Wangfuengkanagul and Chailapakul [9] described the electroanalysis of ( -penicillamine at a boron-doped diamond thin film (BDD) electrode using cyclic voltammetry. The BDD electrode exhibited a well-resolved and irreversible oxidation voltammogram, and provided a linear dynamic range from 0.5 to 10 mM with a detection limit of 25 pM in voltammetric measurement. In addition, penicillamine has been studied by hydrodynamic voltammetry and flow injection analysis with amperometric detection using the BDD electrode. [Pg.134]

The electrochemical behavior of poly(ferrocenylsilanes) has been studied at three levels—in solution by cyclic voltammetry, as films deposited on electrodes, and in the solid state via iodine doping. Solution cyclic voltammetric oxidation and reduction has shown that the polymer, where R/R is Me/Me, reversibly oxidizes in methylene chloride in two stages, apparently with the first oxidation being on alternating iron atoms along the chain.29 Films cast on electrodes behave in a similar way and also show an electrochromic response to oxidation and reduction.30... [Pg.261]

For PPV-imine and PPV-ether the oxidation potential, measured by cyclic voltammetry using Ag/AgCl as a reference are ,M.=0.8 eV and 0.92 eV, respectively. By adopting the values 4.6 eV and 4.8 eV for the work functions of a Ag/AgCl and an 1TO electrode, respectively, one arrives at zero field injection barriers of 0.4 and 0.55 eV. These values represent lower bounds because cyclic voltammetry is carried out in polar solvents in which the stabilization cncigy of radical ions exceeds that in a polymer film, where only electronic polarization takes place. E x values for LPPP and PPPV are not available but in theory they should exceed those of PPV-imine and PPV-ether. [Pg.513]

Fig. 1 shows the cyclic voltammetry of an FePc/XC-72 dispersion, heated at 280°C in an inert atmosphere, in the form a thin porous Teflon bonded coating electrode in a 1 M NaOH solution. A description of the methodology involved in the preparation of this type of electrode may be found in Ref. 3. As can be clearly seen, the voltammetry of this specimen exhibits two sharply defined peaks separated by about 330 mV. The potentials associated with these features are essentially identical to those found by other workers for the reduction and oxidation of films of iron oxy-hydroxide formed on a number of host surfaces, including iron and carbon.(5)... [Pg.258]

When the characteristic time for charge diffusion is lower than the experiment timescale, not all the redox sites in the film can be oxidized/reduced. From experiments performed under these conditions, an apparent diffusion coefficient for charge propagation, 13app> can be obtained. In early work choroamperometry and chronocoulometry were used to measure D pp for both electrostatically [131,225] and covalently bound ]132,133] redox couples. Laviron showed that similar information can be obtained from cyclic voltammetry experiments by recording the peak potential and current as a function of the potential scan rate [134, 135]. Electrochemical impedance spectroscopy (EIS) has also been employed to probe charge transport in polymer and polyelectrolyte-modified electrodes [71, 73,131,136-138]. The methods... [Pg.81]

Electrochemically generated nickei(lll) oxide, deposited onto a nickel plate, is generally useful for the oxidation of alcohols in aqueous alkali [49]. The immersion of nickel in aqueous alkali results in the formation of a surface layer of nickel(ll) oxide which undergoes reversible electrochemical oxidation to form nickel(lll) oxide with a current maximum in cyclic voltammetry at 1.13 V vj. see, observed before the evolution of oxygen occurs [50]. This electrochemical step is fast and oxidation at a prepared oxide film, of an alcohol in solution, is governed by the rate of the chemical reaction between nickel oxide and the substrate [51]. When the film thickness is increased to about 0.1 pm, the oxidation rate of organic species increases to a rate that is fairly indifferent to further increases in the film thickness. This is probably due to an initial increase in the surface area of the electrode [52], In laboratory scale experiments, the nickel oxide electrode layer is prepared by prior electrolysis of nickel sulphate at a nickel anode [53]. It is used in an undivided cell with a stainless steel cathode and an alkaline electrolyte. [Pg.270]

The ferrocenyl dendrimers were electrodeposited in their oxidized forms onto the electrode surfaces (platinum, glassy-caibon, and gold) either by controlled potential electrolysis or by repeated cycling between the appropriate anodic and cathodic potential limits therefore the amount of electroactive material electrode-posited can be controlled with the electrolysis time or the number of scans. The electrochemical behavior of films of the polyfeirocenyl dendrimers was studied by cyclic voltammetry in fresh CH2CI2 and CHjCN solutions containing only supporting electrolyte. [Pg.165]

I11 aprotic solvents, the amalgam of R4N is somewhat stable at temperatures well below 0°C, forming a film on the surface of mercury electrode, and its re-oxidation reaction can be observed by cyclic voltammetry. However, at ambient temperatures or in the presence of water and other protic solvents, the amalgam soon decomposes. [Pg.304]

Polypyrrole thin film doped with glucose oxidase (PPy-GOD) has been prepared on a glassy carbon electrode by the electrochemical polymerization of the pyrrole monomer in the solution of glucose oxidase enzyme in the absence of other supporting electrolytes. The cyclic voltammetry of the PPy-GOD film electrode shows electrochemical activity which is mainly due to the redox reaction of the PPy in the film. Both in situ Raman and in situ UV-visible spectroscopic results also show the formation of the PPy film, which can be oxidized and reduced by the application of the redox potential. A good catalytic response to the glucose and an electrochemical selectivity to some hydrophilic pharmaceutical drugs are seen at the PPy-GOD film electrode. [Pg.139]

The concentration profile of fixed oxidized and reduced sites within the film depends on the dimensionless parameter Dcjr/d2, where r is the experimental timescale, i.e. RT/Fv in cyclic voltammetry, and d is the polymer layer thickness. When Dcix/d2 1, all electroactive sites within the film are in equilibrium with the electrode potential, and the surface-type behavior described previously is observed. In contrast, Dcjx/d2 <3C 1 when the oxidizing scan direction is switched before the reduced sites at the film s outer boundary are completely oxidized. The wave will exhibit distinctive diffusional tailing where these conditions prevail. At intermediate values of Dcjr/d2, an intermediate ip versus v dependence occurs, and a less pronounced diffusional tail appears. [Pg.77]


See other pages where Cyclic voltammetry oxide film electrodes is mentioned: [Pg.37]    [Pg.189]    [Pg.423]    [Pg.320]    [Pg.420]    [Pg.281]    [Pg.37]    [Pg.299]    [Pg.224]    [Pg.146]    [Pg.268]    [Pg.69]    [Pg.108]    [Pg.109]    [Pg.213]    [Pg.70]    [Pg.72]    [Pg.26]    [Pg.332]    [Pg.577]    [Pg.147]    [Pg.154]    [Pg.220]    [Pg.118]    [Pg.502]    [Pg.936]    [Pg.937]    [Pg.186]    [Pg.262]    [Pg.487]    [Pg.413]    [Pg.416]    [Pg.423]    [Pg.1758]    [Pg.86]    [Pg.221]    [Pg.114]    [Pg.145]    [Pg.43]    [Pg.94]    [Pg.173]   
See also in sourсe #XX -- [ Pg.198 , Pg.199 ]




SEARCH



Cyclic oxides

Cyclic voltammetry

Cyclic voltammetry electrode

Film electrodes

Oxidation cyclic

Oxidation cyclic voltammetry

Oxidation electrode

Oxidation films

© 2024 chempedia.info