Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Divider Analysis

To illustrate the basic operation of the Monte Carlo and Worst Case analyses, we will simulate a voltage divider. Create a voltage divider using 5% resistors with Gaussian distributions as follows. [Pg.505]


Analysis. We can divide analysis algorithms into time and frequency domain processes. Certainly, the division between these categories is arbitrary since we can mix them together to solve an audio problem. However, it suffices for our purposes. [Pg.403]

An automated method of analysis for germanium spectra was eventually adopted with the advent of sufficient computing power in an ubiquitous platform. This method was improved until it eventually eliminated all but periodic human QA checks. This automated method (Gunnink and Niday, 1972) divides analysis into five tasks ... [Pg.323]

Modern methods of amino-acid and peptide analysis, have enabled the complete amino-acid sequence of a number of proteins to be worked out. The grosser structure can be determined by X-ray diffraction procedures. Proteins have molecular weights ranging from about 6 000 000 to 5 000 (although the dividing line between a protein and a peptide is ill defined). Edible proteins can be produced from petroleum and nutrients under fermentation. [Pg.332]

Below are brief descriptions of some of the particle-surface interactions important in surface science. The descriptions are intended to provide a basic understanding of how surfaces are probed, as most of the infonuation that we have about surfaces was obtained tluough the use of techniques that are based on such interactions. The section is divided into some general categories, and the important physics of the interactions used for analysis are emphasized. All of these teclmiques are described in greater detail in subsequent sections of the encyclopaedia. Also, note that there are many more teclmiques than just those discussed here. These particular teclmiques were chosen not to be comprehensive, but instead to illustrate the kind of infonuation that can be obtained from surfaces and interfaces. [Pg.305]

In this section, we apply the phase-change rule and the loop method to some representative photochemical systems. The discussion is illustiative, no comprehensive coverage is intended. It is hoped that the examples are sufficient to help others in applying the method to other systems. This section is divided into two parts in the first, loops are constructed and a qualitative discussion of the photochemical consequences is presented. In the second, the method is used for an in-depth, quantitative analysis of one system—photolysis of 1,4-cyclohexadiene. [Pg.366]

How can we apply molecular dynamics simulations practically. This section gives a brief outline of a typical MD scenario. Imagine that you are interested in the response of a protein to changes in the amino add sequence, i.e., to point mutations. In this case, it is appropriate to divide the analysis into a static and a dynamic part. What we need first is a reference system, because it is advisable to base the interpretation of the calculated data on changes compared with other simulations. By taking this relative point of view, one hopes that possible errors introduced due to the assumptions and simplifications within the potential energy function may cancel out. All kinds of simulations, analyses, etc., should always be carried out for the reference and the model systems, applying the same simulation protocols. [Pg.369]

A major potential drawback with cluster analysis and dissimilarity-based methods f selecting diverse compounds is that there is no easy way to quantify how completel one has filled the available chemical space or to identify whether there are any hole This is a key advantage of the partition-based approaches (also known, as cell-bas( methods). A number of axes are defined, each corresponding to a descriptor or son combination of descriptors. Each axis is divided into a number of bins. If there are axes and each is divided into b bins then the number of cells in the multidimension space so created is ... [Pg.701]

Discriminant emalysis is a supervised learning technique which uses classified dependent data. Here, the dependent data (y values) are not on a continuous scale but are divided into distinct classes. There are often just two classes (e.g. active/inactive soluble/not soluble yes/no), but more than two is also possible (e.g. high/medium/low 1/2/3/4). The simplest situation involves two variables and two classes, and the aim is to find a straight line that best separates the data into its classes (Figure 12.37). With more than two variables, the line becomes a hyperplane in the multidimensional variable space. Discriminant analysis is characterised by a discriminant function, which in the particular case of hnear discriminant analysis (the most popular variant) is written as a linear combination of the independent variables ... [Pg.719]

