Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Em, measurement

EMS measurements can be described by the theory of isolated molecules. In Figure 7... [Pg.213]

Thus, in addition to the dispersion itself, we get information about which band is occupied in which Brillouin zone. This is a consequence of the fact that EMS measures real momentum, and not, like for example angle-resolved photoemission, crystal momentum. [Pg.216]

Expressible moisture (EM) measures the water that can be squeezed out of a material, generally under a force. Traditionally, the Carver press was used with meats (Forbes et al., 1974 Lee and Patel, 1984). A piece of meat was placed between large pieces of filter paper. The press squeezed out the moisture, and the investigator measured the diameter of the wet circle on the filter paper. One of the problems with the Carver press method is ensuring the use of consistent pressure each time. Also, one can only measure a single sample at a time. Because of the arbitrariness of the conditions, the exact relationship to a real sample is not known. The actual amount of moisture loss is also not determined. [Pg.319]

Rotter JI, Landaw EM. Measuring the genetic contribution of a single locus to a multilocus disease. Clin Genet 1984 26 529-542. [Pg.581]

Electromagnetics (EM). Electromagnetics (EM) measurements provide similar data as obtained using the resistivity method these data are called ground conductivities (or reciprocal resistivities). Some of the newer EM techniques are portable, permitting data to be gathered as fast as a man can walk. Therefore, the EM method has an advantage over the older resistivity method in that subsurface conductivities (reciprocal resistivities) can be collected rapidly and continuously as the operator and instrument move across the land surface. [Pg.105]

A point defect model has been proposed for the brownmillerite structure, based on a study of electrical conductivity and em/measurements of Ba2ln205 [236]. The experimental results matched well with modelling, while evidence was found for protonic conduction at low temperatures. In modelling, the unoccupied oxygen sites relative to the perovskite structure, below Tj, are regarded as structural units and therefore are potential interstitial sites for... [Pg.500]

The EM measured for [Phenjl AcPEI may be compared with that for entero-bactin. The EM of a catechol unit toward a Fe(III) ion bound to another catechol unit contained in enterobactin is estimated at 3 X 10 M. Enterobactin contains three catechol units, whereas the Cu(II) binding site of [Phen2] AcPEI consists of only two phenanthrolines. Nevertheless, the EM value observed for [Phen2] AcPEI is extraordinary for an artificial system. [Pg.271]

From a structural perspective, the degree of interface modification is responsible for regulating the kinetics of the em/measurement as a function of its influence on the structural gas permeability of electrodes, which controls the initial rate of physic-chemical reactions of adsorption-desorption and diffusion on electrodes. In addition, the sensitivity of the zirconia gas sensors is highly sensitive to chemistry and can be lost by minor changes either in the phase purity or at the presence of metallic admixtures in the ceramic ionic conductors. [Pg.30]

Experimental. Samples for electrophoretic mobility (EM) measurements were prepared as previously described for the titration experiments except that violent mixing with destruction of carbon agglomerates was desirable here and was promoted with a 5-10 minute treatment of the capped serum bottles in an ultrasonic bath. The indicator was, of course, deleted in the EM sample preparation procedure. Following mixing, a few drops of the mixture was transferred to a 25 ml flask of benzene and given another ultrasonic treatment. This procedure produced a fairly stable colloid suspension of the carbon black which was used to fill the glass-Teflon commercially available EM cell manufactured by Zeta-Meter, Inc. [Pg.210]

Results. The results of individual EM measurements on groups of colloidal particles of varying size and at different applied fields and field polarities are presented in Figure 7 in the format of a histogram located at the parent mixture mass ratio. The bars appearing in Figure 7 include the total range of 3 to 10 measured EM values for each of one to three colloid samples prepared from each parent mixture. [Pg.212]

The titration experiments, the EM measurements, and the

complementary information about the properties of the carbon black as manifested in their interactions with the white reference solids. It is appropriate to ask what these results taken together say about the surface properties of carbon black. [Pg.218]

In Figure 9 we present the EM of am-Fe(OH)3 in comparison to the EM of am-Fe(OH)3 in the presence of 0.01 and 1.0 mM As(V) all as a function of solution pH. These data were collected using a Zeta-Meter 3.0 system (Zeta Meter, Long Island City, NY mention of trade names is for the benefit of the reader only and does not indicate endorsement by the USDA or USEPA). Suspensions containing 0.2 g L solid in 0.01 M NaCl (with and without As) were acidified with HCl to pH 3.0, equilibrated for 1 h and then titrated with 0.01 M NaCl to various pH values for EM measurements. The PZC was determined by interpolation of the data to zero mobility. [Pg.159]

EM measurements were made using a Zeta-Meter model 3.0 system on suspensions of Fe oxide consisting of 0.2 g of solid and 50 mL of solution. Solutions consisted of 0.01 M NaCl and 0, 0.01, and 1.0 mM arsenite. The EM data presented in Figure 9 show a downward shift in the PZC, but considerably less than observed for As(V) at comparable levels of As sorption. The sorption reaction also caused a net decrease in pH. The amount of OH consumed (H released) relative to As sorbed was 0.103 and 0.021 at pH 5 and 8, respectively. [Pg.165]

