Glass-transition temperatures are commonly determined by differential scanning calorimetry or dynamic mechanical analysis. Many reported values have been measured by dilatometric methods however, methods based on the torsional pendulum, strain gauge, and refractivity also give results which are ia good agreement. Vicat temperature and britde poiat yield only approximate transition temperature values but are useful because of the simplicity of measurement. The reported T values for a large number of polymers may be found ia References 5, 6, 12, and 13. [Pg.260]

Thermal Properties. Spider dragline silk was thermally stable to about 230°C based on thermal gravimetric analysis (tga) (33). Two thermal transitions were observed by dynamic mechanical analysis (dma), one at —75° C, presumed to represent localized mobiUty in the noncrystalline regions of the silk fiber, and the other at 210°C, indicative of a partial melt or a glass transition. Data from thermal studies on B. mori silkworm cocoon silk indicate a glass-transition temperature, T, of 175°C and stability to around 250°C (37). The T for wild silkworm cocoon silks were slightly higher, from 160 to 210°C. [Pg.78]

The dynamic mechanical properties of VDC—VC copolymers have been studied in detail. The incorporation of VC units in the polymer results in a drop in dynamic modulus because of the reduction in crystallinity. However, the glass-transition temperature is raised therefore, the softening effect observed at room temperature is accompanied by increased brittleness at lower temperatures. These copolymers are normally plasticized in order to avoid this. Small amounts of plasticizer (2—10 wt %) depress T significantly without loss of strength at room temperature. At higher levels of VC, the T of the copolymer is above room temperature and the modulus rises again. A minimum in modulus or maximum in softness is usually observed in copolymers in which T is above room temperature. A thermomechanical analysis of VDC—AN (acrylonitrile) and VDC—MMA (methyl methacrylate) copolymer systems shows a minimum in softening point at 79.4 and 68.1 mol % VDC, respectively (86). [Pg.434]

The thermal glass-transition temperatures of poly(vinyl acetal)s can be determined by dynamic mechanical analysis, differential scanning calorimetry, and nmr techniques (31). The thermal glass-transition temperature of poly(vinyl acetal) resins prepared from aliphatic aldehydes can be estimated from empirical relationships such as equation 1 where OH and OAc are the weight percent of vinyl alcohol and vinyl acetate units and C is the number of carbons in the chain derived from the aldehyde. The symbols with subscripts are the corresponding values for a standard (s) resin with known parameters (32). The formula accurately predicts that resin T increases as vinyl alcohol content increases, and decreases as vinyl acetate content and aldehyde carbon chain length increases. [Pg.450]

Glass transition temperature (Tg), measured by means of dynamic mechanical analysis (DMA) of E-plastomers has been measured in binary blends of iPP and E-plastomer. These studies indicate some depression in the Tg in the binary, but incompatible, blends compared to the Tg of the corresponding neat E-plastomer. This is attributed to thermally induced internal stress resulting from differential volume contraction of the two phases during cooling from the melt. The temperature dependence of the specific volume of the blend components was determined by PVT measurement of temperatures between 30°C and 270°C and extrapolated to the elastomer Tg at —50°C. [Pg.175]

ASTM E 1640-99, ASTM Book of Standards 2002. Standard Test Method for Assignment of the Glass Transition Temperature by Dynamic Mechanical Analysis . ASTM International, Conshohocken, PA. [Pg.90]

Dynamic Mechanical and Thermomechanical Analysis. A DuPont Model 981 DMA was used to determine the dynamic modulus and damping characteristics of baseline and irradiated specimens. Transverse composite samples 1.27 cm x 2.5 cm were used so that the modulus and damping data were primarily sensitive to matrix effects. Data were generally determined from -120°C through the glass transition temperature (Tg) of each material using a heating rate of 5°C/min. [Pg.227]

Electron irradiation causes chain scission and crosslinking in polymers. Both of these phenomena directly affect the glass transition temperature (Tg) of the materials. Thermomechanical (TMA) and dynamic-mechanical analysis (DMA) provide information about the Tg region and its changes due to radiation damage. Therefore, DMA and TMA were performed on all irradiated materials. [Pg.228]

