Darkfield microscopy

Darkfield microscopy is one of the oldest modes of microscopy. Here, axial rays from the condenser are prevented from entering the objective, through the use of an opaque stop placed in the condenser, while peripheral light illuminates the specimen. Thus, the specimen is seen lighted against a dark Held. [Pg.64]

Reflected light darkfield microscopy (epifluorescence) can be used to visuaUze silver graius on darkly colored digoxigenin-labeled cells and obtain better contrast... [Pg.88]

Grow B. burgdorferi cultures to mid- to late-exponential phase (approximately 5-9 X 10 cells/mL as determined by darkfield microscopy using a Petroff-Hausser chamber) (see Note 3). Usually a 100 mL culture provides sufficient cell numbers for about two transformations. [Pg.90]

Unlike darkfield microscopy, which is primarily used for imaging at the cell-surface level, OCT is an imaging modality that can be used to acquire optical images of samples at different depths, up to several millimeters with sub-micrometer resolution. OCT works similarly to ultrasound, but utilizes the reflections of light through tissue to generate images rather than reflections of sound waves. [Pg.641]

The capability of TFCI technique to measure nanometric separations has been demonstrated earlier [13]. In order to make sure that this technique can provide credible estimation of the real contact area, the contact topography was also observed by darkfield microscopy. Figure 2 shows comparison of the results given by both techniques for 30 x 70 pm part of lightly loaded contact between the rough ball and the glass disc. The dark areas represent... [Pg.552]

Light microscopy allows, in comparison to other microscopic methods, quick, contact-free and non-destmctive access to the stmctures of materials, their surfaces and to dimensions and details of objects in the lateral size range down to about 0.2 pm. A variety of microscopes with different imaging and illumination systems has been constmcted and is conunercially available in order to satisfy special requirements. These include stereo, darkfield, polarization, phase contrast and fluorescence microscopes. [Pg.1655]

But darkfield conventional transmission electron microscopy can now reveal monatomic steps directly, as the micrograph in Fig. 12 shows (71). Using this kind of approach it should be possible to ascertain quantitatively the extent of the interaction between a catalyst and its underlying support. [Pg.450]

Froseh, D., Westphal, C and Bauer, R. (1987). Darkfield electron microscopy of unstained biological materials embedded in Nanoplast. J. Microsc. (Oxford) 147(3), 313-321. [Pg.184]

The research of the structure of the radiation surface, of the etched metallographic section (direct and seating metallographic section) of the modified samples were carried out by the methods of electron scanning and transmission electron microscopy. X-ray structure analysis. The change mechanical properties of a material were characterized by microhardness. The accuracy of the measurement is amounted to 7%. For phase identification diffraction analysis with the use of darkfield method and subsequent indicating of microelectronograms was is used. [Pg.149]


See other pages where Darkfield microscopy is mentioned: [Pg.530]    [Pg.74]    [Pg.92]    [Pg.591]    [Pg.640]    [Pg.640]    [Pg.640]    [Pg.640]    [Pg.398]    [Pg.398]    [Pg.157]    [Pg.352]    [Pg.92]    [Pg.530]    [Pg.74]    [Pg.92]    [Pg.591]    [Pg.640]    [Pg.640]    [Pg.640]    [Pg.640]    [Pg.398]    [Pg.398]    [Pg.157]    [Pg.352]    [Pg.92]    [Pg.279]    [Pg.308]    [Pg.96]    [Pg.1721]   
See also in sourсe #XX -- [ Pg.90 , Pg.92 ]

See also in sourсe #XX -- [ Pg.90 , Pg.92 ]