Exhaustion disturbance

Vacuum is applied to the chamber and vapor is removed through a large pipe which is connected to the chamber in a manner such that, if the vacuum is broken suddenly, the inrushing air will not greatly disturb the bed of material being dried. This line leads to a condenser where moisture or solvent that has been vaporized is condensed. The noncondensable exhaust gas goes to the vacuum source, which may be a wet or diy vacuum pump or a steam-jet ejector. [Pg.1192]

In rooms where air and contaminant movement is dominated by thernnal energy of heat sources (e.g., in rooms with natural or displacement ventilation), temperature and contaminant stratification along the room height is created. Air supply and exhaust in such rooms are designed not to disturb the natural pattern of air movement created by heat sources cooled air enters the room in... [Pg.436]

In the stratification strategy the supply air is used to substitute the outgoing air from the ventilated (in most cases occupied) zone, thus preventing circulation patterns between the zones. The supply air has to be distributed in such a way that the buoyancy flows are not disturbed. Exhaust air openings are to be located downstream in order to avoid reverse currents within the room. The location of the contaminant sources and the heat sources causing density differences must be the same in order to carry out the contaminants with equal or higher density than air. [Pg.634]

The demands and design of a local ventilation system (not only local ex hausts) should naturally start with the demanded target levels and the toxicity of the air contaminants (see Chapters 5 and 6). For best performance the exhaust should be close to the source and preferably enclose the source, there should be no disturbances of the flow, and at the same time it should have a low flow rate and be able to minimize the concentration of even quite dangerous air contaminants in the working zone. [Pg.810]

The supply airflow rate should approximately equal the exhaust flow rate. A minor difference between supply and exhaust flow rates should nor disturb the exhaust, since exhaust systems usually are operated with higher pressure differences than supply systems. If the exhaust flow rate is higher than the supply, it could result in lower efficiency due to lower exhaust flow rates and cross-drafts (see Disturbances). If the exhaust flow rate is lower than the supply flow rate, there may be fewer problems with exhaust efficiency, but this could result in a supply airflow field different from the designed one and thus result in different kinds of disturbances. [Pg.824]

Use of warm processes on a downdraft table should be avoided since the air velocity created by the exhaust is often lower than the velocity due to buoyancy effects. Effective use of a downdraft table for welding requires velocities high enough to counteract the buoyancy, which could result in disturbances of the welding process. [Pg.876]

Also, when using cold processes on a downdraft table, the worker should avoid leaning over the working place or sitting too close to it, since this could disturb the flow into the exhaust and increase the spread of contaminants into the workspace. The same effects as when using fume cupboards could easily be the result (Section 10.2.3.3). [Pg.876]

Equipment and supplies should be placed in the enclosure before a contaminant-generating procedure commences. Unnecessary equipment should be removed. High-input heat sources within an enclosure will cause convection currents that can disturb the flow and should be avoided, if possible, or accounted for with correct placement of baffles and/or exhaust connections. [Pg.880]

Sometimes it is necessary to include the exhaust air when designing an air jet system (see Sections 10.4.2 and 10.4.3). Normally the descriptions assume that the jet is not disturbed by exhaust air, nearby surfaces, or other air movement in the room (see Chapter 7). [Pg.919]

Exterior hoods intended to capture contaminants should be placed as close to contaminant sources as possible. In actual practice, however, the hoods can not always be placed close to the source due to circumstances such as working conditions. In such cases, to enhance the exhaust efficiency of exterior hoods, it is useful to use a low-momentum air supply directed toward the exhaust outlet. The supply airflow, which functions to transport contaminants emitted from sources located at a distance from the exhaust outlet,. should be relatively low with a uniform velocity but high enough so that it is not disturbed by the. surrounding air motions. The advantages of using low-momentum supply with exterior hoods are that (1) a lower supply airflow rate to the workspace is possible, (2) a lower exterior hood exhaust flow rate is possible, and (3) it is possible to supply clean air to the breathing zone of the worker. [Pg.966]

The technique provides a very exhaustive analysis of errors in both normal and disturbed conditions. [Pg.196]

While the pzc of Hg in F solution has not changed by more than 1 mV for over 70 years, marginal variations are visible for Ga, Tl, In, Cd, Bi, Sn, and Sb that are related to electrolyte effects (weak specific adsorption or disturbance of the adsorbed water layer, as for Ga).847 Important variations can be seen, on the other hand, for polycrystalline Ag, Zn, Ni, Fe, and Cu. For all these metals a drop of the pzc to much more negative values has been recorded this is evidently related to an improvement in the preparation of the surface with more effective elimination of surface oxides. All these metals, with the exception of Ag, are naturally sensitive to atmospheric oxygen. Values of pzc for single-crystal faces first appeared in a 1974 compilation,23 in particular for the three main faces of Ag and for Au (110). Values for a number of other metals were reported in 1986.25 However, for sd-metals, an exhaustive, specific compilation of available experimental data was given by Hamelin etal. in 1983.24... [Pg.152]

Heat stroke is the state in which heat stress induces a dangerously high core temperature that leads to tissue damage and particularly cerebral disturbance. The core temperature usually exceeds 40°C. The condition may follow heat exhaustion but the temperature rise may occur before salt or water depletion have had time to become manifest. Many organ systems may be affected by acute heat stroke including the brain, kidney, liver and muscles. Disturbance of the hypothalamic heat regulatory centre can lead to a loss of physiological responses to the... [Pg.516]

A 33-year-old woman has recently undergone a divorce. She reports that although she is exhausted, it usually takes her 2 or more hours to fall asleep at night. Which of the following drugs would help relieve her sleep disturbance while being least disruptive to REM sleep ... [Pg.362]

Patients suffering from stress, insomnia, emotional disturbance and exhaustion... [Pg.20]

At certain times, patients may experience extreme stress, anxiety, insomnia, tiredness and exhaustion, and at these times the body becomes very sensitive because the balance of Yin and Yang, and the normal relationship between the internal organs, are disturbed. In treatment, it is important to take into account all the relevant factors, such as how the Qi and the blood tend to move, the sensitivity of the body and the mind, and the possible coexistence of heat and cold, as well as weakness and excess. Herbal formulas should be gentle and balanced, and their administration should be carefully considered, as any strong reaction to the treatment may cause more disturbance to the patient s condition. [Pg.20]


See other pages where Exhaustion disturbance is mentioned: [Pg.95]    [Pg.44]    [Pg.631]    [Pg.815]    [Pg.820]    [Pg.822]    [Pg.824]    [Pg.826]    [Pg.844]    [Pg.849]    [Pg.960]    [Pg.975]    [Pg.997]    [Pg.1121]    [Pg.375]    [Pg.229]    [Pg.339]    [Pg.95]    [Pg.133]    [Pg.71]    [Pg.38]    [Pg.108]    [Pg.286]    [Pg.168]    [Pg.15]    [Pg.36]    [Pg.600]    [Pg.75]    [Pg.51]    [Pg.117]    [Pg.279]    [Pg.95]    [Pg.524]    [Pg.735]   