Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Electrical low pressure impactors

The electrical low-pressure impactor was used to measure the number concentrations of diesel exhaust particles. The particle size distribution ranges from 30 nm upward were then determined using the aerodynamic diameter as the characteristic dimension. ... [Pg.1294]

Note DMS differential mobility spectrometer, SMPS scanning mobility particle sizer, CPC condensation particle counter, TDMPS twin differential mobility particle sizer, DMPS differential mobility particle sizer, OPC optical particle counter, APS aerodynamic particle sizer, MAS mass aerosol spectrometer, LAS-X optical laser aerosol spectrometer, ELPI electrical low pressure impactor... [Pg.352]

Van Gulijk, C., Marijnissen, J.C.M., Makkee, M., Moulijn, J.A. and Schmidt-Ott, A. (2004). Measuring diesel soot with a scanning mobility particle sizer and an electrical low-pressure impactor performance assessment with a model for liactal-fike agglomerates. J. Aerosol ScL, 35, 633-655. [Pg.311]

The electrical Itw-pressure impactor (ELPl) has been developed, using the Berner-type multijet low-pressure impactor stages. The cut sizes of the seven channel system range from 0.030 to 1.0 pm. Real-time measurements can be achieved due to the instrument s fast time response. The schematic representation of the impactor construction is shown in Fig 13.44. [Pg.1294]

Kwok, P.C.L. Chan, H.-K. Measurement of electrostatic charge of nebulised aqueous droplets with the electrical 79. low pressure impactor. In Respiratory Drug Delivery IX ... [Pg.1547]

The size distribution of the particulate matter in the 0.01-5 ym size range is analyzed on line using an electrical mobility analyzer and an optical particle counter. Samples of particles having aerodynamic diameters between 0.05 and 4 ym are classified according to size using the Caltech low pressure cascade impactor. A number of analytical procedures have been used to determine the composition distribution in these particles. A discrete mode of particles is observed between 0.03 and 0.1 ym. The major components of these particles are volatile elements and soot. The composition of the fine particles varies substantially with combustor operating conditions. [Pg.157]


See other pages where Electrical low pressure impactors is mentioned: [Pg.1294]    [Pg.1295]    [Pg.425]    [Pg.466]    [Pg.1541]    [Pg.610]    [Pg.283]    [Pg.308]    [Pg.265]    [Pg.266]    [Pg.1294]    [Pg.1295]    [Pg.425]    [Pg.466]    [Pg.1541]    [Pg.610]    [Pg.283]    [Pg.308]    [Pg.265]    [Pg.266]    [Pg.295]    [Pg.205]    [Pg.44]    [Pg.93]    [Pg.168]   
See also in sourсe #XX -- [ Pg.264 ]




SEARCH



Electric pressure

Impactors

Low pressure

Low-pressure impactor