Cooling machines

For large motors, which use water as the secondary coolant in a closed circuit, the temperature of the cooling air, i.e. of the primary coolant, varies with the temperature of the cooling water inlet temperature and its rate of flow. For the performance of the motor output, this primary coolant, temperature has the same significance as the ambient temperature for an air-cooled motor. The motor output is unaffected by the ambient temperature. For such motors the output graph is shown in Figure 1.13 at different coolant temperatures and altitudes. The rating at 25°C inlet water temperature for water-cooled machines is the same as for air-cooled machines at an ambient temperature of 40°C. [Pg.16]

A totally enclosed fan-cooled machine is a frame-surface cooled totally enclosed machine equipped for self-exterior cooling by means of a fan or fans integral with the machine but external to the enclosing parts. [Pg.649]

A totally-enclosed water-cooled machine is a totally enclosed machine which is cooled by circulating water, the water or water conductors coming in direct contact with the machine parts. [Pg.649]

A totally enclosed air-to-water-cooled machine is a totally enclosed machine which is cooled by circulating air which, in turn, is cooled by circulating water. It is provided with a water-cooled heat exchanger, integral (IC7 W) or machine mounted (IC8 W), for cooling the internal air and a fan or fans, integral with the rotor shaft (IC 1W) or separate (IC 5W) for circulating the internal air. [Pg.649]

A totally enclosed air-over machine is a totally enclosed frame-surface cooled machine intended for exterior cooling by a ventilating means external to the machine. [Pg.649]

Load factor is particularly important with air-cooled machines where sustained full-load operation results in an early build-up of deposits on valves and other parts. This build-up increases the frequency of maintenance required to maintain compressor reliability. Intermittent operation is always recommended for these units. The frequency and duration of unloaded operation depends on the type, size, operating pressure of the compressor. Air-cooled compressors for higher than 200-psig-pressure application are usually rated by a rule that states that the compressing time shall not exceed 30 minutes or less than 10 minutes. Shutdown or unloaded time should be at least equal to compression time or 50 per cent. [Pg.637]

The plant location can determine the mechanical construction - for example, in case earthquake factors are to be considered, and climatic conditions can have an impact on machinery sizing and dimensions particular for cooling machines and electrical drives. [Pg.383]

In this process two refrigeration machines are employed for sensible cooling. Machine Rs provides the supplementary cooling of the incoming saline water necessitated by the difference between the specific heats of ice and saline water, and machine provides the supplementary cooling necessitated by the temperature differential, tx. [Pg.70]

Bioletti, F.T. A New Wine-Cooling Machine, Calif., Agric. Exp. Stn. Bull. [Pg.28]

Meltser, L. H., "Method of Thermodynamic Evaluation of Theoretical and Actual Cycles of Cooling Machines,"... [Pg.427]

I - computer, 2 - condenser, 3 - exhaust system, 4 - vacuometer, 5 - manometer, 6 - thermal controlled box, 7 - thermostated liquid loop, 8 - cooling machine, 9 - power supply, 10 - wattmeter,... [Pg.403]

Coefficient of performance CoP Ratio of energy of solar origin Es delivered by the system as useful heat (excluding Eg) to the parasitic energy used CoP = Es/Ep (this definition differs somewhat from that used for cooling machines or heat pumps). [Pg.219]

Their name comes from the fact that air from the atmosphere is taken through the system and discharged to the rooms (so there is no closed circulation of some refrigerant, as in cooling machines). All variants rely on evaporative cooling and the removal of moisture by some sorbent material (desiccant), which will then be reactivated by... [Pg.229]

Lead bullion is frq)ped to the continuous drossing furnace (CDF). The purpose of the CDF is to precipitate copper into matte by cooling the bullion. Recirculating the lead through a cooling machine cools the bullion. The freeboard temperature is maintained at 1280-1320°C by three natural gas burners. A matte layer is maintained in the furnace to insulate the slag from the cold lead. Sulphur is added to the return pot to prevent the formation of speiss. The temperature of the lead is reduced to 37S°C. [Pg.176]

IO3. A wedge-shaped fin is used to cool machine-gun barrels. The fin has a triangular cross section and is L meters high (from tip to base) and W meters wide at the base. This longitudinal fin is i meters long. It loses heat through a constant heat transfer coefficient h to ambient air at temperature 7. The flat base of the fin sustains a temperature Th- Show that the temperature variation obeys... [Pg.144]

Here, we describe equilibrium methods (slow cooling) for both rats and mice. These methods use a programmable cooling machine embryos are exposed to moderate cryoprotectant concentrations and are cooled slowly at 0.3-2°C/min. Embryos are dehydrated during this slow-cooling process. [Pg.105]

The generator is a high-efficiency, hydrogen-cooled machine arranged to supply AC at medium voltage to the electric power system. [Pg.156]

Besides the desired plant capacity, raw material and product specification are also necessary to get knowledge of local conditions like climate, altitude, and earthquake factor in order to design adequate building and service units, especially cooling machines and electrical drives. [Pg.177]

With the exception of copper-containing alloys of the 2000 and 7000 series, aluminium and aluminium alloys are very widely used in the storage and transport of gaseous or liquid ammonia, in cooling machines (heat exchangers, etc.) as well as in production plants for ammonia and nitric acid. The ASME Boiler and ftessure Code as well as the German Code AD Merkblatt W/6/1 permit the use of aluminium equipment up to 200 °C. [Pg.390]

A schematic of a Pomeranchuk cooling machine proposed by Satoh is shown in Fig. 4.37. A major problem in the operation of such cooling devices on a large scale is the method of precooling He. In Satoh s device, two Leiden dilution refrigerators (LDR) use " He to precool the He. After cooling the liquid below 300 mK the liquid He is sealed into the compressor cell and the bellows are used to mechanically and adiabatically compress the cell. [Pg.169]

Synthesis of 13 A flask was charged with MacMillan catalyst (2/ , 57 )-5-benzyl-2-icri-butyl-3-methyhmidazolidin-4-one 12 (23 mg, 0.093 mmol) and then trifluoroacetic acid (TEA) (5% v/v in CH2CI2, 0.14 mL, 0.093 mmol) was introduced via a syringe. The flask was flushed with argon and cooled to —75°C (cooling machine). The mixture was stirred for 5 minutes, and then aldehyde 11 (0.2778 g, 1.394 mmol) in CH2CI2 (0.66 mL) and t-PrOH (O.lSmL) was... [Pg.808]

Thermal separation by retracting the cooled machine nozzle from the heated mould. [Pg.124]