From the calibration point of view, manometers can be divided into two groups. The first, fluid manometers, are fundamental instruments, where the indication of the measured quantity is based on a simple physical factor the hydrostatic pressure of a fluid column. In principle, such instruments do not require calibration. In practice they do, due to contamination of the manometer itself or the manometer fluid and different modifications from the basic principle, like the tilting of the manometer tube, which cause errors in the measurement result. The stability of high-quality fluid manometers is very good, and they tend to maintain their metrological properties for a long period. [Pg.1151]

Consider again a batch polymerization process where the process is characterized by the sequential execution of a number of steps that take place in the two reactors. These are steps such as initial reactor charge, titration, reaction initiation, polymerization, and transfer. Because much of the critical product quality information is available only at the end of a batch cycle, the data interpretation system has been designed for diagnosis at the end of a cycle. At the end of a particular run, the data are analyzed and the identification of any problems is translated into corrective actions that are implemented for the next cycle. The interpretations of interest include root causes having to do with process problems (e.g., contamination or transfer problems), equipment malfunctions (e.g., valve problems or instrument failures), and step execution problems (e.g., titration too fast or too much catalyst added). The output dimension of the process is large with more than 300 possible root causes. Additional detail on the diagnostic system can be found in Sravana (1994). [Pg.91]

Modem instrumentation has improved substantially in recent years, which has enabled the measurement of XPS spectra of superior resolution necessary to reveal the small BE shifts present in highly covalent compounds such as those studied here. In a laboratory-based photoelectron spectrometer, a radiation source generates photons that bombard the sample, ejecting photoelectrons from the surface that are transported within a vacuum chamber to a detector (Fig. 2). The vacuum chamber is required to minimize the loss of electrons by absorption in air and, if a very high quality vacuum environment is provided (as is the case with modem instruments), the surface contamination is minimized so that the properties of the bulk material are more readily determined. [Pg.95]

The analysis of tetramethylammonium hydroxide (TMAH) solutions manufactured by SACHEM Inc. of Cleburne, Texas, includes the determination of trace elements. These elements cause less-than-optimum performance of integrated circuit boards manufactured by SACHEM s customers that use these solutions in their processes. Alkali and alkaline earth metals (e.g., Li, Na, K, Mg, Ca, and Ba) can reduce the oxide breakdown voltage of the devices. In addition, transition and heavy metal elements (e.g., Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ag, Au, and Pb) can produce higher dark current. Doping elements (e.g., B, Al, Si, P, As, and Sn) can alter the operating characteristics of the devices. In SACHEM s quality control laboratory, ICP coupled to mass spectrometry is used to simultaneously analyze multiple trace elements in one sample in just 1 to 4 min. This ICP-MS instrument is a state-of-the-art instrument that can provide high throughput and low detection Emits at the parts per thousand level. Trace elemental determination at the parts per thousand level must be performed in a clean room so that trace elemental contamination from airborne particles can be minimized. [Pg.292]

Installation and operational qualification work includes verification of temperature, pressure, and flow rates, instrument calibration, and thorough flushing of the entire system to remove oil, metal particles, and other contaminants. The type of testing and acceptance limits listed in the validation protocol may vary from firm to firm however, compressed air with product contact should be tested for such quality attributes as hydrocarbons, water vapor, and microbial content (typically less than 0.1 CFU/cu. ft.)... [Pg.184]

Further enhancements in instrumental sensitivity will depend on concurrent improvements in the quality of HPLC grade solvents and the ability to maintain a contaminant-free laboratory environment. [Pg.260]

The Food Standards Code [10] is the main regulatory instrument which controls the quality of food, contaminant levels, approved additives, processing aids, sanitisers and disinfectants and these standards are performance based. If a chemical or a group of chemicals is covered by a food standard then they must only be used in food in accordance with the standard. However, if a chemical is not mentioned in a standard, then this does not preclude its use in food. For a new chemical not previously used in food production, it would be necessary for the supplier to undertake a detailed risk analysis of the product to demonstrate its safety and suitability. The assessment would need to consider both the toxicological profile of the chemical and the levels of human exposure that are likely to arise from residues in food. [Pg.276]

Specification tests are perfomied on plant streams once or twice per worker shift, or even more often if necessary, to assure the continuing quality of the product. The tests are also performed on a sample from an outgoing shipment, and a sample of the shipment is usually retained for checking on possible subsequent contamination. Tests on specialty types of acetone may require sophisticated instruments, eg, mass spectrometry for isotopically labeled acetone. [Pg.98]

Particle Sizing Systems (PSS) is a designer and manufacturer of particle sizing instruments that are used for research and development, USP quality assurance, contamination and in-line monitoring. [Pg.486]


See other pages where Contamination instrument quality is mentioned: [Pg.224]    [Pg.92]    [Pg.370]    [Pg.100]    [Pg.542]    [Pg.225]    [Pg.486]    [Pg.259]    [Pg.373]    [Pg.524]    [Pg.131]    [Pg.6]    [Pg.224]    [Pg.326]    [Pg.14]    [Pg.272]    [Pg.326]    [Pg.197]    [Pg.234]    [Pg.203]    [Pg.366]    [Pg.130]    [Pg.228]    [Pg.259]    [Pg.131]    [Pg.137]    [Pg.131]    [Pg.58]    [Pg.392]    [Pg.275]    [Pg.136]    [Pg.184]    [Pg.110]    [Pg.661]    [Pg.478]    [Pg.12]    [Pg.135]    [Pg.8]    [Pg.199]    [Pg.212]    [Pg.25]   