This section summarizes the uniform United States and Canadian standards for cylinder valve inlet connections in which a threaded joint is used to attach cylinder valves to cylinders and containers. It is recognized that valve inlet and... [Pg.144]

For further information on cylinder valve inlet connections and other thread types presently in use, that is, special gas taper (SGT) threads and national gas straight (NGS) threads, refer to... [Pg.152]

Cylinder valve inlet and outlet connections on compressed air containers offered in transportation must conform to CGA V-1, American National, Canadian, and Compressed Gas Association Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connections, and CGA V-7, Standard Method of Determining Cylinder Valve Outlet Connections for Industrial Gas Mixtures. [9] and [10]... [Pg.229]

CGA Pamphlet V-l-87, American Canadian and Compressed Gas Association Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connections, ANSI, B57.1 CSA B96, 1987. [Pg.618]

Regulators are used to reduce cylinder supply pressure to a lower use pressure. As stated previously, hydrogen uses a CGA 350 cylinder valve. This requires a CGA 350 outlet connection on the regulator. Be sure that the regulator you purchase for cylinder use has a CGA 350 outlet connection. In line hydrogen regulators can have any variety of connections, but cylinder regulators must have the CGA 350 inlet connector. [Pg.302]

Already performance car use inlet pipe of variable accoustic lengths. A well localised butterfly can be automatically actuated, offering two and sometimes tliree different design lengths. The origin of the variation of the maximum mass of air trapped inside a cylinder, a quantity directly coimected to the torque, is easy to understand. Imagine a pipe closed at 1 by a valve and connected to the atmosphere at 0 (fig.l). If you create a brief suction at I you will observe your... [Pg.34]

Compressed Gas Cylinder Valve Outlet and Inlet Connections Refrigerant Expansion Valves... [Pg.343]

The cell was equipped with a pressure gauge mounted in the stainless steel line after the air cylinder, a stainless steel reservoir with a volume of 2 L, a pressure release valve, a fluid inlet and oudet connection, a pressure safetj- valve, and a refill opening on top of the reservoir. On top of the stirred cell, a fluid inlet connection, a pressure release valve and a temperature probe fitting were mounted. The temperature was measured with a PT 100 probe, connected to a Kane-May KM 330 indicator. [Pg.98]

A cylinder of the helium to be analyzed is connected to the inlet of the apparatus through a special adapter valve attached to the cylinder. This is a "needle-nose" valve and is much better for regulatingflow than the cylinder valves. This... [Pg.402]

In the United States and several other countries, the industry has developed standardized cylinder valve outlet and inlet connections, transfer connections, and regulator connections for specific types and groups of compressed gases to prevent the misapplication of these potentially hazardous materials. [Pg.20]

Container valve connections that do not fit must not be forced. Threads on regulator connections or other auxiliary requirements must match those on the container valve outlet. The valve outlet connection should conform to recognized standards such as ANSI/CGA V-1, American National, Compressed Gas Association Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connections [14]. However, it must be acknowledged that connections other than those found in ANSI/CGA V-1 may exist. If a user chooses such a connection, extreme care must be taken to ensure that such connections do not cross-connect with existing connections in ANSI/CGA V-1, and that they have been properly engineered for the intended gas service and pressure. The threads on a cylinder valve outlet, as well as on regulators and other ancillary equipment, should be examined at frequent intervals to ensure they are clean and undamaged. [Pg.20]

While no CGA standard exists for high-pressure station (manifold) connections, cylinder valves with X "inch, /2-inch, or 4-inch NGT inlet connections are commonly used with an appropriate CGA outlet connection for the application. [Pg.153]

Valve inlet The portion of the valve body that connects to the cylinder. [Pg.638]

There are a number of different types of cylinder valves affixed to the cylinders that are deliverd to users. Regulators are attached directly to these cylinder valves by the user. Four commonly used types of cylinder valves are illustrated in Figs. 4-6 through 4-9. Many valve outlet and inlet connections have been standardized by the Compressed Gas Association for the different families of gases to prevent the interchange of regulator equipment between gases which are not compatible. These standardized connections have been adopted by the American National Standards Institute and the Canadian... [Pg.49]


See other pages where Cylinder valve inlet connections is mentioned: [Pg.137]    [Pg.144]    [Pg.146]    [Pg.133]    [Pg.140]    [Pg.140]    [Pg.137]    [Pg.144]    [Pg.146]    [Pg.133]    [Pg.140]    [Pg.140]    [Pg.491]    [Pg.304]    [Pg.2]    [Pg.2]    [Pg.491]    [Pg.858]    [Pg.126]    [Pg.403]    [Pg.676]   