Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Conversion thermal conductivity

Electrical—Thermal Conductivities. Electrical conductivities of alloys (Table 5) are often expressed as a percentage relative to an International Annealed Copper Standard (lACS), ie, units of % lACS, where the value of 100 % lACS is assigned to pure copper having a measured resistivity value of 0.017241 Q mm /m. The measurement of resistivity and its conversion to % lACS is covered under ASTM B193 (8). [Pg.222]

Determination of oxygen. The sample is weighed into a silver container which has been solvent-washed, dried at 400 °C and kept in a closed container to avoid oxidation. It is dropped into a reactor heated at 1060 °C, quantitative conversion of oxygen to carbon monoxide being achieved by a layer of nickel-coated carbon (see Note). The pyrolysis gases then flow into the chromatographic column (1 m long) of molecular sieves (5 x 10-8 cm) heated at 100 °C the CO is separated from N2, CH4, and H2, and is measured by a thermal conductivity detector. [Pg.248]

The catal5fsts were tested for CO oxidation in a flow reactor using a 2.5 % CO in dry air mixture at a fixed flow rate of 200 seem. Thirty milligrams of the catalyst were used for each experimental run. The reaction was conducted at 298, 323, 373 and 473 K with 75 minutes duration at each temperature. The carbon monoxide conversion to carbon dioxide was monitored by an online gas chromatogr h equipped with a CTR-1 column and a thermal conductivity... [Pg.413]

C30 oil, homopolymer of 1-decene, Ethyl Corp., Inc.) served as the start-up solvent for the experiments. The catalyst (ca. 5-8 g) was added to start-up solvent (ca. 300 g) in the CSTR. The reactor temperature was then raised to 270°C at a rate of l°C/min. The catalyst was activated using CO at a space velocity of 3.0 sl/h/g Fe at 270°C and 175 psig for 24 h. FTS was then started by adding synthesis gas mixture (H2 CO ratio of 0.7) to the reactor at a space velocity of either 3.1 or 5.0 sl/h/g Fe. The conversions of CO and H2 were obtained by gas chromatography (GC) analysis (HP Quad Series Micro-GC equipped with thermal conductivity detectors) of the product gas mixture. The reaction products were collected in three traps maintained at different temperatures—a hot trap (200°C), a warm trap (100°C), and a cold trap (0°C). The products were separated into different fractions (rewax, wax, oil, and aqueous) for quantification by GC analysis. However, the oil and the wax (liquid at room temperature) fractions were mixed prior to GC analysis. [Pg.122]

In a typical pulse experiment, a pulse of known size, shape and composition is introduced to a reactor, preferably one with a simple flow pattern, either plug flow or well mixed. The response to the perturbation is then measured behind the reactor. A thermal conductivity detector can be used to compare the shape of the peaks before and after the reactor. This is usually done in the case of non-reacting systems, and moment analysis of the response curve can give information on diffusivities, mass transfer coefficients and adsorption constants. The typical pulse experiment in a reacting system traditionally uses GC analysis by leading the effluent from the reactor directly into a gas chromatographic column. This method yields conversions and selectivities for the total pulse, the time coordinate is lost. [Pg.240]

Catalysts were tested for oxidations of carbon monoxide and toluene. The tests were carried out in a differential reactor shown in Fig. 12.7-1 and analyzed by an online gas chromatograph (HP 6890) equipped with thermal conductivity and flame ionization detectors. Gases including dry air and carbon monoxide were feed to the reactor by mass flow controllers, while the liquid reactant, toluene was delivered by a syringe pump. Thermocouple was used to monitor the catalyst temperature. Catalyst screening and optimization identified the best catalyst formulation with a conversion rate for carbon monoxide and toluene at room temperature of 1 and 0.25 mmolc g min1. Carbon monoxide and water were the only products of the reactions. [Pg.376]

Vermiculites are formed by the decomposition of mica. They contain layers of water and magnesium ions in place the potassium ions. When heated to 800°C-1100°C, vermiculite expands because of the conversion of the water to gas. The expanded vermiculite has a low thermal conductivity and density, and is used as a thermal and sound barrier as well as an aggregate in lightweight concrete. It is also used as a moisture-retaining soil conditioner in planting. [Pg.389]

Edit and others "The Condensed Chemical Dictionary , Re inhold, NY (1961), p 246 (Chain reactions) 28)E.Teli, JChemPhys 36, 901-03 (1962) (On the speed of reaction at high pressure) 29)Encycl of Expls, PATR 2700, Vol 2(1962), p C146-L (chain reactions) 30)Yu.N.Denisov Ya.K.Troshin, "On the Mechanism of Detonative Combustion , 8th SympCombstn (1962), pp 600-10 31)A.M.Gri shin D-M.Todes, DoklAkad N 151 (2), 366-68 (1963) CA 59, 12585 (1963) (Thermal expln with heat transfer by conversion and conduction)... [Pg.315]


See other pages where Conversion thermal conductivity is mentioned: [Pg.6]    [Pg.8]    [Pg.130]    [Pg.378]    [Pg.436]    [Pg.508]    [Pg.508]    [Pg.432]    [Pg.558]    [Pg.145]    [Pg.1000]    [Pg.88]    [Pg.88]    [Pg.117]    [Pg.248]    [Pg.206]    [Pg.150]    [Pg.880]    [Pg.444]    [Pg.520]    [Pg.51]    [Pg.5]    [Pg.545]    [Pg.117]    [Pg.370]    [Pg.78]    [Pg.36]    [Pg.58]    [Pg.244]    [Pg.243]    [Pg.243]    [Pg.78]    [Pg.342]    [Pg.423]    [Pg.69]    [Pg.472]    [Pg.89]    [Pg.508]    [Pg.508]   
See also in sourсe #XX -- [ Pg.945 ]

See also in sourсe #XX -- [ Pg.945 ]




SEARCH



Conversion Factors for Thermal Conductivity Units

Thermal conductivity conversion factors

Thermal conductivity, conversion table

Thermal conversion

© 2024 chempedia.info