Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Volume cones

Any pyramid or cone volume = 1/3 Bh where B = area of base... [Pg.15]

Although previous studies showed that direct ionization from the outlet separation channel at the chip surface with Taylor cone formation could be possible, this is probably not optimal because the ESI cone volumes are larger than peak volumes. With short... [Pg.497]

The effort at precision was pushed further as mathematicians worked from the cone-volume principle to specify the volume of saleable wood contained by a standardized tree (Normalbaum) of a given... [Pg.14]

The relationship of a standard cone volume and the explosive mass to is in Eq. 2.45. [Pg.55]

Tumblers, double cone Volume, V, ft 50-270 ft Cp = 2,700 Carbon steel... [Pg.554]

Left 1-photon irradiation, showing the double-cone volume of irradiated tissue. [Pg.258]

The systems of such type have been developed of all last 10 years. We shall bring some characteristics of one of the last development within the framework of European BRITE project, carried out in LETT This 3D cone-beam tomograph is referred to as EVA Bench or Equipment for Voludensimetry Analysis. It is oriented on NDT of industrial products from ceramics and other composites. One of the main task of this tomograph is achievement of high resolution at study of whole internal volume of researched object. For test sample of the size 10mm spatial resolution in 50mm was obtained [14]. [Pg.217]

The section cd can be regarded as due to relatively large cone-shaped pores that would fill and empty without hysteresis. At the end of section cd, then, all pores should be filled, and the adsorbent should hold the same volume of any adsorbate. See Ref. 200 for a discussion of this conclusion, sometimes known as the Gurvitsch rule. [Pg.666]

The distillation heads Fig. 22(F) and Fig. 22(G) can be fitted with thermometers having a ground-glass cone just above the bulb (Fig. 22(M)). These are expensive, and it is usually more convenient to fit a thermometer pocket (Fig. 22(N)) which consists of a small well , fitting as shown into the neck of the flask. A small volume of mercury is placed in the well just to cover the bulb of a conventional thermometer, and thus provides excellent thermal contact between the thermometer and the sides of the pocket. [Pg.44]

Ltebermann Reaction To 1 minute crystal of sodium nitrite in a clean dry test-tube add 0 5 g. of phenol and heat very gently for about 20 seconds allow to cool and add twice the volume of cone. H2S04. On rotating the tube slowly in order to mix the contents, a deep green or deep blue coloration develops (some times only after i 2 minutes). Dilute cautiously with water the solution turns red. Now add an excess of NaOH solution the green or blue coloration reappears. [Pg.340]

Carbon—carbon composites for rocket nozzles or exit cones are usually made by weaving a 3D preform composed of radial, axial, and circumferential carbon or graphite fibers to near net shape, followed by densification to high densities. Because of the high relative volume cost of the process, looms have been designed for semiautomatic fabrication of parts, taking advantage of selective reinforcement placement for optimum thermal performance. [Pg.5]

Hollow Sprays. Most atomizers that impart swid to the Hquid tend to produce a cone-shaped hoUow spray. Although swid atomizers can produce varying degrees of hoUowness in the spray pattern, they aU seem to exhibit similar spray dynamic features. For example, detailed measurements made with simplex, duplex, dual-orifice, and pure airblast atomizers show similar dynamic stmctures in radial distributions of mean droplet diameter, velocity, and Hquid volume flux. Extensive studies have been made (30,31) on the spray dynamics associated with pressure swid atomizers. Based on these studies, some common features were observed. Test results obtained from a pressure swid atomizer spray could be used to iUustrate typical dynamic stmctures in hoUow sprays. The measurements were made using a phase Doppler spray analyzer. [Pg.331]

Media-Particle Size The size of the media particle is important. A relatively coarse medium (minus 100 mesh) is commonly used in larger-volume static-type separators such as cones. However, in dynamic sep-... [Pg.1789]

The submitters purchased 2-chloro-2-methylbutane from Eastman Kodak Company. The checkers prepared the halide as follows. A separatory funnel was charged with 21.5 mL (0.2 mol) of 2-methyl-2-butanol and IQO mL of coned hydrochloric acid. The mixture was shaken vigorously with periodic venting for 10 min. The layers were separated and the 2-chloro-2-methylbutane layer (upper) was washed several times with equal volumes of cold water. The product was dried over calcium chloride and distilled, bp 85 C. [Pg.97]

Recryst from H2O or 50% aq EtOH. Alternatively, dissolve ca 3g in cone HCl (lOmL) and evaporate to dryness. Dissolve the residual hydrochloride in the minimum volume of warm H2O and make faintly alkaline with aq NH3. Collect the crystals and dry in a vacuum at 100 . [J Am Chem Soc 56 134 1934.]... [Pg.138]


See other pages where Volume cones is mentioned: [Pg.535]    [Pg.538]    [Pg.394]    [Pg.134]    [Pg.496]    [Pg.182]    [Pg.954]    [Pg.278]    [Pg.66]    [Pg.535]    [Pg.538]    [Pg.394]    [Pg.134]    [Pg.496]    [Pg.182]    [Pg.954]    [Pg.278]    [Pg.66]    [Pg.40]    [Pg.189]    [Pg.218]    [Pg.1804]    [Pg.1958]    [Pg.393]    [Pg.484]    [Pg.137]    [Pg.129]    [Pg.224]    [Pg.770]    [Pg.395]    [Pg.388]    [Pg.56]    [Pg.438]    [Pg.8]    [Pg.252]    [Pg.256]    [Pg.429]    [Pg.1790]    [Pg.1791]    [Pg.37]    [Pg.139]   
See also in sourсe #XX -- [ Pg.302 ]




SEARCH



© 2024 chempedia.info