Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Data analysis time-consuming

In addition, behavior, including mimic and gross body movements, may be videotaped. However, the analysis of such data is time consuming and is, therefore, not often performed by engineering psychologists. [Pg.22]

A further challenge is the efficient interpretation of MALDI imaging data in the histological context, which is of particular importance in clinical studies where large numbers of specimen are analyzed. Peak-by-peak interpretation of MALDI imaging data is time-consuming and tedious. In fact, the detailed analysis of numerous tissue sections by a pathologist, as necessary in clinical studies, is not feasible due to time constraints. [Pg.386]

The ability of partial least squares to cope with data sets containing very many x values is considered by its proponents to make it particularly suited to modern-day problems, where it is very easy to compute an extremely large number of descriptors for each compound (as in CoMFA). This contrasts with the traditional situation in QSAR, where it could be time-consuming to measure the required properties or where the analysis was restricted to traditional substituent constants. [Pg.727]

The maintenance of analytical instmmentation requkes trained personnel and is a time-consuming task (39,40). An additional problem is the necessity of frequentiy checking the caUbration of the analysis instmmentation and recahbrating if requked. Stand-alone data gathering instmmentation, once common in pilot plants, has been vktuaHy replaced in all but the simplest pilot plants by a data gathering computer, usually used for process control as well. [Pg.42]

In the analysis of vibration data there is often the need to transform the data from the time domain to the frequency domain or, in other words, to obtain a spectrum analysis of the vibration. The original and inexpensive system to obtain this analysis is the tuneable swept-filter analyzer. Because of inherent limitations of this system, this process, despite the use of automated sweep, is time-consuming when analyzing low frequencies. When the spectra data needs to be digitized for computer inputing, there are further limitations in capability of tuneable filter-analysis systems. [Pg.670]

Over the years there have been many attempts to simulate the behaviour of viscoelastic materials. This has been aimed at (i) facilitating analysis of the behaviour of plastic products, (ii) assisting with extrapolation and interpolation of experimental data and (iii) reducing the need for extensive, time-consuming creep tests. The most successful of the mathematical models have been based on spring and dashpot elements to represent, respectively, the elastic and viscous responses of plastic materials. Although there are no discrete molecular structures which behave like the individual elements of the models, nevertheless... [Pg.84]

Finally, one can also perform a complete analysis by integrating the TPD curves, and finding sets of rates and temperatures corresponding to the same coverage. Such data can be plotted in the form of Arrhenius plots. Hoivever, this is both tedious and time-consuming, and has rarely been performed. [D.A. King, Surf. Sci. 47 (1975) 384]. [Pg.278]

Faraday collector, simultaneously with U, U and U during the first sequence. This shortens the analysis routine, consuming less sample. Ion beam intensities are typically larger in MC-ICPMS than in TIMS due to the ease with which signal size can be increased by introducing a more concentrated solution. While this yields more precise data, non-linearity of the low-level detector response and uncertainties in its dead-time correction become more important for larger beam intensities, and must be carefully monitored (Cheng et al. 2000 Richter et al. 2001). [Pg.48]

The inventory tasks is to collect environmentally important information about relevant processes involved in the product system. Inventory collects information about unit processes at first and subsequently, an inventory of inputs and outputs of the system and its surroundings is carried out. The goal is the identification and quantification of all elementary flows associated with product system. Inventory analysis is the nature of the technical implementation of LCA studies. It is an essential part of a study, has high demands for data availability, practical experience in modelling product systems and, in the case of using database tools, it is necessary to master them perfectly and to understand their function [46]. The inventory phase principle is data collection that is used to quantify values of the elementary flows. This phase represents a major practical part of the LCA study, time consuming and with demands for data availability and author s experience with modelling product system studies [47],... [Pg.268]

The titration of metal ions in alcohol solvents28 follows the same sort of rules as titrations of metal ions in water29 but poses additional problems due to the lower polarity that increases ion pairing and oligomerization of the metal ions. We have performed several such titrations with the analysis of the potentiometric data depending on the level of information one requires. More complete and time-consuming analyses are reserved for the most effective catalytic metals, namely La3 +, and for the transition metal ion Zn2+ and Cu2+ along with some simple complexes of the latter two which we describe a little later. For the other metal ions described in our titration papers,7,8 we only present the data in terms of the... [Pg.278]


See other pages where Data analysis time-consuming is mentioned: [Pg.291]    [Pg.591]    [Pg.304]    [Pg.13]    [Pg.613]    [Pg.282]    [Pg.294]    [Pg.197]    [Pg.160]    [Pg.290]    [Pg.143]    [Pg.564]    [Pg.446]    [Pg.317]    [Pg.320]    [Pg.164]    [Pg.31]    [Pg.323]    [Pg.66]    [Pg.348]    [Pg.146]    [Pg.78]    [Pg.144]    [Pg.140]    [Pg.303]    [Pg.156]    [Pg.270]    [Pg.328]    [Pg.410]    [Pg.180]    [Pg.72]    [Pg.8]    [Pg.25]    [Pg.132]    [Pg.43]    [Pg.9]    [Pg.373]    [Pg.461]    [Pg.328]    [Pg.172]    [Pg.238]   
See also in sourсe #XX -- [ Pg.44 ]




SEARCH



Time consuming

© 2024 chempedia.info