Conductivity flow-through

The narrow bore of the capillary column and the relative thickness of the capillary s walls are important. When an electric field is applied to a capillary containing a conductive medium, such as a buffer solution, current flows through the capillary. This current leads to Joule heating, the extent of which is proportional to the capillary s radius and the magnitude of the electric field. Joule heating is a problem because it changes the buffer solution s viscosity, with the solution at the center of the... [Pg.601]

Measurement by Electromagnetic Effects. The magnetic flow meter is a device that measures the potential developed when an electrically conductive flow moves through an imposed magnetic field. The voltage developed is proportional to the volumetric flow rate of the fluid and the magnetic field strength. The process fluid sees only an empty pipe so that the device has a very low pressure drop. The device is useful for the measurement of slurries and other fluid systems where an accumulation of another phase could interfere with flow measurement by other devices. The meter must be installed in a section of pipe that is much less conductive than the fluid. This limits its appHcabiHty in many industrial situations. [Pg.110]

The carbon blacks used in plastics are usually different from the carbon blacks used in mbber. The effect of carbon black is detrimental to the physical properties of plastics such as impact strength and melt flow. Electroconductive grades of carbon black have much higher surface areas than conventional carbon blacks. The higher surface areas result in a three-dimensional conductive pathway through the polymer at much lower additive levels of the carbon black. The additive concentrations of electroconductive carbon blacks is usually j to that of a regular carbon black (132). [Pg.296]

By far the most used detector is the thermal conductivity detector (TCD). Detectors like the TCD are called bulk-property detectors, in that the response is to a property of the overall material flowing through the detector, in this case the thermal conductivity of the stream, which includes the carrier gas (mobile phase) and any material that may be traveling with it. The principle behind a TCD is that a hot body loses heat at a rate that depends on the... [Pg.107]

Thermal conductivity describes the ease with which conductive heat can flow through a vapor, hquid, or sohd layer of a substance. It is defined as the proportionahty constant in Fourier s law of heat conduction in units of energy length/time area temperature e.g., W/m K. [Pg.411]

Flashback tests incorporate a flame arrester on top of a tank, with a large plastic bag surrounding the flame arrester. A specific gas mixture (for example, propane, ethylene, or hydrogen at the most sensitive composition in air) flows through and fills the tank and the bag. Deflagration flames initiated in the bag (three at different bag locations) must not pass through the flame arrester into the tank. On the unpro-tec ted side, piping and attachments such as valves are included as intended for installation a series of tests—perhaps ten—is conducted. [Pg.2304]

A simple case of heat conduction is a plate of finite thickness but infinite in other directions. If the temperature is constant around the plate, the material is assumed to have a constant thermal conductivity. In this case the linear temperature distribution and the heat flow through the plate is easy to determine from Fourier s law (Eq. (4.154)). [Pg.112]

The mass flow total /j for each zone i is set up flows through the individual conductances connected with zone nj, number of conductances connected with zone i), and the requirement of mass flow balance for each zone i leads to the iterative solution for the unknown zone pressures p = (pj, pj,..., Pi)-... [Pg.1086]

Recognize that only the heat that flows through the sum of all the resistances can flow through any one resistance considered individually, even though by itself, a resistance may be capable of conducting or transferring more heat. [Pg.88]

In the parallel configuration, the same potential difference occurs across each and every element with the total current being the algebraic sum of the current flowing through each individual circuit element. Table 2-35 summarizes the equivalent resistance, conductance, capacitance, and inductance of series-parallel configurations of resistors, capacitors, and inductors. [Pg.284]

Make-up water. A semi-sealed section within the main tank will feed water from the treatment plant to the main tank either through a separate make-up tank or. In either case, the water level will be the same in both sections, excluding the ullage left for condense returns. Control of the make-up water level may be by float valve, float switches or conductivity probes. These methods allow water to flow through the treatment plant, although conductivity probes or switches permit a positive flow and avoid the risk of slippage. [Pg.359]

Conducted heat is that going in through cold store surfaces, tank sides, pipe insulation, etc. It is normally assumed to be constant and the outside temperature an average summer temperature, probably 25-2/°C for the UK, unless some other figure is known. Coldroom surfaces are measured on the outside dimensions and it is usual to calculate on the heat flow through the insulation only, ignoring other construction materials, since their thermal resistance is small. [Pg.216]

Ion chromatography (see Section 7.4). Conductivity cells can be coupled to ion chromatographic systems to provide a sensitive method for measuring ionic concentrations in the eluate. To achieve this end, special micro-conductivity cells have been developed of a flow-through pattern and placed in a thermostatted enclosure a typical cell may contain a volume of about 1.5 /iL and have a cell constant of approximately 15 cm-1. It is claimed15 that sensitivity is improved by use of a bipolar square-wave pulsed current which reduces polarisation and capacitance effects, and the changes in conductivity caused by the heating effect of the current (see Refs 16, 17). [Pg.522]

A novel development of the use of ion-selective electrodes is the incorporation of a very thin ion-selective membrane (C) into a modified metal oxide semiconductor field effect transistor (A) which is encased in a non-conducting shield (B) (Fig. 15.4). When the membrane is placed in contact with a test solution containing an appropriate ion, a potential is developed, and this potential affects the current flowing through the transistor between terminals Tt and T2. [Pg.563]

At the level of a single channel, addition of ACh is followed by transient openings of the channel. The current i flowing through an open channel is 4 pA at a membrane potential Voi-l 00 mV. Since one ampere (A) represents the flow of 6.24-1018 charges per second, 2.5-107 Na+ ions per second flow through an open channel. The conductance g of a plasma membrane channel is the measure of the ease of flow of cuirent between the extracellular space and the cytosol or vice... [Pg.871]

In many channels the relation between current and membrane potential is nonlinear. These channels show rectification, i.e., the property of the channel to conduct ions more readily in one direction than in the other. Depending on the preferential current flow through channels, these are described as outward or inward rectifying. [Pg.1063]


See other pages where Conductivity flow-through is mentioned: [Pg.26]    [Pg.300]    [Pg.496]    [Pg.113]    [Pg.411]    [Pg.412]    [Pg.428]    [Pg.219]    [Pg.247]    [Pg.412]    [Pg.498]    [Pg.29]    [Pg.73]    [Pg.139]    [Pg.474]    [Pg.764]    [Pg.1472]    [Pg.2409]    [Pg.360]    [Pg.101]    [Pg.102]    [Pg.111]    [Pg.155]    [Pg.892]    [Pg.430]    [Pg.605]    [Pg.614]    [Pg.615]    [Pg.647]    [Pg.999]    [Pg.27]    [Pg.685]    [Pg.249]    [Pg.70]    [Pg.656]   
See also in sourсe #XX -- [ Pg.505 ]




SEARCH



Estimation of heat flow through a composite wall with constant thermal conductivities

Flow conductance

Flow-through