Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Data collection step

The three phases of the run can be seen clearly the heating step corresponds to the sharp rise on the left-hand side, the data collection step corresponds to the flat part of the curve, and the cooling step is seen as the final part of the curve. [Pg.64]

After the user verifies the chromatograph settings the specimen database updating program creates the run queue. The run queue contains one record for each data collection step in the upcoming batch. The run queue building task also checks for enough free disk space to hold the expected data files. [Pg.135]

Additional software has been developed to merge data from various data collection steps and to model the data using suitable statistical distribution functions. We are working on software to perform corrections for absorption, specimen shape, and misalignment. Library routines for 2-diraensional data smoothing and integration are being adapted to the calculation of orientation functions and other moments of the probability distributions. [Pg.151]

In phase III of the data collection step, companies which produce or import existing substances in quantities between 10 and 1000 tons per year (LPVCs or Low Production Volume Chemicals) were required to submit a reduced data set by 4 June 1998. [Pg.35]

Another factor which influences the speed in performing an analysis is calibration of the instrument. Calibration is especially time-consuming in cases where different elements are run on every analysis but even in cases where the same elements are determined time after time, the frequency of instrument calibration required to maintain a desired level of accuracy is an important consideration. Since manual data collection is not feasible in multielement determinations, the ideal system would undoubtedly be computerized. The computer would handle all data collection steps, the construction of calibration curves by mathematical curve-fitting methods, and the calculation of concentrations from these curves. [Pg.29]

Data collection step 63 de Broglie hypothesis 2 Debye 272 del 8... [Pg.175]

Data Collection During the data collection step, the required data are collected and analysed to determine if there are any obvious problems with the data set, such as missing data, faulty sensors, faulty values, or multiple operating modes. The framework presented in Fig. 6.3 assumes that a separate experiment will be designed in order to obtain the data required for system identification. In industry, the ability to perform such experiments can be limited due to various factors, including safety, economic, or reluctance on the part of the plant operators. Instead, historical data from the data historian are extracted and preprocessed to determine their usefulness for the given problem. [Pg.291]

Traditionally, SIMS is subdivided into two broad areas according to the volume probed per analytical cycle. An analytical cycle represents a single data collection step, which may be repeated multiple times. This data collection step may be in the form of an intensity data point, mass spectra, or a spatial image. As will be covered in Section 5.1.1.3, multiple such steps are required in the collection of a depth profile. The areas into which SIMS is subdivided are otherwise referred to as Static SIMS and Dynamic SIMS. [Pg.148]

There is a two-step process to predict the detectable detail - object diameter diagram. The optimal data collection parameter settings to maximise SNRAproj for the defect to the surrounding material - Optimal... [Pg.213]

In many molecular dynamics simulations, equilibration is a separate step that precedes data collection. Equilibration is generally necessary lo avoid introducing artifacts during the healing step an d to en su re th at the trajectory is aciii ally sim u laiin g eq u i librium properties. The period required for equilibration depends on the property of Interest and the molecular system. It may take about 100 ps for the system to approach equilibrium, but some properties are fairly stable after 1 0-20 ps. Suggested tim es range from. 5 ps to nearly 100 ps for medium-si/ed proteins. [Pg.74]

HyperChem run s the molecular dynain ics trajectory, averaging and analyzing a trajectory and creating the Cartesian coordinates and velocities, fhe period for reporting these coordinates and velocities is th e data collection period. At-2. It is a m iiltiplc of the basic time step. At = ii At], and is also referred to as a data step. The value 1I2 is set in the Molecular Dynamics options dialog box. [Pg.318]

At, etc. The Snapshot period is specified 111 the Snapshot dialog bo by n, data steps, i.e. as a ni ii Itiple of the data collection period, At4 = n4 i3t2. [Pg.319]

TlyperCi hem updates the screen diirin g a trajectory at regular in ter-vals so yon can visiiali/e the irajectory. Since this screen update may slow down a trajectory If it occurs too frequently, yon c.an specify the duration of the Screen Refresh period At.,. The screen updates at ilines tQ, Iq + Atj, to + 2Atj, etc. The Screen Refresh period is specified in the Molecular Dynamics options dialog box by n 5 data steps, i.e. as a m iiliiplc of the data collection period, At5 = n 5 At2-... [Pg.319]

Decision Process. In many cases, the decision regarding the need for exposure reduction measures is obvious and no formal statistical procedure is necessary. However, as exposure criteria are lowered, and control becomes more difficult, close calls become more common, and a logical decision-making process is needed. A typical process is shown in Eigure 2. Even when decision making is easy it is useful to remember the process and the assumptions involved. Based on an evaluation, decisions are made regarding control. The evaluation and decision steps caimot be separated because the conduct of the evaluation, the strategy, measurement method, and data collection are all a part of the decision process. [Pg.108]

Step 5.4 Record Information on Process Flow Sheets. The input data collected for the material balance can be recorded on the process flow diagram, and in tabular form on a spreadsheet. [Pg.366]

In addition to the data collected in Step 1 of the basic method, the following data are needed ... [Pg.212]

This section sets out a step-by-step procedure for setting up a data collection system, including the important issues of gaining workforce acceptance and management support. [Pg.249]

The STEP procedure, described by Hendrick and Benner (1987), was developed from a research program on incident investigation methods. STEP is based on the mulHple events sequence method and is an investigative process which structures data collection, representation, and analysis. [Pg.274]

Data collected during these process variable scans indicate that more C02 than expected was being formed (Figure 4). Selectivity to C02 reached a maximum of 5-10% at about 90-95% conversion. At higher conversions, the C02 level is reduced by reverse shift and subsequent methanation of CO or by direct methanation of C02. This selectivity to C02 can be eliminated by cofeeding small amounts of C02 (3-5%). Since multiple C02 absorbers are required in the commercial SNG plant, one or more could be relocated downstream of the methanation step. This could offer some economic advantages since C02 absorption would now occur at higher concentration and pressure and at lower total gas flow. [Pg.165]


See other pages where Data collection step is mentioned: [Pg.64]    [Pg.135]    [Pg.64]    [Pg.394]    [Pg.135]    [Pg.325]    [Pg.357]    [Pg.604]    [Pg.12]    [Pg.41]    [Pg.95]    [Pg.228]    [Pg.64]    [Pg.135]    [Pg.64]    [Pg.394]    [Pg.135]    [Pg.325]    [Pg.357]    [Pg.604]    [Pg.12]    [Pg.41]    [Pg.95]    [Pg.228]    [Pg.1629]    [Pg.318]    [Pg.318]    [Pg.319]    [Pg.110]    [Pg.2166]    [Pg.377]    [Pg.28]    [Pg.296]    [Pg.233]    [Pg.97]    [Pg.91]   
See also in sourсe #XX -- [ Pg.63 ]

See also in sourсe #XX -- [ Pg.63 ]




SEARCH



Data collection

Step data collection sequence

Step scan data collection

© 2024 chempedia.info