bombardment FAB

A big step forward came with the discovery that bombardment of a liquid target surface by abeam of fast atoms caused continuous desorption of ions that were characteristic of the liquid. Where this liquid consisted of a sample substance dissolved in a solvent of low volatility (a matrix), both positive and negative molecular or quasi-molecular ions characteristic of the sample were produced. The process quickly became known by the acronym FAB (fast-atom bombardment) and for its then-fabulous results on substances that had hitherto proved intractable. Later, it was found that a primary incident beam of fast ions could be used instead, and a more generally descriptive term, LSIMS (liquid secondary ion mass spectrometry) has come into use. However, note that purists still regard and refer to both FAB and LSIMS as simply facets of the original SIMS. In practice, any of the acronyms can be used, but FAB and LSIMS are more descriptive when referring to the primary atom or ion beam. [Pg.17]

El = electron ionization. Cl = chemical ionization TSP = thermospray FAB = fast atom bombardment FD = field desorption,... [Pg.539]

FAB Fast atom bombardment FTMS Fourier-transform mass spectrometry... [Pg.754]

Other MS based analytical approaches have occasionally been applied to ancient resin samples, in particular for paint varnishes. Such techniques include FABS (fast atom bombardment mass spectrometry) [35], MALDI (matrix assisted laser desorption-ionization mass spectrometry) and GALDI (graphite assisted laser desorption-ionization mass spectrometry) [36 38]. [Pg.218]

Figure 14.1 Schematic view of a mass spectrometer. Its basic parts are ion source, mass analyzer, and detector. Selected principles realized in modern mass spectrometers are assigned El—electron impact. Cl—chemical ionization, FAB—fast atom bombardment, ESI—electrospray ionization, MALDI—matrix-assisted laser desorption/ionization. Different combinations of ion formation with mass separation can be realized. Figure 14.1 Schematic view of a mass spectrometer. Its basic parts are ion source, mass analyzer, and detector. Selected principles realized in modern mass spectrometers are assigned El—electron impact. Cl—chemical ionization, FAB—fast atom bombardment, ESI—electrospray ionization, MALDI—matrix-assisted laser desorption/ionization. Different combinations of ion formation with mass separation can be realized.
Figure A.3A.1 Flow chart illustrating the selection of a suitable ionization technique for the mass spectrometric analysis of a sample. Abbreviations APCI, atmospheric pressure chemical ionization Cl, chemical ionization El, electron impact FAB, fast atom bombardment MALDI, matrix-assisted laser desorption/ionization. Figure A.3A.1 Flow chart illustrating the selection of a suitable ionization technique for the mass spectrometric analysis of a sample. Abbreviations APCI, atmospheric pressure chemical ionization Cl, chemical ionization El, electron impact FAB, fast atom bombardment MALDI, matrix-assisted laser desorption/ionization.
Notes LOD, limit of detection MeOH, methanol EtOH, ethanol ACN, acetonitrile MTBE, methyl tert-butyl ether DCM, dichloromethane THF, tetrahy-drofuran KOH, potassium hydroxide SFE, supercritical fluid extraction MS, mass spectrometry HPLC, high-performance liquid chromatography DAD, diode array detector PDA, photodiode array detector FD, fluorescence detector ECD, electrochemical detector ESI, electrospray ionization APCI, atmosphere pressure chemical ionization TLC, thin layer chromatography FAB, fast atom bombardment NMR, nuclear magnetic resonance BHT, butylated hydroxytoluene SPE, solid phase extraction. [Pg.67]

Fig. 5 Statistical evaluation of LC-MS-based methods for tropane alkaloids referred in this chapter. (a) Relative frequency of ionization methods. +APCI positive atmospheric pressure chemical ionization, +ESI positive electrospray ionization, FAB fast atom bombardment, +TSP positive thermospray, (b) Relative frequency of scan modes used. MS full scan MS, MS/MS tandem mass spectrometry (product ion scan), MRM multiple reaction monitoring, SIM selected ion monitoring, (c) Relative frequency of mass analysers used. EBQtQ2 double focusing sector field mass spectrometer, IT ion trap, QqQ triple quadrupole, SQ single quadrupole. Considered publications were found by PubMed data-based search and references cited in these articles... Fig. 5 Statistical evaluation of LC-MS-based methods for tropane alkaloids referred in this chapter. (a) Relative frequency of ionization methods. +APCI positive atmospheric pressure chemical ionization, +ESI positive electrospray ionization, FAB fast atom bombardment, +TSP positive thermospray, (b) Relative frequency of scan modes used. MS full scan MS, MS/MS tandem mass spectrometry (product ion scan), MRM multiple reaction monitoring, SIM selected ion monitoring, (c) Relative frequency of mass analysers used. EBQtQ2 double focusing sector field mass spectrometer, IT ion trap, QqQ triple quadrupole, SQ single quadrupole. Considered publications were found by PubMed data-based search and references cited in these articles...
There are several types of ionization sources [MALDI, ESI, FAB (fast atom bombardment), PD (Cf-252 plasma desorption), El (electron ionization), Cl (chemical ionization) etc.], different types of mass analyzers [combinations of magnetic and electric sectors, quadrupolar filters (Q) and ion traps (IT), time-of-flight (TOF) and FT-ICR] and different detectors, each with its own advantages and drawbacks. We describe herein only the systems that presently have widespread use for the study of biomolecules ESI coupled to a quadrupole (or triple quadrupole, QqQ) mass analyzer or an ion trap, the MALDI source with the linear or reflectron TOF analyzer, and the FT-ICR system which can be equipped with both ESI and MALDI sources. [Pg.301]

