Detection nonselective

Muns ENDOR mvolves observation of the stimulated echo intensity as a fimction of the frequency of an RE Ti-pulse applied between tlie second and third MW pulse. In contrast to the Davies ENDOR experiment, the Mims-ENDOR sequence does not require selective MW pulses. For a detailed description of the polarization transfer in a Mims-type experiment the reader is referred to the literature [43]. Just as with three-pulse ESEEM, blind spots can occur in ENDOR spectra measured using Muns method. To avoid the possibility of missing lines it is therefore essential to repeat the experiment with different values of the pulse spacing Detection of the echo intensity as a fimction of the RE frequency and x yields a real two-dimensional experiment. An FT of the x-domain will yield cross-peaks in the 2D-FT-ENDOR spectrum which correlate different ENDOR transitions belonging to the same nucleus. One advantage of Mims ENDOR over Davies ENDOR is its larger echo intensity because more spins due to the nonselective excitation are involved in the fomiation of the echo. [Pg.1581]

Conductivity detectors, commonly employed in ion chromatography, can be used to determine ionic materials at levels of parts per million (ppm) or parts per bUHon (ppb) in aqueous mobile phases. The infrared (ir) detector is one that may be used in either nonselective or selective detection. Its most common use has been as a detector in size-exclusion chromatography, although it is not limited to sec. The detector is limited to use in systems in which the mobile phase is transparent to the ir wavelength being monitored. It is possible to obtain complete spectra, much as in some gc-ir experiments, if the flow is not very high or can be stopped momentarily. [Pg.110]

The SIMS analytical ion signal of a specific element or isotope also can be enhanced by selective ionization of particular atoms, and the detection limit for that element thereby improved. This mode of SNMS is important to specific applications, but it lacks the generality inherent in nonselective SNMS methods. The focus of this article will be on the methods for obtaining complete, accurate, and matrix-independent compositions of chemically complex thin-film structures and materials. [Pg.573]

Compared with the sensors for atoms and radicals, the calibration of EEP sensors is also somewhat specific. To calibrate detectors of atomic particles, it will be generally enough to determine (on the basis of sensor measurements) one of the literature-known constants, say, tiie energy of parent gas dissociation on a hot Hlament. For the detection of EEPs when nonselective excitation of gas is taking place, in order to calibrate a sensor use should be made of some other selective methods detecting EEPs. The calibration method may be optical spectroscopy, chemical and optic titration, emission measurements, etc. [Pg.299]

When photobiotin is irradiated in the presence of DNA the reaction process nonselectively couples a biotin label to every 100-200 base residues. The result is an oligonucleotide probe detectable by the use of (strept)avidin conjugates. The uses of photobiotin for DNA or RNA modification are summarized in Chapter 11, Section 4. [Pg.987]

GC is coupled with many detectors for the analysis of pesticides in wastewater. At the present time the most popular is GC-MS, which will be discussed in more detail later in this section. The flame ionization detector (FID) is another nonselective detector that identifies compounds containing carbon but does not give specific information on chemical structure (but is often used for quantification because of the linear response and sensitivity). Other detectors are specific and only detect certain species or groups of pesticides. They include electron capture,nitrogen-phosphorus, thermionic specific, and flame photometric detectors. The electron capture detector (ECD) is very sensitive to chlorinated organic pesticides, such as the organochlorine compounds (OCs, DDT, dieldrin, etc.). It has a long history of use in many environmental methods,... [Pg.59]

Seo et al. (1999) used a planar optic biosensor that measures the phase shift variation in refractive index due to antigen binding to antibody. In this method, they were able to detect S. enterica serovar T) himurium with a detection limit of 1 x 10 cfu/ml. When chicken carcass fluid was inoculated with 20 cfu/ml, the sensor was able to detect this pathogen after 12 h of nonselective enrichment. A compact fiber optic sensor was also used for detection of S. T) himurium at a detection limit of 1 X 10" cfu/ml (Zhou et al., 1997, 1998) however, its efficacy with food samples is unproven. Later, Kramer and Lim (2004) used the fiber optic sensor, RAPTOR , to detect this pathogen from spent irrigation water for alfalfa sprouts. They showed that the system can be used to detect Salmonella spiked at 50 cfu/g seeds. An evanescent wave-based multianalyte array biosensor (MAAB) was also employed for successful testing of chicken excreta and various food samples (sausage, cantaloupe, egg, sprout, and chicken carcass) for S. T) himurium (Taitt et ah, 2004). While some samples exhibited interference with the assay, overall, the detection limit for this system was reported to be 8 x 10 cfu/g. [Pg.12]

