Dew point measurement

Dew point measurements are widely used in scientilic and industrial applications when precise measurement of water vapor pressure is needed. Dew point, the temperature at which water euudensaie heginx to form on a surface, can be accurately measured front -75 C to +101) C across the entire range of humidiiy with a condensation (chilled mirrort hygrometer. [Pg.812]

Three types of instruments have received wide acceptance in dew point measurements tllthe saturated salt dew point sensor 121 the condensation-type hygrometer and t.lt the aluminum oxide sensor. Many other instruments are used in specialized applications, including pressure tatio dev ices, dewcups. and fog chambers. The luttei ate manually operated... [Pg.812]

Dew-point measurement is a primary method based on fundamental thermodynamics principles and as such does not require calibration. However, the instrument performance needs to be verified using salt standards and distilled water before sampling (see Support Protocol). To obtain accurate and reproducible water activity results with a dew-point instrument, temperature, sensor cleanliness, and sample preparation must be considered. Equipment should be used and maintained in accordance with the manufacturer s instruction manual and with good laboratory practice. If there are any concerns, the manufacturer of the instrument should be consulted. Guidelines common to dew-point instruments for proper water activity determinations are described in this protocol. The manufacturer s instructions should be referred to for specifics. [Pg.42]

To obtain accurate and reproducible water activity results with a dew-point instrument, the temperature, sensor cleanliness, and sample preparation must be considered. Temperature influences water activity measurements in two ways one is its effect on the water activity in the sample and the second is the effect on the dew-point measurement. [Pg.47]

BCA protein assay reagent, effect on, 97 water activity, effect on dew-point measurement, 47-48 generally, 47... [Pg.767]

Dew points were also measured using the procedure described above, except that the disappearance of the liquid phase was observed as solvent was added to the view cell. Dew point measurements were limited by low porphyrin concentrations in the gas phase, which required loading very small amounts of porphyrin into the cell. [Pg.140]

Measurements of solid solubilities in supercritical pentane were, in principle, identical to the bubble point or dew point measurements described above. The equilibrium pressure and corresponding solid solubility at a fixed temperature were determined from the measured pressure and known mixture composition in the cell when the last crystal of solid dissolved. These measurements were limited at low solubilities by the low porphyrin loadings, and at high solubilities by the dark purple color of the fluid phase which obscured observation of the solid phase. [Pg.140]

Abe T, Shima H, Watanabe K, Ito Y (2004) Study of PEFCs by AC impedance, current interrupt, and dew point measurements I. Effect of humidity in oxygen gas. J Electrochem Soc 151(l) A101-5... [Pg.137]

Relative humidity in the cave interior approaches the dew point (measured values are invariably higher than 96%) and actual condensation was verified at several sites by the presence of water droplets on data loggers within a period of two months. [Pg.248]

Method (vii) gives the absolute and relative humidity from a dew point measurement. [Pg.1334]

Method (x) allows the dew point to be corrected for pressure. The basis is that the mole fraction y = p/P is the same for a given mixture composition at all values of total pressure P. In particular, the dew point measured in a compressed air duct can be converted to the dew point at atmospheric pressure, from which the humidity can be calculated. It is necessary to check that the temperature change associated with compression or expansion does not bring the dry-bulb temperature to a point where condensation can occur. Also, at these elevated pressures, it is strongly advisable to apply the enhancement factor (see BS 1339). [Pg.1334]

The vapour pressures obtained from dew point measurements will depend on the relationship used for the temperature dependence of the saturated vapour pressure. A number of relationships, = f (7), have been proposed for the equilibrium Se02(cr) Se02(g), see Section V.2.2.3. in Chapter V. In order to obtain consistency it is necessary to revise previous vapour pressures calculated from the dew point temperature, to conform with the accepted = f (7 ) function. The problem met in this revision has been the fact that in some instances only p values have been published, while the dew point temperatures and the relationship used to obtain are absent. [Pg.530]

The temperature of the cylindrical sample surface is measured by means of thermocouples inserted in 0.5 mm diameter holes running parallel with the axis. The inlet and outlet temperatures of the coolant and its flow rate can be measured. A pitot tube located near the test surface measures the local gas velocity. Dew point measurements and particle size analysis, are carried out at the same time as the mass accumulation tests to provide additional relevant data. [Pg.511]

When all the dew points measured in this way are coimected, a steep curve to the right is the result, the so-called boiling pressure curve or vapor pressure curve (Fig. 11.7). It gives the values of pressure and temperature at which gas and... [Pg.303]

In 2007 (O Fig. 20.43c), the gas-flow rate was increased to 1,500 ml/min in order to increase the transport efficiency. The temperature gradient was between +32°C and — 164°C. As a result, the Hg deposition region broadened considerably to 14 detectors. Only about 30% of the Rn deposited on the last four detectors. The faster carrier gas transported three observed atoms of Cn further down to detectors at lower temperatures. Chains 3 and 5 were detected in detectors 11 (—21°C) and 14(—39°C). Chain 4 was detected in detector 26 (—124°C). From dew point measurements in the carrier gas, it has to be concluded that the detector surfaces held below — 95° C were covered by a thin ice layer (O Fig. 20.43a-c, vertical lines). Thus, it was concluded that four events (chains 1-3, and 5) are attributable to atoms of element 112 deposited on the gold surface, while chain 4 represents an atom of element 112 deposited on ice. [Pg.992]

ZnS04. The component determines the speed of deposition of SO2 on the zinc surface from atmospheric measurements of SO2 concentrations (pg/m ). Since the deposition rate depends on the shape of the article, however, is difficult to determine. In polluted environments, may best be estimated according to Spence and Haynie by using the equation RH = 96.03 -0.313DP (where DP is the ambient dew point temperature, C), hence determining the surface wemess of galvanized steel structures from ambient dew point measurements. The last term, 1.29 X lO MrN, represents the cono-... [Pg.150]

Different methods of dew point measurement can be used to determine low moisture contents. For measurements in the parts per million range, the condensation temperature is very low and the precipitated quantities of liquid are small. The actual measurement can be difficult to determine, especially as the condensation points of other components of a gas are approached. Dew points of 0°F to -30°F (-18 C to -34°C) can be... [Pg.65]