Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Emergency shut offs

Identifies safeguards such as emergency shut-offs graphically or by detailed description of the location. [Pg.276]

VIII Appendices Useful reference materials such as maps, fire water system diagrams, critical utility emergency shut off points, names and contacts for service providers should be Included. [Pg.365]

Cast iron is undesirable (and prohibited by certain flammable liquid codes) because a brittle fracture can lead to a massive leak. Some months after this mistake, the unit received a loss prevention audit and as a result the pump bowls were replaced with ductile iron units. This same audit prompted the installation of remotely operated emergency shut-off valves around these pumps. [Pg.186]

Burner System. A modified 5.28 GJ/h burner is also on site to combust the low heating value gas. The burner consists of a 15 cm special wide range burner, pressure pilot, flame rod, combustion air blower with motor, micro ratio valve assembly and an emergency shut off valve. The burner size has been increased compared to a normal burner operating with natural gas. The pilot is operated on propane to ensure adequate ignition. [Pg.372]

Emergency Shut-Off Systems for Bulk Transfer of Chlorine 3 1997... [Pg.849]

Two men operated a tree removal service. After cutting down a tree, they removed the branches from the trunk. Then they started feeding tree branches into a chipper pulled behind their dump truck. One man inserted a sizeable branch into the in-feed hopper of the chipper. However, the branch caught the sleeve on his shirt and began pulling him into the hopper. He yelled to his partner. Neither the operator nor his partner could stop the operation quickly because the chipper had no emergency shut-off switches on the hopper. By the time his partner got to the main controls on the engine, the first operator had lost an arm. [Pg.160]

A safety manager was asked to determine if an emergency shut-off switch was located at a height that workers could be expected to reach in the event of an emergency. The... [Pg.38]

Tree cutting First aid kit carried Emergency shut off available working in pairs event rehearsal. [Pg.76]

Are overhead switch box emergency shut-off poles available Yes No N/A... [Pg.218]

The different methods of unloading may require different valve types and related equipment. In all cases, the liquid unloading lines should be equipped with pressure gauges and shut-off valves. As mentioned earlier, the unloading lines should be equipped with properly sized excess flow valves or emergency shut-off valves to protect against loss of product in the event of a hose failure. [Pg.104]

What emergency shut-off systems should you know about for research labs ... [Pg.118]

Was equipnaent provided with emergency shut-off control O YesQ No Was it used O Yes Did it work properly Yes No... [Pg.469]

An emergency shut-off valve is located on the lift truck near the tank to be used in the event of a fuel leak. The valve only requires a quarter turn to shut off the fuel in an emergency. If any worker smells natural gas in or around the engine area, there may be a leak in the CNG system. The quarter-turn valve should be turned to the off position and a trained and authorized mechanic should evaluate the truck. [Pg.308]


See other pages where Emergency shut offs is mentioned: [Pg.125]    [Pg.155]    [Pg.277]    [Pg.278]    [Pg.610]    [Pg.100]    [Pg.274]    [Pg.511]    [Pg.103]    [Pg.277]    [Pg.99]    [Pg.384]    [Pg.90]   