Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Direct performance parameters

Defined maintenance procedures should include model or manufacturer specifics and a list of parts to be inspected, cleaned, lubricated, replaced, and/or calibrated. The replacement part numbers, cleaning solutions and lubricants, and calibration standards, along with the manufacturer s maintenance procedures to be followed, should be specified. Documentation is easily managed by creating a one-page checklist of instructions or performance parameters that can be checked off as each task is completed. Any issues or comments can be captured directly on the checklist. Provisions for failure or out-of-tolerance notification need to be clearly defined, as the equipment cannot be put back into service until the performance has been verified by conducting a performance qualification. [Pg.1042]

Carbonaceous materials play a key role in achieving the necessary performance parameters of electrochemical capacitors (EC). In fact, various forms of carbon constitute more than 95% of electrode composition [1], Double layer capacity and energy storage capacity of the capacitor is directly proportional to the accessible electrode surface, which is defined as surface that is wetted with electrolyte and participating in the electrochemical process. [Pg.44]

Monochrome AMPLED flat-panel displays have been made with performance parameters attractive for battery-powered portable applications. The AM backpanel was made of polysilicon material with integrated column and row drivers. Table 1.1 shows a data sheet for a 4" diagonal monochrome display with 960 x 240 pixels [173]. The resolution in horizontal direction was 300 ppi (85pm pitch size), while the resultion in vertical direction was 100 ppi (255 pm pitch size). With 100% pixels turned on at 200 cd/m2, the entire AMPLED panel (including pixel drivers) only consumed eletric power less than 500 mW (with 100% pixels on), which was... [Pg.29]

This is a valid empirical criterion, since sensitivity and hence precision decreases as the curve flattens. However, linearity does not directly measure the performance parameter of interest precision. In practice an analyst would accept curves at high concentrations, providing the precision is still adequate and providing the method does not have accuracy problems at high concentrations e.g., because of light scattering in absorption methods. [Pg.129]

Success in the battery market depends largely on four factors, noted in Figure 10. The market for batteries in Table 1 is directly related to the applications they serve, such as automobiles, cellular phones, notebook computers, and other portable electronic devices. The growth in any particular segment follows closely the introduction of new devices powered by batteries. The introduction of new materials with higher performance parameters gives the various designers freedom to incorporate new functionality in present products or to create new products to... [Pg.13]

Stability and Performance of Bound En me. The stability of the IME was determined by two methods. One measurement of bound activity was obtained using traditional cellulose hydrolysis experiments (described below). In the other method, direct kinetic parameter measurements were obtained using a recirculating differential (RDR) reactor system following the method of Ford et al. (46). [Pg.142]

Autologous (self) skin is harvested from a healthy area of the patient s body and transferred to the wound, generally a burn. The procedure leaves a second injury or donor site. The advantages of non-allergenicity, non-toxicity, non-pyrogenicity, and direct incorporation into the healed area with the overall performance parameters of intact skin make this the dressing of choice. [Pg.1035]

When an analytical procedure is so defined, uncertainty becomes the performance parameter that needs overriding consideration over and above all the others assessed during validation studies. This kind of validation gives a direct answer to the question whether the data produced are of required quality and thus appropriate for their intended use. [Pg.152]

Prototype Efficiency Measurements. A variety of LSC devices have been tested by ourselves and others. Table I is Intended to be a representative list of typical performance parameters. Again, the geometric gain is the ratio of the area exposed to the sun to the active area of the edge. The flux gain is the factor by which the short circuit current increased when attached to the plate, as opposed to facing the sun directly. The cell efficiency is the measured or assumed AMI efficiency of the solar cells used (which in all cased were silicon). The collector efficiency is the total electrical power out divided by the total sunlight power incident on the plate. [Pg.346]

Physical motion is common to most situations in which the human functions and is therefore fundamental to the analysis of performance. Parameters such as segment position, orientation, velocity, and acceleration are derived using kinematic or dynamic analysis or both. This approach is equally appropriate for operations on a single joint system or linked multibody systems, such as is typically required for human analysis. Depending on the desired output, foreword (direct) or inverse analysis may be employed to obtain the parameters of interest. For example, inverse dynamic analysis can provide joint torque, given motion and force data while foreword (direct) dynamic analysis uses joint torque to derive motion. Especially for three-dimensional analyses of multijoint systems, the methods are quite complex and are presently a focal point for computer implementation [Allard et al., 1994]. [Pg.1386]

In the case of compressors, the fundamental performance parameter is pressure ratio, which has a direct relationship to the head. A compressor of any type tends to be rated to achieve a certain pressure ratio for a given flowrate. A restriction in the suction system is more detrimental to performance than a restriction in the discharge. If a compressor is rated to compress a gas from 1 bar absolute to 10 bar absolute, it will be able to maintain a pressure ratio of 10 under varying suction pressure. The temperature ratio (often the limiting machine characteristic) corresponds to the pressure ratio. Thus a pressure loss of 0.2 bar in the suction line will result in a pressure of only (1.0 - 0.2) X 10 = 8 bar in the discharge for the same flow, or for the same temperature rise per stage. [Pg.171]


See other pages where Direct performance parameters is mentioned: [Pg.363]    [Pg.638]    [Pg.16]    [Pg.48]    [Pg.76]    [Pg.90]    [Pg.219]    [Pg.126]    [Pg.114]    [Pg.232]    [Pg.239]    [Pg.152]    [Pg.289]    [Pg.16]    [Pg.99]    [Pg.238]    [Pg.918]    [Pg.452]    [Pg.99]    [Pg.406]    [Pg.34]    [Pg.83]    [Pg.76]    [Pg.616]    [Pg.290]    [Pg.1395]    [Pg.632]    [Pg.65]    [Pg.180]    [Pg.128]    [Pg.381]    [Pg.239]    [Pg.591]    [Pg.619]    [Pg.60]    [Pg.294]   
See also in sourсe #XX -- [ Pg.65 , Pg.66 , Pg.68 ]




SEARCH



Direct performance

Performance parameters

© 2024 chempedia.info