Calibration spectral

Preparation of TNT Standard Solutions and TNT Spectral Calibration Graph. Prepare a stock TNT soln. Accurately weigh and transfer 8g of TNT into a-500-ml volumetric flask. Dilute to mark with ethylene chloride... [Pg.30]

Prepare the TNT spectral calibration graph by detg the absorbance at 367 mu of the standard TNT solns at 20°C compared to a soln of 0.400g of TNT/50ml of ethylene chloride using 1 mm path cells. Plot absorbance against weight of TNT... [Pg.30]

Spectral calibration curves for a t)247 quartz prism monochromator with either an EMI 6256 or 9558 photomultiplier are shown in Figure 5. Most of the spectra to be presented later have not been corrected but... [Pg.317]

For the determination of the spectral sensitivity complicated and expensive laboratory equipment are required in conjunction with experienced personnel. Such a facility should be capable in providing calibrated monochromatic radiation of sufficient power to be sensed by the broadband detector in question. A typical system should be comprised by a double monochromator coupled with a stable, high-power source (e.g. a 1000-Watt Xenon lamp). A spectrally calibrated detector should also be available to measure the quasi-monochromatic radiation emitted by this system. Such facilities are rarely available and only a few laboratories worldwide are able to cany out such characterizations. [Pg.200]

Predict the concentrations of A in the calibration set using MLR and assuming only compound A can be calibrated, as follows, (i) Determine the vector s = c. X/Y c2, where X is the 25 x 22 spectral calibration matrix and c a 25 x 1 vector, (ii) Determine the predicted concentration vector c = X.s / s2 (note that the denominator is simply the sum of squares when only one compound is used). [Pg.330]

Siddiqui et al. [28] developed and validated an analytical spectral calibration method to quantify buclizine hydrochloride, which is a piperazine derivative and used a single active principle in pharmaceutical forms were done. The quantification of buclizine hydrochloride was performed in the wavelength range of 218-226 nm at N = 6. The linear regression equation has been constructed using relationship between concentration and absorbance at 218, 220, 222, 224, and 226 nm. [Pg.30]

There are commercial sources of reference materials for spectral calibration that are traceable to the NIST standards. See, for example Stama Cells, Inc. ( www.stamacells.coml. [Pg.495]

Although laser sources are rapidly dominating spectral calibration in the visible and infrared regions, plasma sources are still attractive for the vacuum u.v. A... [Pg.3]

Whilst these standards are mostly prepared simply within the solvent matrix used, variations on this theme may result in inclusion of these standards actually within the sample matrix. These procedures are often referred to as internal standardization, standard addition, or standard recovery, depending on the actual implementation of how the known analyte addition is used within the spectrophoto-metric method. These procedures either provide spectral calibration or method quality assurance data. For example, spectroscopic methods will often require pretreatment to remove the interfering sample matrix. Addition of a known amount of the test analyte spike (at the expected level) to a sample is... [Pg.3995]

The mercury spectrum is even less regular. The electron configuration in Hg consists of two valence electrons outside of a closed-shell core. .. (5s) (5p) (4/) (5d) . The Hg spectrum features that are not anticipated in H or K arise from electron spin multiplicity (i.e., the formation of triplet as well as singlet excited states in atoms with even numbers of valence electrons) and from spin-orbit coupling, which assumes importance in heavy atoms like Hg (Z = 80). The mercury spectrum in Fig. 2.2 has been widely used as a spectral calibration standard. [Pg.36]

Numerous techniques have been developed to improve the robusmess and transportability of spectral calibration models [58-68]. Among them, the computation of first and second derivatives of spectral data with respect to the wavelength and the application of multiplicative scatter corrections (MSCs) certainly are the most popular ones. Derivatives of spectral data allow for efficient removal of baseline shifts and for magnification of small changes of the spectral signal. However, derivation of spectral data could increase the effects of noisy measurements. MSC was developed to... [Pg.115]

Although NN models are capable of describing very complex nonlinear behaviors, as shown extensively in the literature, the use of NN models for spectral calibrations has not led to any significant improvement of model responses [55-57]. Nevertheless, numerous successful attempts have been made to use NNs for the interpretation of spectral data [78-80]. [Pg.118]

NIR diffuse reflection single-element detector spectroscopy (spectral resolution 16 cm spectral calibration range 9050 - 7450 cm 7100 - 5570 cm... [Pg.385]

NIR diffuse reflection imaging spectroscopy (spectral resolution 24cm spectral calibration range 10417-6017cm... [Pg.385]


See other pages where Calibration spectral is mentioned: [Pg.29]    [Pg.31]    [Pg.32]    [Pg.32]    [Pg.332]    [Pg.3826]    [Pg.29]    [Pg.31]    [Pg.32]    [Pg.32]    [Pg.127]    [Pg.291]    [Pg.341]    [Pg.341]    [Pg.260]    [Pg.662]    [Pg.521]    [Pg.3825]    [Pg.150]    [Pg.1409]    [Pg.99]    [Pg.250]    [Pg.353]    [Pg.365]    [Pg.466]    [Pg.567]    [Pg.676]    [Pg.118]    [Pg.142]    [Pg.116]    [Pg.385]    [Pg.291]   