Detectors scintillation detector

Scintillation counting Scintillation crystals Scintillation detector Scintillation detectors... [Pg.873]

There are three major classes of X-ray detectors in commercial use gas-filled detectors, scintillation detectors, and semiconductor detectors. Semiconductor detectors will be discussed with EDXRF equipment. Both WDXRF and EDXRF detection makes use of a signal processor called a pulse height analyzer or selector in conjunction with the detector, and discussed subsequently. [Pg.559]

Instruments for measuring ionized radiation typically include a sensing device and a readout device. Some are usefiil for field measurement whereas other combinations come in small packages useful for dosimetry. Sensors are very critical. Different types of radiation require different types of sensors. Sensors include Geiger-MueUer tubes (used in Geiger counters), ionization chambers, luminescent detectors, scintillation detectors, and photographic emulsions. [Pg.313]

The detector efficiency depends on the radiation energy to be determined and the density and type of detector material. In XRF spectrometers three different type of X-ray detectors are used gas-filled detectors, scintillation detectors and semiconductor detectors. [Pg.1298]

The X-ray instrumentation requires a commercial small angle X-ray camera, a standard fine structure X-ray generator and a sample manipulator if scanning is requested. The essential signal is the relative difference between the refraction level Ir and the absorption level Ia. Both levels are measured simultaneously by two scintillation detectors. At fixed angles of deflection this signal depends solely on the inner surface density factor C and thickness d of the sample [2] ... [Pg.558]

Arrival of ions, which have a positive or negative charge, causes an electric current to flow either directly (Faraday cup) or indirectly (electron multiplier and scintillator detectors). [Pg.408]

Detectors. Two general types of detectors are used in x-ray medical imaging scintillation and gas ionisation. Scintillation detectors are used for both conventional projection and computerized tomographic imaging. Ionization detectors have been used only in CT appHcations. All detectors used in detection of x-ray radiation must be linear and have a maximum efficiency at the wavelength of the x-ray photon to be detected. [Pg.50]

Scintillation detectors are substances which fluoresce when stmck by x-radiation. Scintillation can, therefore, serve to convert x-ray photons into visible or ultraviolet light. Scintillation materials include thaUium-activatedcrystals of sodium iodide, NaI(Tl), potassium iodide, KI(T1), or cesium iodide, CsI(Tl) crystals of stilbene (a, P-diphenylethylene) [588-59-0] and anthracene [120-12-7] bismuth germanium oxide [12233-56-6] ... [Pg.50]

A large number of radiometric techniques have been developed for Pu analysis on tracer, biochemical, and environmental samples (119,120). In general the a-particles of most Pu isotopes are detected by gas-proportional, surface-barrier, or scintillation detectors. When the level of Pu is lower than 10 g/g sample, radiometric techniques must be enhanced by preliminary extraction of the Pu to concentrate the Pu and separate it from other radioisotopes (121,122). Alternatively, fission—fragment track detection can detect Pu at a level of 10 g/g sample or better (123). Chemical concentration of Pu from urine, neutron irradiation in a research reactor, followed by fission track detection, can achieve a sensitivity for Pu of better than 1 mBq/L (4 X 10 g/g sample) (124). [Pg.200]

Position Sensitive Detectors. By replacing the scintillation detector in a conventional powder diffractometer with a Position Sensitive Detector (PSD), it is possible to speed data collection. For each x-ray photon received a PSD records the angle at which it was detected. Typically, a conventional scintillation detector records x-ray photons in a range of a few hundredths of a degree at a time. A PSD can measure many degrees (in 20) of a powder pattern simultaneously. Thus, for small samples, data collection, which could require hours with a conventional detector, could take minutes or even seconds with a PSD. [Pg.381]

The density section of the tool, also seen in Figure 4-281, uses a 1.7 curie (Ci) of 137-cesium (Ce) gamma ray source in conjunction with two gain-stabilized scintillation detectors to provide a high-quality, borehole compensated density measurement. [Pg.986]