Fig. 5 4. Glass transition temperature, Tg, measured by dynamic mechanical analysis as a function of wt% epoxy-compatible PPG size. After Drown et al. (1991). Fig. 5 4. Glass transition temperature, Tg, measured by dynamic mechanical analysis as a function of wt% epoxy-compatible PPG size. After Drown et al. (1991).
The dynamic mechanical thermal analysis also indicated molecular mixing of the two components. The Tg of the thermoplastic was lower than the composite, as determined from the inflection point of the E curve seen in Figures 13 1. The PEOX glass transition temperature appeared at 62°C, while that for PVP showed up at ll5°C. The discrepancy in the Tg of PVP had already been addressed. The Tg extrapolated from the DMTA thermogram was reported since no artifacts were to be introduced. The samples exemplified for all DMTA thermograms were processed in a normalized fashion. Any thermal or hygroscopic Influences were eliminated. Some water may be trapped in the neat thermoplastics but this was minimized since they are hot pressed at 150°C and stored under calcium... [Pg.259]

The measurements of Young s modulus in dependence of the temperature (dynamic-mechanical measurements, see Sect. 2.3.5.2) and the differential thermal analysis (DTA or DSC) are the most frequently used methods for determination of the glass transition temperature. In Table 2.10 are listed and values for several amorphous and crystalline polymers. [Pg.120]

The glass transition temperature can be measured in a variety of ways (DSC, dynamic mechanical analysis, thermal mechanical analysis), not all of which yield the same value [3,8,9,24,29], This results from the kinetic, rather than thermodynamic, nature of the transition [40,41], Tg depends on the heating rate of the experiment and the thermal history of the specimen [3,8,9], Also, any molecular parameter affecting chain mobility effects the T% [3,8], Table 16.2 provides a summary of molecular parameters that influence the T. From the point of view of DSC measurements, an increase in heat capacity occurs at Tg due to the onset of these additional molecular motions, which shows up as an endothermic response with a shift in the baseline [9,24]. [Pg.123]

Mijovic et al. analyzed the annealed blends from melts using dynamic mechanical thermal analysis and achieved similar results after an adjustment for shifting factors, AT s, as shown in Figure 7.3. The results were extended to include blends having a PVDF concentration greater than 80 wt %. It can be observed that the glass transition temperatures of the annealed blends reduce rapidly when the PVDF concentrations are above 80 wt %. [Pg.124]

T A a — glass transition temperature determined using dynamic mechanical analysis, K... [Pg.290]

Summary In this chapter, a discussion of the viscoelastic properties of selected polymeric materials is performed. The basic concepts of viscoelasticity, dealing with the fact that polymers above glass-transition temperature exhibit high entropic elasticity, are described at beginner level. The analysis of stress-strain for some polymeric materials is shortly described. Dielectric and dynamic mechanical behavior of aliphatic, cyclic saturated and aromatic substituted poly(methacrylate)s is well explained. An interesting approach of the relaxational processes is presented under the experience of the authors in these polymeric systems. The viscoelastic behavior of poly(itaconate)s with mono- and disubstitutions and the effect of the substituents and the functional groups is extensively discussed. The behavior of viscoelastic behavior of different poly(thiocarbonate)s is also analyzed. [Pg.43]


See other pages where Dynamic mechanical analysis glass transition temperature is mentioned: [Pg.59]    [Pg.49]    [Pg.131]    [Pg.151]    [Pg.151]    [Pg.138]    [Pg.298]    [Pg.410]    [Pg.60]    [Pg.63]    [Pg.792]    [Pg.889]    [Pg.601]    [Pg.115]    [Pg.276]    [Pg.115]    [Pg.36]    [Pg.29]    [Pg.87]    [Pg.419]    [Pg.468]    [Pg.38]    [Pg.76]    [Pg.151]    [Pg.151]    [Pg.265]    [Pg.175]    [Pg.184]    [Pg.74]    [Pg.244]    [Pg.111]    [Pg.296]    [Pg.718]   
See also in sourсe #XX -- [ Pg.540 , Pg.541 ]




SEARCH



Analysis temperature

Dynamic analysis

Dynamic mechanical analysis transition temperatures

Dynamic mechanisms

Dynamic transitions

Dynamical mechanical

Dynamics glass transition

Glass dynamics

Glass transition temperature analysis

Glasses mechanisms

Mechanical analysis

Temperature, dynamics

© 2024 chempedia.info