Equivalent columns

Distill a small quantity each day to obtain relatively pure o-xylene from a mixture of ortho and para xylene, having boiling points of 142.7°C and 138.4°C, respectively. The feed is 15 Ib-mols (about 225 gallons) per batch, at 0.20 mol fraction para. The desired residue product is 0.020 in the kettle, while the distillate is to be 0.400 mol fraction para. A distillation column equivalent to 50 theoretical plate is to be used. [Pg.53]

The water pressure exerted at the base of a water column, equivalent to 0.433 psia per vertical foot. [Pg.741]

Inject the fraction of interest (biologically active, immune induced) on two serially linked size exclusion columns (equivalent to the former Beckman SEC 3000 and SEC 2000 columns, 300 mm x 7.5 mm or any other brand). Use of a precolumn is recommended to protect expensive columns. The injected volume should not exceed 100 p.L for adequate resolution. [Pg.21]

FIG. 13-69 Dividing wall columns equivalent to a) side rectifier configuration, h) side stripper configuration, (c) thermally coupled system. [Pg.63]

All the multicomponent thermally coupled configurations have a corresponding divicfing wall column equivalent. Keibel [Chem. Eng. Teehnol., 10, 92 (1987)] has shown examples of columns with multiple dividing walls, separating three, four, and six components. Agrawal [Ind. Eng. Chem. Res., 40, 4258 (2001)] presented several examples of quaternary columns with partitions and multiple reboilers and condensers. One of these examples is shown in Fig. 13-73. [Pg.64]

Other oxides of nitrogen are present in these systems, and they affect the single stage enrichment factor a = ( N/ N)iiquid/( N/ N)gas as well as the interphase transfer rate as measured by the height of the column equivalent to a theoretical plate (HETP). [Pg.120]

Figure 1, Panel A shows the RP-HPLC chromatogram of the combined digest (Endo Lys-C followed by chymotrypsin) of MIANS-ricin A-chain detected at 214 and 320 nm. There are only 6 major peptides that are MIANS-labeled as evidenced by the 320 nm profile. All of these peptides bind to and are eluted from the anti-MlANS column as shown in Panel B of Figure 1. Moreover, as the profile at 214 nm shows, there is no evidence of significant amounts of additional, unlabeled peptides sticking to the affinity column. Note also that the ratio of the peaks in the 320 nm chromatogram of Panel B is the seune as that in the 320 nm chromatogram of Panel A, indicating that each of the MIANS-labeled peptides binds to the affinity column equivalently. Figure 1, Panel A shows the RP-HPLC chromatogram of the combined digest (Endo Lys-C followed by chymotrypsin) of MIANS-ricin A-chain detected at 214 and 320 nm. There are only 6 major peptides that are MIANS-labeled as evidenced by the 320 nm profile. All of these peptides bind to and are eluted from the anti-MlANS column as shown in Panel B of Figure 1. Moreover, as the profile at 214 nm shows, there is no evidence of significant amounts of additional, unlabeled peptides sticking to the affinity column. Note also that the ratio of the peaks in the 320 nm chromatogram of Panel B is the seune as that in the 320 nm chromatogram of Panel A, indicating that each of the MIANS-labeled peptides binds to the affinity column equivalently.
Carrying out distillation using a vacuum (low pressure) allows use of lower temperatures and attains higher alcohol concentrations. For instance, at 42 mm Hg pressure (about 6 percent of atmospheric pressure (Normal atmospheric pressure is 760 mm Hg (millimeters of mercury column), equivalent to 30 inches of Hg or 14.7 psi. Thus, 6 percent of 14.7 psi is approximately 0.88 psi.), the temperature at the bottom of the column need only be about 35° C (95° F) and the top about 20° C (68° F). This makes it hard to condense the vapor, since there is a smaller temperature difference between the vapor and the coolant (whether air or water). But this pressure may be advantageous if heat is supplied at only 35° C Here, waste heat from other machinery or solar heat might be exploited. [Pg.15]

A binary distillation operation separates 78.1 mol/s of a mixture of 46 mol% benzene and 54 mol% toluene. The purpose of the sieve-tray column (equivalent to 20 theoretical stages and a partial reboiler) is to separate the feed into a liquid distillate of 99 mol% benzene and a liquid bottoms product of 98 mol% toluene. The pres-... [Pg.357]

Recent developments in coating technology have enabled cross-linked styrene divinylbenzene porous copolymers to be successfully immobilised on the silica wall of a capillary column. These PLOT columns have similar retention properties to the packed column equivalents but with higher resolution. PoraPLOT columns with Porapak Q, S or U stationary phases are general purpose columns suitable for the analysis of C) -C4 hydrocarbons, chlorofluorocarbons and atmospheric pollutants [35,36]. [Pg.200]

Fig. 16.6. Net phosphate transformation rates in September 1989 in the water column (solid line) and in the sediment (converted to water-column equivalent rates dashed line). Reproduced from Omiin etal. (2001a) with permission from Elsevier Science. Fig. 16.6. Net phosphate transformation rates in September 1989 in the water column (solid line) and in the sediment (converted to water-column equivalent rates dashed line). Reproduced from Omiin etal. (2001a) with permission from Elsevier Science.
The top tray is now labeled as Stage 1 in this absorber model. So the feed stage and the bottom stage must be decreased by one to make this column equivalent to the basic column. The feed and reflux are fed to column along with a partially vaporized stream from the... [Pg.389]

Length of column equivalent to fully mixed wake L Slug length... [Pg.64]

The issue of column equivalency is of major importance to regulatory bodies such as the Food Drug Administration (FDA), the United States Pharmacopoeia (USP), and the European Pharmacopoeia (EP) commissions. [Pg.271]

The selectivity of a chromatographic method is determined by the column stationary phase chemistry and the mobile phase composition consequently, it is advisable to keep the mobile phase and column chemistry the same when the method is transferred between HPLC and UHPLC. This means that in labs where exchange of methods between instrument types is anticipated, chromatographers are advised to choose column brands where both UHPLC and HPLC columns with the same stationary phase chemistry are available. Table 3.7 lists the column brands currently provided by the major manufactures. It can be seen that not all brands carry both columns packed with the conventional 3-5 xm and the sub-2 xm particle sizes. Within each brand, not all stationary phases are available in both platforms. In such situations, column equivalence assessment needs to be performed to find the best alternative column by using tools such as the reversed-phase colunm selectivity charts available from column vendors. [Pg.83]


See other pages where Equivalent columns is mentioned: [Pg.646]    [Pg.84]    [Pg.134]    [Pg.470]    [Pg.818]    [Pg.146]    [Pg.277]    [Pg.326]    [Pg.373]    [Pg.246]    [Pg.552]    [Pg.293]   
See also in sourсe #XX -- [ Pg.7 ]