Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Cyclodextrins derivatized

Figure 6. Example of resolution of chiral drugs on immobilized /3-cyclodextrin derivatized with (S)-naph-thylethyl isocyanate leaving polar carbamoyl groups. Reprinted with permission from ref 62. Figure 6. Example of resolution of chiral drugs on immobilized /3-cyclodextrin derivatized with (S)-naph-thylethyl isocyanate leaving polar carbamoyl groups. Reprinted with permission from ref 62.
Enantiomeric Stationary Phases. Chiral nonracemic chromatographic stationary phases prepared from p-cyclodextrin, derivatized with (R)- and (S)-NEI, and covalently bonded to a silica support are useful for the direct separation of enantiomers of a wide variety of compounds in both normal-phase and reversed-phase HPLC. ... [Pg.453]

Armstrong, DW, W Li, AM Stalcup, HV Secor, RR Izac and J1 Seeman. Capillary gas-chromatographic separation of enantiomers with stable dipentyl-a-, and y-cyclodextrin-derivatized stationary phases. [Pg.262]

Jalkanen T, Tuura J, Makila E, Salonen J (2010) Electro-optical porous silicon gas sensor with enhanced selectivity. Sens Actuators B 147 100-104 Jelinek V, Vrkoslav T, Trojan J, Jindfich JD (2007) Host-guest interactions in gas phase chemical sensing of permethyl-6I-alkenoylamino-6I-deoxy-p-cyclodextrin derivatized porous silicon. Phys Stat Solidi C 4(6) 2083-2087... [Pg.654]

GC using chiral columns coated with derivatized cyclodextrin is the analytical technique most frequently employed for the determination of the enantiomeric ratio of volatile compounds. Food products, as well as flavours and fragrances, are usually very complex matrices, so direct GC analysis of the enantiomeric ratio of certain components is usually difficult. Often, the components of interest are present in trace amounts and problems of peak overlap may occur. The literature reports many examples of the use of multidimensional gas chromatography with a combination of a non-chiral pre-column and a chiral analytical column for this type of analysis. [Pg.218]

Recently, multidimensional GC has been employed in enantioselective analysis by placing a chiral stationary phase such as a cyclodextrin in the second column. Typically, switching valves are used to heart-cut the appropriate portion of the separation from a non-chiral column into a chiral column. Heil et al. used a dual column system consisting of a non-chiral pre-column (30 m X 0.25 mm X 0.38 p.m, PS-268) and a chiral (30 m X 0.32 mm X 0.64 p.m, heptakis(2,3-di-(9-methyl-6-(9-tert-butyldimethylsilyl)-(3-cyclodextrin) (TBDM-CD) analytical column to separate derivatized urinary organic acids that are indicative of metabolic diseases such as short bowel syndrome, phenylketonuria, tyrosinaemia, and others. They used a FID following the pre-column and an ion trap mass-selective detector following the... [Pg.415]

A derivatization with acid chlorides is also possible. Amino acids can be derivatized with 9-fluorenylmethyl chloroformate (FMOC) and separated on a CSP with X-cyclodextrin (ChiraDex gamma ), a cyclic oligosaccharide which consists of eight glucose units. [Pg.199]

Righetti and co-workers [11] were one of the first to demonstrate the utility of classical isoelectric focusing for the chiral separation of small molecules in a slab gel configuration. In their system, dansylated amino acids were resolved enan-tiomerically through complexation with (i-cyclodextrin. Preferential complexation between the cyclodextrin and the derivatized amino acid induced as much as a 0.1 pH unit difference in the pK s of the dansyl group. [Pg.290]

Mourier s report was quickly followed by successful enantiomeric resolutions on stationary phases bearing other types of chiral selectors, including native and deriva-tized cyclodextrins and derivatized polysaccharides. Many chiral compounds of pharmaceutical interest have now been resolved by packed column SFC, including antimalarials, (3-blockers, and antivirals. A summary is provided in Table 12-2. Most of the applications have utilized modified CO, as the eluent. [Pg.303]

