Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Cylinder sides

To address this gap in understanding, the surface specific nonlinear vibrational spectroscopy, sum frequency generation (SFG) has been applied to study the hexagonal ice surface, Ih. The Ih crystalline form is chosen as the focus of this work because it is the stable form of ice for ambient conditions on Earth. Further, the most abundant exposed face is the hexagonal or basal face. The second most abundant face consists of the cylinder sides, also called the prism face. This work examines both of these common faces. [Pg.192]

Cylinders connected to systems in the laboratory must always be strapped firmly to a support to ensure that they do not fall over. Not only is there a risk of breaking the cormection on the cylinder side of the regulator valve, with the concomitant risk of the cylinder becoming a missile, but the connection to the system also may be broken so that gas will escape from the low pressure side of the regulator. If the amount of gas to be stored in the laboratory is substantial, it may be preferable to pipe the gas in from a remote outside storage area with control valves located both outside and within the laboratory. [Pg.320]

Cylinder side walls and bottoms must be in a condition that allows an adequate view of the metal surface. If paint or other material has ac-... [Pg.177]

Bulges on the cylinder side wall can be measured by comparing a series of circumferential measurements using a pi-tape. [Pg.180]

Bulges in the head and also in some cases on the side wall can be measured by comparing a series of measurements of the peripheral distance between the valve spud and the center seam or an equivalent fixed location on the cylinder side wall. [Pg.180]

During the filling process there should be a check for the absence of heat of compression by placing a bare hand on each cylinder side wall. A cylinder s side wall that is colder than other cylinders on the manifold indicates that the cylinder is not being filled at the same rate as the other cylinders. The valve must be closed and not reopened on any cylinder that does not warm up from heat of compression. Such cylinders should be marked and set aside for further evaluation upon completion of the filling operation for that rack of cylinders. [Pg.189]

FIG. 32 Side view of the measurement of critical height using circular cylinder side plates are fixed on the ends of the cylinder to maintain the two-dimensionality of the meniscus. [Pg.425]

Determine flame surfiicc area (commonly use only the cylinder side area). [Pg.216]

The oil-film pressure distribution shown in Figurel 1(a) is almost symmetrical when the cylinder gas pressure is 5MPa or lower. However, when the gas pressure exceeds 5MPa, the oil-film pressure distribution becomes unsymmetrical with the peak shifted to the combustion cylinder side. [Pg.400]

Assume that an object needed with the refractive index gradient profile shown in Figime 66, where the abscissa axis represents the distance from the cylinder side to its center, and the ordinate axis is the difference in the refractive index. [Pg.59]

Add fluid along cylinder side, leave to sediment for a few minutes and remove possible particles at the fluid surface. [Pg.510]

This paper deals with the control of weld depth penetration for cylinders in gold-nickel alloy and tantalum. After introducing the experimental set-up and the samples description, the study and the optimization of the testing are presented for single-sided measurements either in a pulse-echo configuration or when the pump and the probe laser beams are shifted (influence of a thermal phenomenon), and for different kind of laser impact (a line or a circular spot). First, the ultrasonic system is used to detect and to size a flat bottom hole in an aluminium plate. Indeed, when the width of the hole is reduced, its shape is nearly similar to the one of a slot. Then, the optimization is accomplished for... [Pg.693]

Where helical secondaiy structures are represented by the cylinder model, the /i-strand. structures are visualized by the ribbon model (see the ribbons in Figure 2-124c). The broader side of these ribbons is oriented parallel to the peptide bond. Other representations replace the flat ribbons with flat arrows to visualize the sequence of the primary structure. [Pg.134]

The extractor consists of a glass cylinder A, terminating at the base in the open tube B. Fused within the top of A as shown is another tube C, having a small hole D blow n in the side a fine glass tube leads from the base of C, rises about two-thirds of the height of the cylinder to E, and then returns past F into the open tube B. [Pg.38]

Represent the side chains as cylinders with a net interaction potential. [Pg.275]

The working out of these ideas will be illustrated by reference to a number of simple pore models the cylinder, the parallel-sided slit, the wedge-shape and the cavity between spheres in contact. [Pg.126]

For each group of pores, the pore volume 6v is related to the core volume by means of a model, either the cylinder or the parallel-sided slit as the case may be. Allowance is made for the succession of film thicknesses corresponding to the progressive thinning of the multilayer in each pore, as desorption proceeds. Thus for group i, with radius rf when the film thickness is tj j > i) and the core volume is the pore volume 6vf will be given by... [Pg.142]


See other pages where Cylinder sides is mentioned: [Pg.260]    [Pg.260]    [Pg.64]    [Pg.368]    [Pg.42]    [Pg.177]    [Pg.437]    [Pg.466]    [Pg.188]    [Pg.514]    [Pg.21]    [Pg.260]    [Pg.260]    [Pg.64]    [Pg.368]    [Pg.42]    [Pg.177]    [Pg.437]    [Pg.466]    [Pg.188]    [Pg.514]    [Pg.21]    [Pg.695]    [Pg.11]    [Pg.52]    [Pg.431]    [Pg.468]    [Pg.474]    [Pg.478]    [Pg.69]    [Pg.92]    [Pg.358]    [Pg.566]    [Pg.15]    [Pg.214]    [Pg.47]    [Pg.398]    [Pg.36]    [Pg.90]    [Pg.91]    [Pg.418]    [Pg.450]    [Pg.77]   