Recently, the enantiomeric excess of a-amino acid ester hydrochlorides has been determined directly by using FAB (fast atom bombardment) mass spectrometry without chromatographic separation of the enantiomers. ... [Pg.15]

Besides X-ray crystallography, NMR and mass spectrometry are the two principal methods used for identifying taxanes. For instance, the proton-NMR spectra constitute a good fingerprinting of the substitutions present on the skeleton, as has been shown in Miller s excellent review of the NMR of taxane-type derivatives (76). Carbon-13 NMR has also been applied to the specific study of taxanes having an epoxide or oxetane functionality (77). As for mass spectrometry, only chemical ionization (for the various fragmentations) or FAB (fast-atom bombardment for the molecular weight) may be used for structural resolutions. Circular... [Pg.197]

Fig. 1 Schematic representation of a mass spectrometer depicting its main components and the different modes used. Abbreviations DIP direct insertion probe DEP direct exposure probe GC gas chromatography LC liquid chromatography CE capillary chromatography TEC thin-layer chromatography FEE field-flow fractionation APCI atmospheric pressure ionization El electron impact Cl chemical ionization FAB fast-atom bombardment PD plasma desorption MALDI matrix-assisted laser desorption ionization ED laser desorption TSP thermospray ESI electron spray ionization HSI hypherthermal surface ionization Q quadropole QQQ triple quadropole TOE time-of-fiight FTMS Fourier transform mass spectrometer IT ion trap EM electrom multiplier PM photomultiplier ICR ion cyclotron resonance. Fig. 1 Schematic representation of a mass spectrometer depicting its main components and the different modes used. Abbreviations DIP direct insertion probe DEP direct exposure probe GC gas chromatography LC liquid chromatography CE capillary chromatography TEC thin-layer chromatography FEE field-flow fractionation APCI atmospheric pressure ionization El electron impact Cl chemical ionization FAB fast-atom bombardment PD plasma desorption MALDI matrix-assisted laser desorption ionization ED laser desorption TSP thermospray ESI electron spray ionization HSI hypherthermal surface ionization Q quadropole QQQ triple quadropole TOE time-of-fiight FTMS Fourier transform mass spectrometer IT ion trap EM electrom multiplier PM photomultiplier ICR ion cyclotron resonance.
Hepatotoxins were isolated as new hepatotoxic compounds from the cyanobacterium Nostoc sp. strain 152 and assigned structures based on their high resolution FAB (fast atom bombardment) MS/MS, H and C NMR spectra, amino acid analysis and gas chromatography on a chiral capillary column by Namikoshi et al ... [Pg.744]


See other pages where Fast atom bombardment FAB is mentioned: [Pg.445]    [Pg.483]    [Pg.212]    [Pg.123]    [Pg.293]    [Pg.206]    [Pg.150]    [Pg.73]    [Pg.619]    [Pg.187]    [Pg.117]    [Pg.164]    [Pg.998]    [Pg.196]    [Pg.435]    [Pg.121]    [Pg.23]    [Pg.728]    [Pg.194]    [Pg.288]    [Pg.317]    [Pg.443]    [Pg.98]    [Pg.116]    [Pg.219]    [Pg.8]    [Pg.13]    [Pg.470]    [Pg.614]    [Pg.445]   


SEARCH



Bombardment

Continuous-flow fast atom bombardment CF-FAB)

FAB

Fast Atom Bombardment (FAB) and Liquid-matrix Secondary Ion Mass Spectrometry (LSIMS)

Fast atom

Fast atom bombardment (FAB) and liquid secondary ion mass spectrometry (LSIMS)

Fast atom bombardment CF-FAB

Fast atom bombardment mass spectrometry FAB-MS)

Fast atom bombardment mass spectroscopy FAB-MS)

Fast atomic bombardment

Fast-atom bombardment

© 2024 chempedia.info