RI detectors measure this deflection, and are sensitive to all analytes that have a different R1 than the mobile phase. There are two major limitations First, Rl detectors are very sensitive to changes in the temperature, pressure, and flow rate of the mobile phase, and so these measurement conditions must be kept stable in order to obtain low background levels. Second, Rl detectors are incompatible with chromatographic separations using gradient elution. Furthermore, because Rl detectors are nonselective, they must be used in conjunction with other detection methods if specificity is required. Nevertheless, they have found wide application in isocratic chromatographic analysis for analytes that do not have absorptive, fluorescent, or ionic properties, such as polymers and carbohydrates. [Pg.215]

With analytical methods such as x-ray fluorescence (XRF), proton-induced x-ray emission (PIXE), and instrumental neutron activation analysis (INAA), many metals can be simultaneously analyzed without destroying the sample matrix. Of these, XRF and PEXE have good sensitivity and are frequently used to analyze nickel in environmental samples containing low levels of nickel such as rain, snow, and air (Hansson et al. 1988 Landsberger et al. 1983 Schroeder et al. 1987 Wiersema et al. 1984). The Texas Air Control Board, which uses XRF in its network of air monitors, reported a mean minimum detectable value of 6 ng nickel/m (Wiersema et al. 1984). A detection limit of 30 ng/L was obtained using PIXE with a nonselective preconcentration step (Hansson et al. 1988). In these techniques, the sample (e.g., air particulates collected on a filter) is irradiated with a source of x-ray photons or protons. The excited atoms emit their own characteristic energy spectrum, which is detected with an x-ray detector and multichannel analyzer. INAA and neutron activation analysis (NAA) with prior nickel separation and concentration have poor sensitivity and are rarely used (Schroeder et al. 1987 Stoeppler 1984). [Pg.210]

The ratio of the three products depends on the reacting silane and alkyne, the catalyst, and the reaction conditions. Platinum catalysts afford the anti-Markovnikov adduct as the main product formed via syn addition.442- 146 Rhodium usually is a nonselective catalyst404 and generally forms products of anti addition.447 151 Minor amounts of the Markovnikov adduct may be detected. Complete reversal of stereoselectivity has been observed.452 [Rh(COD)Cl]2-catalyzed hydrosilylation with Et3SiH of 1-hexyne is highly selective for the formation of the Z-vinylsilane in EtOH or DMF (94-97%). In contrast, the E-vinylsilane is formed with similar selectivity in the presence of [Rh(COD)Cl]2-PPh3 in nitrile solvents. [Pg.325]

In this manner, a nearly universal and very nonselective detector is created that is a compromise between widespread response and high selectivity. For example, the photoionization detector (PID) can detect part-per-billion levels of benzene but cannot detect methane. Conversely, the flame ionization detector (FID) can detect part-per-billion levels of methane but does not detect chlorinated compounds like CCl very effectively. By combining the filament and electrochemical sensor, all of these chemicals can be detected but only at part-per-million levels and above. Because most chemical vapors have toxic exposure limits above 1 ppm (a few such as hydrazines have limits below 1 ppm), this sensitivity is adequate for the initial applications. Several cases of electrochemical sensors being used at the sub-part-per-million level have been reported (3, 16). The filament and electrochemical sensor form the basic gas sensor required for detecting a wide variety of chemicals in air, but with little or no selectivity. The next step is to use an array of such sensors in a variety of ways (modes) to obtain the information required to perform the qualitative analysis of an unknown airborne chemical. [Pg.303]


See other pages where Detection nonselective is mentioned: [Pg.562]    [Pg.562]    [Pg.565]    [Pg.185]    [Pg.501]    [Pg.96]    [Pg.109]    [Pg.439]    [Pg.329]    [Pg.921]    [Pg.211]    [Pg.241]    [Pg.25]    [Pg.42]    [Pg.47]    [Pg.315]    [Pg.900]    [Pg.137]    [Pg.383]    [Pg.570]    [Pg.930]    [Pg.110]    [Pg.372]    [Pg.363]    [Pg.381]    [Pg.25]    [Pg.155]    [Pg.14]    [Pg.175]    [Pg.333]    [Pg.109]    [Pg.373]    [Pg.282]    [Pg.192]    [Pg.590]    [Pg.383]    [Pg.570]    [Pg.207]    [Pg.253]    [Pg.436]   