Solvents HPLC-grade

The pump is a very delicate and sensitive part of HPLC unit therefore, all buffer solutions should be removed carefully after use either by pumping water (HPLC-grade) or an appropriate solvent (HPLC-grade) for several minutes. [Pg.457]

A Waters Sci. Ltd, GPC/LC Model 150C with Waters Model 130 Data Module was used. The instrument was operated at 135°C with TCB as a solvent (HPLC grade from Fisher Sci., filtered through 0.5 um filter with silicagel). Four and five u-Styragel (Waters Sci. Inc.) columns with pore sizes (500), 10, 10, 10, ... [Pg.98]

Fig. 1. Ultraviolet absorption of solvents (HPLC grade unless otherwise stated). A, acetonitrile (far-UV grade) B, methyl tert-butyl ether C, acetonitrile D, 1-chlorobutane E, methylene chloride F, acetic acid (AR grade) G, ethyl acetate H, acetone I, hexane J, iso-octane K, methanol L, tetrahydro-furan M, chloroform N, diethylamine (ARgrade). Fig. 1. Ultraviolet absorption of solvents (HPLC grade unless otherwise stated). A, acetonitrile (far-UV grade) B, methyl tert-butyl ether C, acetonitrile D, 1-chlorobutane E, methylene chloride F, acetic acid (AR grade) G, ethyl acetate H, acetone I, hexane J, iso-octane K, methanol L, tetrahydro-furan M, chloroform N, diethylamine (ARgrade).
The concentration of organic modifier in the eluent is the predominant factor that governs the retention of analytes in RPLC. Highly purified solvents (HPLC grade) are recommended in order to minimize contamination of the stationary phase with impurities of the solvents and reduction of the background absorbance if they contain impurities that have UV chromophores >190 nm. [Pg.145]

Solvents HPLC-grade methanol and analytical-grade acetic acid were distilled before use. Water used for HPLC was glass-distilled deionized water passed through a high-purity organic remover. [Pg.337]

Suitable solvent systems for MNA were identified for the solutiorvbased all-optical switching device. Dlmethylformamide (DMF), p-dioxane, propylene carbonate (PC) and tetrahydrofuran (THF) provided high solubility with a wide range of index choices. Solubility of MNA in each solvent (HPLC grade) at room temperature was measured for the determination of the range of refractive index available (Table 1). [Pg.583]

Chemicals and Solvents. HPLC grade acetonitrile (Fisher Scientific Co.) was the solvent... [Pg.138]

The density of the powder samples was determined by a simple displacement technique. Narrow bore graduated cylinders were used as volumenometers. A known volume of non-solvent (HPLC grade methanol for polyelectrolytes) was added to the... [Pg.234]

Sodium sulfate, anhydrous, ACS grade (Fisher Scientific) or equivalent Solvents acetonitrile (ACN), acetone, dichloromethane (DCM), methanol (MeOH) and water (pesticide or HPLC grade)... [Pg.1235]

All solvents were of HPLC grade and were used as received, except for tetrahydrofuran (THF) which was freshly distilled from sodium and benzophenone prior to use. [Pg.156]

Many reagent grade solvents contain levels of impurities that make them unsuitable for long term use in hplc. Sometimes the impurities are added deliberately as antioxidants, stabilisers, or for denaturing. Wherever possible, hplc grade solvents should be used to prepare mobile phases, or alternatively the solvents should be adequately purified before use. [Pg.191]

High-performance liquid chromatography (HPLC) grade Solvents of suitable purity for use in liquid chromatography procedures. [Pg.31]

If the mobile phase contains liquids that are not certified as HPLC grade solvents, they must be filtered ahead of time as well as degassed. The reason is that the packed bed of finely divided stationary phase particles through which the mobile phase percolates is itself an excellent filter. Particles in the mobile phase as small as 0.5 jim in diameter can be filtered out. The result of this is a decreased effectiveness of the column with time and possibly a blocked flow path. Unfiltered samples also may contain particles and cause this problem. [Pg.370]

