Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Electrothermal atomic absorption examples

In order to overcome the problem of the high nonspecific absorption, alternative procedures have been tested, which involve prior separation of the trace metals from the salt matrix. Examples of extraction of trace metals from seawater as chelates with subsequent determination by electrothermal atomic absorption spectrometric procedures have been described [381,382], but these and similar methods are seldom effective and satisfactory when the matrix is very complex and the analyte concentration very low. [Pg.186]

Thirty-two sherds representing five different examples of Kayenta Anasazi Pueblo II pottery (Tusayan Corrugated [TC], Medicine Black-on-Red [MB], Tusayan Black-on-Red [TB], Dogoszhi Black-on-White [DB], and Sosi Black-on-White [SB]) have been analyzed for the elements As, Ba, Co, Cr, Cm, Fe, Mn, Ni, Pb, Se, V, and Zn by using the techniques of flame atomic absorption spectroscopy (.FAA) and electrothermal atomic absorption spectroscopy (ETAA). Analytical procedures for the chemical analysis of ceramics afford accuracy and sensitivity and require only a modest capital investment for instrumentation. The sherd samples were collected at two sites, one in southern Utah (Navajo Mountain [NM]) and the second in northern Arizona (Klethla Valley [KV]). These sites are approximately 60 km apart. Statistical treatment of the data shows that only three clay types were used in the 32 sherds analyzed, and that only three elements (Fe, Pb, and Ni) are necessary to account for 100% of the dispersion observed within this sample set. [Pg.129]

Extraction systems with following electrothermal atomic absorption spectroscopy (ET-AAS) may be useful in some cases. For example, Zendelovska and Stafilov (2001) used isoamyl acetate extraction with following ET-AAS for thallium analysis in sulfide minerals. Eleischer (1997) reported a detection limit of 0.8 JgL when using ET-AAS with matrix modification (uirmineralized urine, diluted 1 2). [Pg.1100]

Some specific applications are tabulated in Table 2.7, presenting examples of applications of flame atomic absorption spectro-metric analytical techniques to elemental determinations in a variety of materials, while Table 2.8 lists examples of applications of electrothermal atomic absorption spectrometric analytical techniques. [Pg.1563]

Atomic absorption using either flame or electrothermal atomization is widely used for the analysis of trace metals in a variety of sample matrices. Using the atomic absorption analysis for zinc as an example, procedures have been developed for its determination in samples as diverse as water and wastewater, air, blood, urine, muscle... [Pg.415]

The measurement of very low levels of environmental pollutants is becoming increasingly important. The determination of lead, a cumulative toxin, is a good example. The current maximum allowable concentration of lead in British drinking water, before it enters the distribution network, is SO ng ml [29]. Although electrothermal atomization atomic-absorption spectrometry (AAS) can be used to measure this and lower concentrations, it is slow and requires considerable effort to ensure accurate results. Flames can provide simple and effective atom sources, but, if samples are aspirated directly, do not provide sufficient sensitivity. Thus, if a flame is to be used as the atom source, a preconcentration step is required. [Pg.151]

The most suitable techniques for the rapid, accurate determination of the elemental content of foods are based on analytical atomic spectrometry, for example, atomic absorption spectrometry (AAS), atomic emission spectrometry (AES), and mass spectrometry, the most popular modes of which are Game (F), electrothermal atomization (ET), and hydride generation (HG) AAS, inductively coupled plasma (ICP), microwave-induced plasma (MIP), direct current plasma (DCP) AES, and ICP-MS. Challenges in the determination of elements in food include a wide range of concentrations, ranging from ng/g to percent levels, in an almost endless combination of analytes with matrix speci be matrices. [Pg.20]

An example of a calibration curve for Cd with a Zeeman electrothermal atomization atomic absorption spectrometry (ET-AAS) is presented in Figure 6.1. A simple linear regression model is fitted through the data points. The response of the ET-AAS is placed on the ordinate and the concentration of the injected standard solutions on the abscissa. The concentration of the unknown samples can be calculated back as X = (Yt — a)/b. [Pg.137]

Flameless atomic absorption using an electrothermal atomiser is essentially a non-routine technique requiring specialist expertise. It is slower than flame analysis only 10—20 samples can be analysed in an hour furthermore, the precision is poorer (1—10%) than that for conventional flame atomic absorption (1%). The main advantage of the method, however, is its superior sensitivity for any metal the sensitivity is 100—1000 times greater when measured by the flameless as opposed to the flame technique. For this reason flameless atomic absorption is employed in the analysis of water samples where the flame techniques have insufficient sensitivity. An example of this is with the elements barium, beryllium, chromium, cobalt, copper, manganese, nickel and vanadium, all of which are required for public health reasons to be measured in raw and potable waters (section I.B). Because these elements are generally at the lOOjugl-1 level and less in water, their concentration is below the detection limit when determined by flame atomic absorption as a result, an electrothermal atomisation (ETA) technique is often employed for their determination. [Pg.86]

Atomic absorption spectrometry with flame (AA-F) or electrothermal atomization furnace (AA-ETA), inductively coupled plasma-emission spectroscopy (ICP-ES), inductively coupled plasma-mass spectrometry (ICP-MS), and high-performance liquid chromatography-mass spectrometry (LC-MS) are state-of-the-art analytical techniques used to measure metals in biological fluids. They are specific and sensitive and provide the cfinical laboratory with the capability to measure a broad array of metals at clinically significant concentrations. For example, ICP-MS is used to measure several metals simultaneously. Photometric assays are also available but require large volumes of sample and have limited analytical performance. Spot tests are also... [Pg.1373]

I) Analytical technique or method, occasionally unfeasible with the Involvement of an operator —this book abounds In Illustrative examples of this kind. Thus, electrothermal vaporization atomic absorption spectroscopy demands the automation of the sample thermal treatment In the graphite tube via a microprocessor programming the different heating stages involved (automation of methodology). Likewise, the use of Image detectors In spectroscopy calls for computerized data acquisition, impossible with manual operators. [Pg.4]


See other pages where Electrothermal atomic absorption examples is mentioned: [Pg.250]    [Pg.250]    [Pg.361]    [Pg.50]    [Pg.196]    [Pg.812]    [Pg.1535]    [Pg.380]    [Pg.1066]    [Pg.68]    [Pg.168]    [Pg.259]    [Pg.241]    [Pg.1628]    [Pg.122]    [Pg.411]    [Pg.646]    [Pg.432]    [Pg.436]    [Pg.296]    [Pg.1544]    [Pg.141]    [Pg.145]    [Pg.34]   
See also in sourсe #XX -- [ Pg.207 , Pg.212 , Pg.213 , Pg.217 , Pg.218 , Pg.222 , Pg.225 , Pg.226 , Pg.331 , Pg.332 ]




SEARCH



Atomic electrothermal

Electrothermal

Electrothermal atomic absorption

Electrothermal atomization absorption

Electrothermal atomization atomic absorption

Electrothermal atomizers

Electrothermics

© 2024 chempedia.info