The concrete block walls of the cell housing the generator tube and associated components are 1.7 meters thick. The facility also includes a Kaman Nuclear dual-axis rotator assembly for simultaneous transfer and irradiation of reference and unknown sample, and a dual Na iodide (Nal) scintillation detector system designed for simultaneous counting of activated samples. Automatic transfer of samples between load station to the rotator assembly in front of the target, and back to the count station, is accomplished pneumatically by means of two 1.2cm (i.d.) polyethylene tubes which loop down at both ends of the system and pass underneath the concrete shielding thru a pipe duct. Total one-way traverse distance for the samples is approx 9 meters. In performing quantitative analysis for a particular element by neutron activation, the usual approach is to compare the count rates of an unknown sample with that of a reference standard of known compn irradiated under identical conditions... [Pg.358]

A typical procedure for Na assay is One gram proplnt samples sealed in polyethylene vials are irradiated for at least seven hrs in the thermal column. In order to minimize any thermal neutron flux gradient, the samples are rotated uniaxially at 60 rpm. Following irradiation, the samples are allowed to decay for approx 15 hrs to permit all short-lived radioisotopes to decay to insignificance. The 1.369 MeV 7-photopeak of each sample is then counted for 10 min with a 7.6cm x 7.6cm Na iodide scintillation detector coupled to a 400-channel pulse-height analyzer... [Pg.363]

A sealed-tube neutron generator, utilizing the deuterium-tritium reaction is the source of fast (14 MeV) neutrons, and a 8 x 3 1 Nal scintillation detector, with three optically coupled photomultipliers, is used to measure the >ray signal... [Pg.381]

Some properties of the detectors most commonly used for transmission experiments are summarized in Table 3.2. Alternative counters are scintillation detectors based on Nal or plastic material that is attached to a photomultiplier, and solid-state detectors using silicon- or germanium-diodes. [Pg.38]


See other pages where Detectors scintillation detector is mentioned: [Pg.118]    [Pg.205]    [Pg.118]    [Pg.205]    [Pg.585]    [Pg.595]    [Pg.643]    [Pg.59]    [Pg.88]    [Pg.89]    [Pg.113]    [Pg.148]    [Pg.155]    [Pg.186]    [Pg.804]    [Pg.906]    [Pg.932]    [Pg.980]    [Pg.1088]    [Pg.57]    [Pg.481]    [Pg.482]    [Pg.482]    [Pg.320]    [Pg.376]    [Pg.379]    [Pg.382]    [Pg.228]    [Pg.972]    [Pg.67]    [Pg.369]    [Pg.370]    [Pg.371]    [Pg.383]    [Pg.384]    [Pg.386]    [Pg.270]   
See also in sourсe #XX -- [ Pg.69 ]




SEARCH



Amplifier scintillation detector

Analysis of Scintillation Detector Energy Spectra

Crystal scintillation detector

Damage scintillation detectors

Detector scintillation counter

Detector types scintillation counter

Flow scintillation detectors

Impurities scintillation detector

Ionizing radiation scintillating detector

Liquid scintillation detector

Lithium scintillator detectors

Multichannel analyser scintillation detector

Nal scintillator detectors

Nal/TL scintillation detector

Plastic scintillator radioisotope detector

Power supply scintillation detector

Resolution scintillation detectors

Scintillation Detector Array

Scintillation and Semiconductor y-Ray Detectors

Scintillation detector

Scintillation detector

Scintillation detector construction

Scintillation detector materials

Scintillation detector optical coupling

Scintillation detector requirements

Scintillation detector shape

Scintillation detectors alpha particle detection

Scintillation detectors calibration

Scintillation detectors components

Scintillation detectors detection efficiency

Scintillation detectors efficiency

Scintillation detectors energy resolution

Scintillation detectors experimental

Scintillation detectors neutron absorbers

Scintillation detectors particle detection

Scintillation detectors photomultiplier tubes

Scintillation detectors preamplifier

Scintillation detectors pulse height analyzers

Scintillation detectors radiation detection methods

Scintillation detectors scintillators

Scintillation detectors systems

Scintillation semiconductor detectors

Scintillator

Scintillator Detector Materials

Sodium iodide scintillation detector

Solid Scintillation Detectors in PET

© 2024 chempedia.info