Figure 16 Comparison of the values of effective molarity (EM) measured in toluene with the values in 1,1,2,2-tetrachloroethane for intramolecular H-bond formation in Hunter s zinc porphyrin—pyridine complexes. The dashed line corresponds to log EM(TCE) = log EM(toluene). Figure 16 Comparison of the values of effective molarity (EM) measured in toluene with the values in 1,1,2,2-tetrachloroethane for intramolecular H-bond formation in Hunter s zinc porphyrin—pyridine complexes. The dashed line corresponds to log EM(TCE) = log EM(toluene).
Ferrer I, Thurman EM. Measuring the mass of an electron by LC/TOF-MS A study of twin ions . Analy Chem 2005 77 3394-3400. [Pg.442]

For most of these individual potentials, the final expression takes the form of the Nernst equation (Eq. 14). Experimental conditions or circumstances can be such, that Em measures one or a combination of these potentials. Specifically (1) for a symmetrical BLM, the polarization potential, Ep, is unimportant, (2) for an unmodified BLM, whose interior is liquid-hydrocarbon-like, Arf) is not measured, (3) for BLM with low interfacial charge density (e.g. a < 1, net charge per 100 A2), A(pG contributes very little, (4) for charged species with substantial solubihty in BLM, Arp may be neglected, and (5) for a BLM with high interfacial charge density... [Pg.5820]

For the Co radionuclide, the half-life period is 270 days. Its nuclear decay proceeding via electron capture gives the stable Fe isotope and is accompanied by specific physical and chemical aftereffects (various details, consequences, and possible applications of Co radioactive decay aftereffects with regard to Co EMS measurements have been recently discussed, for example, in Refe. 5,6,8,10,11,33-36). The resulting recoil energy (ca. 4.6 eV) for the daughter Fe nucleus is sufficiently low, so that the nucleogenic iron atoms do not shift from their positions, and in many cases their chemical... [Pg.334]

Emission Mossbauer spectra of dried cells of Azospirillum brasilense (strain Sp245) that were incubated as live cells with CoCl2 for 2 min (a) and 60 min (b) at ambient temperature, then rapidly frozen in liquid nitrogen and freeze-dried prior to EMS measurements (spectra measured at 7=80 K see also Table 17.1). The positions of spectral components (quadrupole doublets) composing the whole spectrum (solid envelope), obtained by fitting the experimental data (points), are shown above the spectra with square brackets the same for other figures with emission spectra. (Adapted from Ref. 27.)... [Pg.337]

Cobalt(ll) acts as an activating cation or a cofactor in a variety of enzymes, which could thus be directly probed using Co doping and EMS measurements. Moreover, Co has also been shown to be applicable as an isostructural substitute, for example for Zn + in many zinc-containing proteins [43], and even to enhance enzyme s beneficial properties (see, for example. Refs 48,49 and references therein). [Pg.345]

Co EMS measurements have shown for the first time that this nuclear chemistry technique is sensitive (i) to differences in the coordination of Co" cations at different cation-binding sites within the enzyme active centers and (ii) to differences in the binding affinity of the sites to Co". Further recent studies have also revealed Co EMS sensitivity... [Pg.345]

All these cases should be considered keeping in mind that in EMS measurements, one uses a nucleogenic Fe probe with the coordination environment of the mother nuclide Co preserved. Aftereffects are not considered due to high electron mobility in these perovskites. The nearest neighbor (NN) metal environment of the normal (TMS) and nucleogenic Fe (EMS) is illustrated in Fig. 19.11. [Pg.403]

Before discussing the diffusion of the homopolymer chains into the copolymer structure it is important to discuss the bulk and surface properties of the copolymers. The bulk characterization was accomplished using small-angle X-ray scattering (SAXS). Ideally, electron microscopy (EM) measurements should be done but preliminary studies were unsuccessful because of considerable electron beam damage to the PMMA. The surface characterization was done using X-ray photoelectron spectroscopy (XPS). This technique is more usefull for determining surface compositions than EM. [Pg.333]


See other pages where Em, measurement is mentioned: [Pg.209]    [Pg.212]    [Pg.263]    [Pg.377]    [Pg.684]    [Pg.210]    [Pg.139]    [Pg.153]    [Pg.158]    [Pg.199]    [Pg.212]    [Pg.213]    [Pg.216]    [Pg.219]    [Pg.124]    [Pg.198]    [Pg.201]    [Pg.202]    [Pg.215]    [Pg.137]    [Pg.139]    [Pg.173]    [Pg.336]    [Pg.344]    [Pg.412]    [Pg.36]   
See also in sourсe #XX -- [ Pg.1039 ]

See also in sourсe #XX -- [ Pg.1039 ]

See also in sourсe #XX -- [ Pg.1039 ]




SEARCH



Em, measurement fluorescent probes

Em, measurement microelectrodes

Em, measurement permeant ion distribution

© 2024 chempedia.info