Always use only HPLC-Grade solvents for better precision and reproducibility of results. [Pg.463]

Use HPLC grade solvent use freshly prepared eluent Fill with the same eluent Adjust zero balance... [Pg.28]

The mobile phases used to provide separations that interface cleanly with the MS are of great importance. Both isocratic and gradient elution can be used. High purity (HPLC grade) water, acetonitrile, and Ci to C4 alcohols are compatible with APTelectrospray and APCI. Less polar solvents such as hexane, cyclohexane, toluene, and ethyl acetate are also compatible with APCI. In general, it is advisable to always have an organic solvent present in the mobile phase to reduce surface tension, which enhances the formation of smaller, more uniform droplets and also aids vaporization and ionization and hence provides greater sensitivity. [Pg.161]

Always use HPLC-grade solvents. Always filter and degas aqueous mobile phase. [Pg.263]

The test procedure can be performed by pumping HPLC grade water at a specified flow rate under a controlled back-pressure, using a commercial back-pressure device connected in-line just after the pump. A f 000 psi back-pressure device is recommended. It is also advised that about f % MeOH be added to the water in order to minimize biological growth. While timing the process with a calibrated stop watch, the pump effluent should then be collected in a volumetric flask. From this, one can calculate the actual solvent flow at each flow rate. [Pg.315]

Materials. Aldicarb standards were obtained from the United States Environmental Protection Agency (USEPA), Quality Assurance Section and from Union Carbide Corporation. Crystalline samples of carbofuran and 3-hydroxycarbofuran were supplied by the Agricultural Chemical Group of FMC Corporation. Reference standards of methomyl (99% pure) and oxamyl (99% pure) were obtained from USEPA. HPLC grade methanol was purchased from Burdick and Jackson, Inc. Methylene chloride used for bulk extractions of the carbamate pesticides in solution was recovered, distilled and reused. Analytical reagent grade chemicals and solvents were used in all experiments. Doubly distilled deionized water was used for solution rate studies. Deionized distilled water (DDW) was used for dilutions in reactive ion exchange experim ts., , ... [Pg.247]

Typically, two solvents are prepared that are mixed in a controlled manner by the pumping system according to a preset gradient. The content of the organic modifier is increased linearly, stepwise, or exponentially in order to displace the sample. There is, therefore, the need for two solvent systems referred to as A (which is the aqueous component) and B (which contains the organic modifier HPLC grade, UV transparent). [Pg.639]

The baseline noise as offered by many UV-Vis detectors is in the range 1 to 2 x 10 5 AU and much lower than the limit of detection and quantitation required for most applications. This value is achieved under optimum conditions, such as with a reasonably new lamp, an ultraclean flow cell, stable ambient temperature, HPLC-grade solvents, and no microleaks in the entire HPLC system. These conditions are always valid at the manufacturer s final test and probably at the time of installation in the user s laboratory. However, after some time, optical and mechanical parts deteriorate (e.g., the lamp loses intensity and the flow cell may become contaminated). If we repeat the test after 3, 6, or 12 months, the noise of 1 x 10 5 AU may no longer be obtained. The recommendation is to select acceptance criteria according to the intended use of the system. [Pg.272]

All used solvents and chemicals are of HPLC grade or of known analytical purity. [Pg.644]


See other pages where Solvents HPLC-grade is mentioned: [Pg.142]    [Pg.506]    [Pg.180]    [Pg.155]    [Pg.142]    [Pg.506]    [Pg.180]    [Pg.155]    [Pg.219]    [Pg.125]    [Pg.1148]    [Pg.1321]    [Pg.152]    [Pg.87]    [Pg.101]    [Pg.54]    [Pg.520]    [Pg.214]    [Pg.39]    [Pg.42]    [Pg.253]    [Pg.23]    [Pg.258]    [Pg.319]    [Pg.303]    [Pg.99]    [Pg.232]    [Pg.246]    [Pg.212]    [Pg.227]    [Pg.646]    [Pg.254]   