Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Defibrillator leads extraction

Lakkireddy DR, Verma A, Wilkoff BL (2005) Current concepts in intravascular pacemaker and defibrillator lead extraction. In Wang, Paul J (ed) New arrhythmia technologies. Gerald V. Naccarelli, Michael R, Rosen NA, Mark Estes III, David L. Hayes, David E. Haines (co-eds). Black-well-Futura Publishing, Malden pp 124-133... [Pg.46]

Verma A, Wilkoff BL (2004) Intravascular pacemaker and defibrillator lead extraction a state-of-the-art review. Heart Rhythm l(6) 739-745... [Pg.80]

Table 6 4Implantable cardioverter-defibrillator lead extraction... [Pg.107]

Saad EB, Saliba WI, Schweikert RA et al (2003) Nonthoracotomy implantable defibrillator lead extraction results and comparison with extraction of pacemaker leads. Pacing Clin Electrophysiol 26 1944-1950. [Pg.113]

Hamid S, Arujuna A, Ginks M et al (2010) Pacemaker and defibrillator lead extraction predictors of mortality during follow-up. Pacing Clin Electrophysiol 33(2) 209-216... [Pg.114]

Kutalek SP (2004) Pacemaker and defibrillator lead extraction. Curr Opin Cardiol 19 19-22... [Pg.135]

Defibrillator lead extraction is much more challenging when compared to pacemaker leads. This is because defibrillator leads are larger in diameter and have coils that can result in exuberant encapsulating fibrous scar attachment to endovascular structures. The defibrillator coils tend to promote dense fibrosis and fibrous bands that can attach to venous and myocardial structures. The extraction of such leads call for the use of larger extraction sheaths and... [Pg.309]

Multiluminal design has allowed ICD leads to be more resistant, reliable, and thinner, and these characteristics are obviously very useful at the time of implantation but also in case of lead extraction. A critical point in lead structure is where different materials are crimped or connected together as conductors to electrodes or defibrillation coils. Detachment at this level is possible while attempting lead extraction. [Pg.16]

The instruments necessary for overcoming these complications are prevention and treatment. The first is related to durability and reliability of pacing/defibrillating leads and the second to their extractability profile. Both issues apply to each component of a pacing/defibrillating lead. [Pg.20]

Fig 1 33 Tenacious adhesion of superior vena cava along the proximal coil of an implantable cardioverter-defibrillator lead with a free-floating filar coil design. Note coil despiralization in the proximal end as a consequence of lead extraction... [Pg.22]

To approach an extraction procedure with more consciousness, it is important to be aware of the complications related to human body response after implantation of a pacing or defibrillating lead [46]. When a transvenous permanent lead is implanted, it stays in close contact with some points of the venous endothelium and endocardium. At these points, the lead may be responsible of chronic traumatism on the endothelium/endocardi-um, causing an inflammatory response of the vessel or endocardial wall, with thrombus formation and subsequent scarring [47-49]. [Pg.28]

WilkoffBE, BelottPH, Love CJ et al (2005) Improved extraction of ePTEE and medical adhesive modified defibrillation leads from the coronary sinus and great cardiac vein. Pacing Clin Electrophysiol 28(3) 205-211... [Pg.33]

Korley VJ, Hallet N, Daoust M, Epstein LM (2000) A novel indication for transvenous lead extraction upgrading implantable cardioverter defibrillator systems. J Interv Card Electrophysiol 4(3) 523-528... [Pg.34]

Lead removal is removal of a pacing or defibrillator lead using any technique. It includes two completely different procedures lead explant and lead extraction. Lead explant is the removal of a lead using simple traction techniques, which is usually possible for leads implanted for less than 1 year. Lead extraction is removal of a lead implanted for more than 1 year or that requires the assistance of specialized equipment in order to be removed. Lead extraction is by far the more complex procedure. As it carries some risks for the patient, clear indications, expertly trained personnel, adequate tools, and appropriate environment and facilities are mandatory for its safe removal [1, 2]. [Pg.35]

Love CJ, Wilkoff BL, Byrd CL et al (2000) Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads indications, facilities, training. Pacing Clin Electrophysiol 23(4) 544-551... [Pg.45]

Del Rio A, Anguera I, Miro JM et al (2003) Surgical treatment of pacemaker and defibrillator lead endocarditis. Impact of electrode lead extraction on outcome. Chest 124 1451-1459... [Pg.46]

Byrd CL (2007) Managing device-related complications and transvenous lead extractions. In Ellenbogen KA, Kay GN, Wilkoff BL, Lau CP (eds.) Clinical cardiac pacing, defibrillation and resynchronization therapy (3rd edn) Saunders, Philadelphia, pp 855-930... [Pg.46]

ECG, electrocardiogram 02% monitoring blood oxygen saturation ICD, implantable cardiac defibrillator PM, pacemaker TTE, transthoracic echocardiography TLE, transvenous lead extraction... [Pg.52]

Bracke F, Meijer A, Van Gelder B (2002) Extraction of pacemaker and implantable cardioverter defibrillator leads patient and lead characteristics in relation to the requirement of extraction tools. Pacing and Clin Electrophysiol 25 1037-1040... [Pg.56]

Vassilikos VP et al (1999) Percutaneous extraction of transvenous defibrillator leads using the VascoExtor pacing lead removal system. J Interv Card Electrophysiol 3(3) 247-251... [Pg.80]

Hauser RG et al (2010) Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction. Europace 12(3) 395 01... [Pg.80]

Bongiomi MG et al (2005) Pacing and implantable cardioverter-defibrillator transvenous lead extraction. Ital Heart J6(3) 261-266... [Pg.80]

Moon MR et al (2002) Laser-assist during extraction of chronically implanted pacemaker and defibrillator leads. Ann Thorac Surg 73(6) 1893-1896... [Pg.80]

Scott PA et al (2009) Extraction of pacemaker and implantable cardioverter defibrillator leads a single-centre study of electrosurgical and laser extraction. Europace 11(11) 1501-1504... [Pg.82]

Kantharia BK et al (2000) Feasibility, safety, and determinants of extraction time of percutaneous extraction of endocardial implantable cardioverter defibrillator leads by intravascular countertraction method. Am J Cardiol 85(5) 593-597... [Pg.82]


See other pages where Defibrillator leads extraction is mentioned: [Pg.309]    [Pg.310]    [Pg.309]    [Pg.310]    [Pg.3]    [Pg.20]    [Pg.20]    [Pg.20]    [Pg.22]    [Pg.22]    [Pg.29]    [Pg.44]    [Pg.45]    [Pg.52]    [Pg.59]    [Pg.60]    [Pg.83]    [Pg.107]   


SEARCH



Defibrillation

Defibrillator leads

Defibrillator leads using extraction sheaths

Defibrillators

© 2024 chempedia.info