Comparisons of LC and SFC have also been performed on naphthylethylcar-bamoylated-(3-cyclodextrin CSPs. These multimodal CSPs can be used in conjunction with normal phase, reversed phase, and polar organic eluents. Discrete sets of chiral compounds tend to be resolved in each of the three mobile phase modes in LC. As demonstrated by Williams et al., separations obtained in each of the different mobile phase modes in LC could be replicated with a simple CO,-methanol eluent in SFC [54]. Separation of tropicamide enantiomers on a Cyclobond I SN CSP with a modified CO, eluent is illustrated in Fig. 12-4. An aqueous-organic mobile phase was required for enantioresolution of the same compound on the Cyclobond I SN CSP in LC. In this case, SFC offered a means of simplifying method development for the derivatized cyclodextrin CSPs. Higher resolution was also achieved in SFC. [Pg.308]

Miniaturized columns have provided a decisive advantage in speed. Uracil, phenol, and benzyl alcohol were separated in 20 seconds by CEC in an 18 mm column with a propyl reversed phase.29 A19 cm electrophoretic channel was etched into a glass wafer, filled with a y-cyclodextrin buffer, and used to resolve chiral amino acids from a meteorite in 4 minutes.30 A 6 cm channel equipped with a syringe pump to automate sample derivatization was used to separate amino acids modified with fluorescein isothiocyanate.31 Nanovials have been used to perform tryptic digests on the 15 nL scale for subsequent separation on capillary Electrophoresis.32 A microcolumn has also been used to generate fractions representing time-points of digestion from a 40 pL sample.33 A disposable nanoelectrospray emitter has been... [Pg.429]

Phenylthiocarbamoyl derivatives of 18 chiral amino acids were separated on a C8 column connected in series to a phenylcarbamoylated (3-cyclodextrin column (Iida et al., 1997). The Cg column separated the derivatized amino acids from one another entering the chiral column. Under this configuration several enantiomers of adjacent amino acids coeluted resulting in poor resolution. However, this configuration was successful in determining the amino acid sequence and chirality of the amino acids in a D-amino acid containing peptide. [Pg.334]

Unfortunately, the relatively low solubility of /8-cyclodextrin has precluded its widespread use as a solubilizing agent. To enhance the solubility of /8-cyclodextrin, much work has been carried out on possible derivatizations of the /8-cyclodextrin skeleton. 2-Hydroxypropyl-/3-cyclodextrin has been found to exhibit the desired enhanced solubility, while still retaining the optimal binding characteristics of underivatized /8-cyclodextrin. In addition, this derivative is relatively nontoxic and may even be used in parenteral applications [63],... [Pg.347]

Recent years have also seen the development of a variety of com-plexation reagents incorporating C-P bonds and their associated functionalities, such as phosphoryl linkages. For example, substituted calixarenes (Figure 1.4) have been developed for extraction of radionuclides, and phosphorus-derivatized cyclodextrins for stereospecific inclusion interactions. [Pg.18]


See other pages where Cyclodextrins derivatized is mentioned: [Pg.265]    [Pg.803]    [Pg.262]    [Pg.138]    [Pg.164]    [Pg.363]    [Pg.140]    [Pg.4886]    [Pg.265]    [Pg.803]    [Pg.262]    [Pg.138]    [Pg.164]    [Pg.363]    [Pg.140]    [Pg.4886]    [Pg.65]    [Pg.218]    [Pg.295]    [Pg.252]    [Pg.459]    [Pg.459]    [Pg.966]    [Pg.13]    [Pg.406]    [Pg.406]    [Pg.305]    [Pg.328]    [Pg.329]    [Pg.333]    [Pg.333]    [Pg.334]    [Pg.174]    [Pg.629]    [Pg.413]    [Pg.128]    [Pg.275]    [Pg.275]    [Pg.276]    [Pg.577]   
See also in sourсe #XX -- [ Pg.1007 ]




SEARCH



Cyclodextrin neutral derivatized

Cyclodextrins derivatization

Cyclodextrins derivatization

© 2024 chempedia.info