Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Dc current

Alternating current is converted to direct current (dc) for the smelting cells by siUcon rectifiers. High conversion efficiency (over 99%) and minimum capital costs are achieved when the rectified voltage is 600—900 V dc. Because aluminum smelting cells operate at 4.5—5.0 V, 130 or more cells are coimected in series, forming what the industry calls a potline, which may operate at 50—360 kA. [Pg.99]

A group of computers becomes a network when intercomputer communication is estabhshed. Prior to the 1980s, all system suppliers used proprietaiy protocols to network their systems. Ad hoc approaches were sometimes used to connect third-pai ty equipment, which was not cost-effective in system maintenance, upgrade, and expansion. The recent introduction of standardized protocols has led to a decrease in initial capital cost. Most current DCS network protocol designs are based on the ISO-OSI seven-laver model. [Pg.774]

The electrical power supplied to electrical motors can be from a direct-current (dc) source or an alternating-current (ac) source. Because dc motors are more... [Pg.400]

Railway electric traction systems use either ac or direct current (dc). Third rail systems operate on dc at 600 to 700 V. Overhead systems can be found with either 1,500 or 3,000 V dc, or using ac at a range of voltages (from 11,000 to 50,000) and frequencies (16 2/3 to 60 Hz). The modern standard for overhead catenai y systems is usually 25,000 V and cither 50 nr 60 Hz depending on the industrial standard for the country (50 Hz for most of Europe, 60 Hz for the United States and Japan). [Pg.973]

Direct Current (DC). This current is transmitted for industrial uses only in exceptional situations. The most common sources of direct current are storage batteries and industrial devices called rectifiers, in which alternating current is changed (rectified) to direct current, as is used in electrolytic cells for the manufacture of chlorine gas, magnesium, aluminum, and a few other chemicals. The direct current is flowing from the source through the user application and back to the source, in one direction. The motor is primarily used for speed control of selected equipment. [Pg.625]

A = area of power piston, in. ac = alternating current dc = direct current E = volts... [Pg.686]

The running speed of electric motors, both alternating current (AC) and direct current (DC), varies. Therefore, for monitoring purposes, these motors should be classified as variable-speed machines. A narrowband window should be established to track the true running speed. [Pg.702]

The function that plastics serve in most applications is that of a dielectric or insulator that separates two conductors with an electrical field between them. The field can be a steady direct current (DC) field or an alternating current (AC) field and the frequency range may vary such as from 0 to 1010 Hz. [Pg.222]

This minimal K+ channel (MinK) encoded by KCNEl consists of 130 amino acid residues and has a single transmembrane segment. A slowly activating K+ current-induced MinK cRNA is expressed in Xenopus oocytes. Coexpression of KvLQTl with MinK induced a current that has characteristics similar to cardiac slowly activating delayed-rectifier K+ current, DCS, in contrast to DCR that has relative fast activation and is composed of hERG/MiRPl. [Pg.775]

The ED process is a reliable, membrane-based, electrically driven demineralization technology that is more than 50 years old. It is suitable for the production of basic pure water from lower TDS supply sources. Commercial ED units consist of hundreds of individual cells in a modular membrane sandwich arrangement, bounded by electrodes and linked to a direct current (DC) rectifier-controller. The total treated water flow is a function of the number of cells in the ED unit. [Pg.373]

DC Plasma-Arc Equipment. A typical direct-current (DC) plasma-arc equipment is shown schematically in Fig. [Pg.201]

Fig. 24—Measuring instrument (a) interference lights of the measuring system (b) the scheme of the experiment system. For applying an external voltage to the oil film, one end of direct current (dc) power keeps contacting with the Cr layer on the glass disk, and the other end contacts a shaft welded on the steel ball through an electric brush. The SI02 layer with a thickness of 300 nm has been coated on the surface of the Cr film. Fig. 24—Measuring instrument (a) interference lights of the measuring system (b) the scheme of the experiment system. For applying an external voltage to the oil film, one end of direct current (dc) power keeps contacting with the Cr layer on the glass disk, and the other end contacts a shaft welded on the steel ball through an electric brush. The SI02 layer with a thickness of 300 nm has been coated on the surface of the Cr film.
In addition to microwave plasma, direct current (dc) plasma [19], hot-filament [20], magnetron sputtering [21], and radiofrequency (rf) [22-24] plasmas were utilized for nanocrystalline diamond deposition. Amaratunga et al. [23, 24], using CH4/Ar rf plasma, reported that single-crystal diffraction patterns obtained from nanocrystalline diamond grains all show 111 twinning. [Pg.2]

For controlled-current DC polarography, especially its current density mode, see under Chronopotentiometry at a dme (p. 172). For charge-step polarography, i.e., a controlled charge of coulostatic technique, see ref. 9, pp. 424-429, and ref. 3, pp. 270-276. [Pg.151]

Explain why direct current (dc) rather than alternating current (ac) is used for electrolysis. Why is direct current used in cars ... [Pg.236]

An ESRI system can be built with small modifications of commercial spectrometers by, for example, gradient coils fixed on the poles of the spectrometer magnet, regulated direct current (DC) power supplies, and required computer connections [40,53,55]. Gradients can be applied in the three spatial dimensions, and a spectral dimension can be added by the method of stepped gradients. The spectral dimension is important when the spatial variation of ESR line shapes (as a function of sample depth) is of interest this situation will be described below, in the ESRI studies of heterophasic polymers. In most systems, the software for image reconstruction in ESRI experiments must be developed in-house. [Pg.511]

The IV measurements on molecules and monolayers have been carried out almost exclusively using direct current (DC) frequency-dependent alternating current (AC) impedance measurements have rarely been performed, even though a rich spectroscopy may reveal itself, if the IV measurements were followed as a function of frequency v. [Pg.49]

The conductivity of an ionic conductor can be assessed by direct current (dc) or alternating current (ac) methods. Direct current methods give the resistance R and the capacitance C. The corresponding physical quantity when ac is applied is the impedance, Z, which is the total opposition to the flow of the current. The unit of impedance is the ohm (fl). The impedance is a function of the frequency of the applied current and is sometimes written Z(to) to emphasize this point. Impedance is expressed as a complex quantity ... [Pg.263]


See other pages where Dc current is mentioned: [Pg.2800]    [Pg.102]    [Pg.473]    [Pg.219]    [Pg.396]    [Pg.727]    [Pg.544]    [Pg.177]    [Pg.76]    [Pg.239]    [Pg.85]    [Pg.359]    [Pg.224]    [Pg.7]    [Pg.389]    [Pg.198]    [Pg.56]    [Pg.66]    [Pg.135]    [Pg.251]    [Pg.396]    [Pg.31]    [Pg.371]    [Pg.249]    [Pg.249]    [Pg.250]    [Pg.250]    [Pg.251]    [Pg.251]    [Pg.20]    [Pg.49]   
See also in sourсe #XX -- [ Pg.284 , Pg.399 ]




SEARCH



AC, DC, and Peak Currents

Basic Experiment with DC Current Flow

Current carrying DC plasmas

DC Potentials, No Current Flow

DC and AC Currents

DC current-voltage measurements

DC stray current

DC voltage and current

DC, direct current

Dc current decay

Dc leakage currents

Direct-Current (DC) Measurements

Enhancement of Anodic Corrosion by Cell Formation or Stray Currents from dc Installations

Stray Currents from High-Voltage dc Power Lines

Stray Currents from dc Railways

Understanding the AC, DC and Peak Currents

© 2024 chempedia.info