This chapter is divided into two parts The first and major portion is devoted to carbohydrate structure You will see how the principles of stereochemistry and confer matronal analysis combine to aid our understanding of this complex subject The remain der of the chapter describes chemical reactions of carbohydrates Most of these reactions are simply extensions of what you have already learned concerning alcohols aldehydes ketones and acetals... [Pg.1026]

Precision is a measure of the spread of data about a central value and may be expressed as the range, the standard deviation, or the variance. Precision is commonly divided into two categories repeatability and reproducibility. Repeatability is the precision obtained when all measurements are made by the same analyst during a single period of laboratory work, using the same solutions and equipment. Reproducibility, on the other hand, is the precision obtained under any other set of conditions, including that between analysts, or between laboratory sessions for a single analyst. Since reproducibility includes additional sources of variability, the reproducibility of an analysis can be no better than its repeatability. [Pg.62]

Significance testing for comparing two mean values is divided into two categories depending on the source of the data. Data are said to be unpaired when each mean is derived from the analysis of several samples drawn from the same source. Paired data are encountered when analyzing a series of samples drawn from different sources. [Pg.88]

The following experiments may he used to illustrate the application of kinetic methods of analysis. Experiments are divided into two groups those based on chemical kinetics and those using flow injection analysis. Each suggested experiment includes a brief description. [Pg.659]

Colorants. According to U.S. regulations, colorants are divided into two classes certified and exempt (see Colorants for foods, drugs, COSMETICS, AND MEDICAL DEVICES). Batch samples of certified colors must be sent to the FDA for analysis and confirmation that the colorants comply with estabhshed specifications. Color manufacturers pay a small fee for each batch of color that is analy2ed. The number of certified colors available to food technologists has declined. Several of the historical colorants were found to have carcinogenic effects. Table 1 shows the certified colors that are permissible for food use in the United States as of 1993. [Pg.437]

Forensic science laboratories are generally divided into separate specialty areas. These typically include forensic toxicology, soHd-dose dmg testing, forensic serology, trace evidence analysis, firearms and tool mark examination, questioned documents examination, and latent fingerprint examination. Laboratories principally employ chemists, biochemists, and biologists at various degree levels. In some specialty areas, eg, firearms examination, questioned... [Pg.485]

However, for the past 30 years fractional separation has been the basis for most asphalt composition analysis (Fig. 10). The separation methods that have been used divide asphalt into operationally defined fractions. Four types of asphalt separation procedures are now in use ( /) chemical precipitation in which / -pentane separation of asphaltenes is foUowed by chemical precipitation of other fractions with sulfuric acid of increasing concentration (ASTM D2006) (2) solvent fractionation separation of an "asphaltene" fraction by the use of 1-butanol foUowed by dissolution of the 1-butanol solubles in... [Pg.366]

Einely divided samples may be identified further by analyses of the graphite ash, and identification of the minerals associated with the graphite and comparison with graphites from known sources. Owing to its softness and opaqueness, most of the graphitic carbon must be removed from the sample before analysis by either method. There are two general ways of accomplishing this. [Pg.574]


See other pages where Divider Analysis is mentioned: [Pg.505]    [Pg.505]    [Pg.368]    [Pg.1032]    [Pg.2101]    [Pg.474]    [Pg.682]    [Pg.715]    [Pg.1032]    [Pg.180]    [Pg.524]    [Pg.524]    [Pg.625]    [Pg.278]    [Pg.41]    [Pg.78]    [Pg.168]    [Pg.2]    [Pg.191]    [Pg.16]    [Pg.342]    [Pg.42]    [Pg.156]    [Pg.393]    [Pg.515]    [Pg.306]    [Pg.105]    [Pg.393]    [Pg.393]    [Pg.426]    [Pg.195]    [Pg.153]    [Pg.37]    [Pg.103]   


SEARCH



Divide

Divider

© 2024 chempedia.info