Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Confinement of column

Continuous porous polymer rods have been prepared by an in situ polymerization within the confines of a chromatographic column. The column is filled with glycidyl methacrylate and ethylene dimethacrylate monomer mixtures, cyclo-hexanol and dodecanol diluents, and AIBN initiator. They are then purged with nitrogen, stopped, and closed with a silicon rubber septum. The polymerization is allowed to proceed for 6 hr at 70°C with the column acting as a mold (47). [Pg.14]

Several research groups used another interesting column technology as an alternative to the modification of the capillary surface. This method is inherited from the field of electrophoresis of nucleic acids and involves capillaries filled with solutions of linear polymers. In contrast to the monolithic columns that will be discussed later in this review, the preparation of these pseudostationary phases need not be performed within the confines of the capillary. These materials, typically specifically designed copolymers [85-88] and modified den-drimers [89], exist as physically entangled polymer chains that effectively resemble highly swollen, chemically crosslinked gels. [Pg.25]

There are many facets of this study which we feel merit further investigation. In particular it is necessary to consider am extension of the proposed model, which in its present form is confined to the performance of a simple column, to cover the behaviour of any set of columns since it is column sets which are normally used. In addition, it is important to consider the input to the model which should be truly representative of polymers with a molecular weight distribution and not merely a concentration pulse of perfectly monodisperse polymer. In relation to this latter suggestion it would be significant if it were possible to link this model to the very real problem of deconvolution, i.e. the removal of instrumental and column broadening from the observed chromatogram to produce the true molecular weight distri-... [Pg.42]

In situ (Latin for in the place ) polymerization means the fabrication of a polymer network directly in the finally desired shape and geometry. In the context of monolithic separation columns, the term in situ is referred to the polymerization in the confines of a HPLC column or a capillary as mold. [Pg.12]

Previous correlations of the influence of z on terminal velocities (El, H4, Ml, SI, S6, T3, Ul) are limited to specific systems, fail to recognize the different regimes of fluid particles (see Chapter 2), or are difficult to apply. In the present section we consider both bubbles and drops, but confine our attention to those of intermediate size (see Chapter 7) where Eo < 40 and Re > 1. Only the data of Uno and Kintner (Ul), Strom and Kintner (S6) and Salami et ai (SI) are used since other workers either failed to use a range of column sizes for the same fluid-fluid systems, or it was impossible to obtain accurate values of the original data. This effectively limits the Reynolds number range to Re > 10 for the low M systems studied. [Pg.233]

In the case of mining expls, it provides a measure of probable borehole performance, ie, whether or not the expl may be depended upon to propagate in a long column under the confinement of the borehole (See also Detonation by Influence)... [Pg.139]

It appears that with a proper choice of confining gas and of column width, "spin can be induced at will... [Pg.560]

C-L. Scott, The Sensitivity of Selected Conventional and Heat Resistant Explosives at Low Temperatures", NOLTR 70—36 (1970), reviewed by G. Cohn, Edit in Expls- Pyrots 4(6), 1971 (The effects of temp, confinement, and column diam on the shock... [Pg.336]

The effectiveness of one chge in initiating another is determined by the props of the expl, its loading density, and the dimensions confinement of the chge. The effective output of a donor charge increases systematically with its diameter. The optimum diameter of an acceptor, from the point of view of the air gap across which it can be initiated, is slightly less than the diam of the donor, especially for well confined columns of expls... [Pg.364]

Alternatives to batch testing include the use of diffusion cells or flowthrough columns. Diffusion cells are easier to operate, but are less representative of field conditions where some advection may occur. However, operation of columns at very low flow rates is difficult and subject to artifacts. To minimize possible wall effects associated with shrink/swell behavior of low-permeability clay materials, several researchers have utilized column devices that provide a confining pressure, such as flexible wall permeameters (e.g., Acar and Haider, 1990 Smith and Jaffe, 1994 Shackelford and Redmond, 1995 Khandelwal et al., 1998 Khandelwal and Rabideau, 2000). [Pg.120]

Early in the development of capillary electrophoresis, it was noted that the successful detection of separated sample components present within the narrow confines of these capillary tubes posed a major challenge (2)- In response to this challenge, much research has been directed toward the development of sensitive and selective detectors for capillary electrophoresis. CE detector technology has been largely borrowed from the field of high-performance liquid chromatography (HPLC), especially from micro-column HPLC. [Pg.61]

Originally, CEC employed the same type of columns as pHPLC, namely, conventional HPLC silica-based particles packed into fused silica capillaries. Porous plugs attached to the fused silica walls—frits—hold the sorbent material within the confines of the capillary tubing. Just as in pHPLC, frit fragility significantly decreases the lifetime of the column. Moreover, nonspecific interactions... [Pg.357]

In this review we examine improvements in column techniques, development of new separation media, and new applications of interest to the clinical chemist and biochemist. As a consequence of the wide nature of column chromatography, we have necessarily had to limit ourselves to fields where most progress has been made over the last few years. Thus we have confined ourselves mainly to affinity chromatography, gel chromatography, and high pressure liquid chromatography. [Pg.106]

One-step method for the preparation of highly enantioselective monolithic columns for CEC has been developed by Frechet et al. The chiral polymer bed of defined pore distribution and chiral ligand concentration has been synthesized within the confines of untreated fused silica capillaries using a mixture of O-[2-(methacryloyloxy)ethylcarbamoyl]-10,ll-dihydroquinidine 76, ethylene dimethacrylate (EDMA), and glycidyl methacrylate or 2-hydroxyethyl methacrylate (HEMA) in the mixture of cyclohexanol and 1-dodecanol as porogenic solvents. Under optimized synthetic and chromatographic conditions, these materials with the desired characteristics were demonstrated to efficiently separate a model racemic DNZ-Leu, Figure 13.24 [146],... [Pg.461]


See other pages where Confinement of column is mentioned: [Pg.668]    [Pg.247]    [Pg.85]    [Pg.85]    [Pg.602]    [Pg.2315]    [Pg.668]    [Pg.247]    [Pg.85]    [Pg.85]    [Pg.602]    [Pg.2315]    [Pg.14]    [Pg.14]    [Pg.860]    [Pg.27]    [Pg.58]    [Pg.392]    [Pg.197]    [Pg.398]    [Pg.482]    [Pg.284]    [Pg.216]    [Pg.207]    [Pg.346]    [Pg.698]    [Pg.198]    [Pg.201]    [Pg.230]    [Pg.379]    [Pg.482]    [Pg.49]    [Pg.336]    [Pg.861]    [Pg.436]    [Pg.148]    [Pg.1483]    [Pg.177]   
See also in sourсe #XX -- [ Pg.85 ]




SEARCH



© 2024 chempedia.info