Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Enantiomer recognition chromatography

Enantiomer Recognition in Normal-Phase Liquid Chromatography... [Pg.187]

The method has been applied to study the enantiomer recognition of the protein monoamine oxidase (MAO), which has been used for affinity liquid chromatography. A mutant preparation method has been described using D-amino acid oxidase (DAO). The optimized structure of the docked complex between a protein and a substrate is obtained by performing molecular mechanics calculations, and the data indicates the degree of complex tightness. [Pg.250]

In another study, the authors reported a comparative study of the enantiomeric resolution of miconazole and the other two chiral drugs by high performance liquid chromatography on various cellulose chiral columns in the normal phase mode [79], The chiral resolution of the three drugs on the columns containing different cellulose derivatives namely Chiralcel OD, OJ, OB, OK, OC, and OE in normal phase mode was described. The mobile phase used was hexane-isopropanol-diethylamine (425 74 1). The flow rates of the mobile phase used were 0.5, 1, and 1.5 mL/min. The values of the separation factor (a) of the resolved enantiomers of econazole, miconazole, and sulconazole on chiral phases were ranged from 1.07 to 2.5 while the values of resolution factors (Rs) varied from 0.17 to 3.9. The chiral recognition mechanisms between the analytes and the chiral selectors are discussed. [Pg.52]

Affinity liquid chromatography and chiral separations (enantiomer separations) require similar analyte properties. The solutes may have interactions through hydrogen-bonding, ligand formation, or Coulombic forces with the surface of stationary phase materials or the sites of additives however, the selectivity is controlled by the steric effects of the structures of the analyte molecules and the recognition molecules (chiral selectors). [Pg.9]

In principle, mass spectrometry is not suitable to differentiate enantiomers. However, mass spectrometry is able to distinguish between diastereomers and has been applied to stereochemical problems in different areas of chemistry. In the field of chiral cluster chemistry, mass spectrometry, sometimes in combination with chiral chromatography, has been extensively applied to studies of proton- and metal-bound clusters, self-recognition processes, cyclodextrin and crown ethers inclusion complexes, carbohydrate complexes, and others. Several excellent reviews on this topic are nowadays available. A survey of the most relevant examples will be given in this section. Most of the studies was based on ion abundance analysis, often coupled with MIKE and CID ion fragmentation on MS " and FT-ICR mass spectrometric instruments, using Cl, MALDI, FAB, and ESI, and atmospheric pressure ionization (API) methods. [Pg.196]

Figure 26-33 Separation of enantiomers of eight p blocker drugs by micellar electrokinetic chromatography at pH 8.0 in a 120-cm capillary at 30 kV. Micelles were formed by a polymer surfactant containing L-leucinate substituents for chiral recognition. The structure of one compound is shown. [From C. Akbay. S, A. A. Rizvi. and S. A. Shamsi, "Simultaneous Enantiosepcration and Tandem UV-MS Detection of Eight p-Blockers in Micellar Electrokinetic Chromatography Using a Chiral Molecular Micelle Anal. Chem. 2005, 77.1672.]... Figure 26-33 Separation of enantiomers of eight p blocker drugs by micellar electrokinetic chromatography at pH 8.0 in a 120-cm capillary at 30 kV. Micelles were formed by a polymer surfactant containing L-leucinate substituents for chiral recognition. The structure of one compound is shown. [From C. Akbay. S, A. A. Rizvi. and S. A. Shamsi, "Simultaneous Enantiosepcration and Tandem UV-MS Detection of Eight p-Blockers in Micellar Electrokinetic Chromatography Using a Chiral Molecular Micelle Anal. Chem. 2005, 77.1672.]...
Since Pasteur separated crystalline sodium ammonium tartrate manually in 1848, many researchers have worked on the subject of enantiomeric separation. In 1939 Henderson and Rule fully separated derivatives of camphor by column chromatography using lactose as a stationary phase material [1]. Gil-Av et al. [2] were able to separate amino acid derivatives on a polysiloxane-based stationary phase by gas chromatography (GC) in 1966. Since then many approaches for a successful distinction between enantiomers have been developed for capillary GC and liquid chromatography [3]. It is still a current topic for researchers searching for chiral separation with SciFinder [4] results in 812 hits and searching for chiral recognition leads to 285 hits for the year 2003 only. [Pg.324]


See other pages where Enantiomer recognition chromatography is mentioned: [Pg.194]    [Pg.443]    [Pg.452]    [Pg.157]    [Pg.68]    [Pg.19]    [Pg.37]    [Pg.62]    [Pg.63]    [Pg.299]    [Pg.62]    [Pg.299]    [Pg.58]    [Pg.76]    [Pg.309]    [Pg.199]    [Pg.239]    [Pg.27]    [Pg.123]    [Pg.48]    [Pg.158]    [Pg.237]    [Pg.397]    [Pg.173]    [Pg.195]    [Pg.197]    [Pg.203]    [Pg.361]    [Pg.362]    [Pg.1267]    [Pg.1037]    [Pg.62]    [Pg.63]    [Pg.86]    [Pg.209]    [Pg.210]    [Pg.224]    [Pg.253]    [Pg.261]   
See also in sourсe #XX -- [ Pg.285 ]




SEARCH



Chromatography, enantiomers

Enantiomer recognition

© 2024 chempedia.info