Column body, material

The column body material is glass or metal (e.g., stainless steel). [Pg.25]

In subsequent work, it was shown that a renewable separation-column approach could be used to capture and purify "Tc on a TEVA-Resin column set up between a pair of 2-position valves, as shown in Figure 9.6.83 After loading the sample and washing away interferences, the separation material was released from the column and delivered downstream to a collection vial. Scintillation cocktail was added to the vial off-line and the "Tc was determined radiometrically. In this approach, there is no need to elute the "Tc with strong acid, and a fresh suspension of separation material is delivered to the column body for each sample. [Pg.531]

In this formula, the distance r between the mass centers has been replaced by the sum of the radius of the reference body (earth) and of the altitude z. The altitude origin (z = 0) corresponds to the surface of this body. Equation K3.14 is therefore a general model of a column of material in a Newtonian (linear medium) gravity field. In order to retrieve the barometric Equation K3.1, a certain number of approximations must be made. The first one is to assume a constant gravity field, thus allowing the writing of the gravitational capacitive relationship in Equation K3.14 as... [Pg.698]

Clean or change injection port liners frequently because nonvolatile materials in extracts from body fluids can accumulate in the injection port and/or head of the GC column and cause separation problems. [Pg.58]

The thermal conductivity detector (TCD) is a universal detector that is nondestructive, which is a major advantage for preparative work (Dybowski and Kaiser, 2002). However, it is not sensitive enough for many of the analyses discussed later. This detector operates on the principle that a hot body loses heat at a rate dependent on the composition of the material surrounding it (Burtis et ah, 1987). In a TCD, two filaments are heated, one in carrier gas, and the other in the column effluent. The voltages required to maintain the filament at a constant temperature are measured and compared. When compounds elute from the column the voltage of the sample filament is different from that of the filament in carrier gas and is recorded as a peak (Burtis et al., 1987). [Pg.4]

Figure 19.24 A real folding funnel. Refolding chromatography of IGPS (49-252) (indole 3-glycerol phosphate synthase lacking residues 1 -48). Denatured IGPS from an inclusion body was dissolved in 8-M urea and diluted onto a 3-mL column of a GroEL minichaperone (GroEF) that was immobilized on agarose. Ninety-six percent of the protein eluted as fully active material. Figure 19.24 A real folding funnel. Refolding chromatography of IGPS (49-252) (indole 3-glycerol phosphate synthase lacking residues 1 -48). Denatured IGPS from an inclusion body was dissolved in 8-M urea and diluted onto a 3-mL column of a GroEL minichaperone (GroEF) that was immobilized on agarose. Ninety-six percent of the protein eluted as fully active material.
Body fluids, such as serum, contain several different carotenoids in low amounts. The crucial point in the isolation and analysis of these samples is the enrichment factor. Serum samples can be directly analysed with hyphenated extraction-sample enrichment-separation systems, such as on-line SPE-HPLC employing tailored stationary phases [29]. By using special restricted access materials (RAMs) for sample enrichment, the carotenoids are retarded on the pre-column while the protein binding is broken and the macromolecules are eluted. The preparation of artifacts is hindered, as the whole analysis steps take place under conditions of light- and oxygen-exclusion. The scheme of on-line SPE-HPLC is presented in Figure 5.2.2. [Pg.130]

Micro-injections in micro-flow and nano-flow systems are done with injectors in which the external sample loop is replaced with the internal fixed volume within the injector body. HPLC-on-a-chip systems also build the column into the injector body. The internal path within the injector body is abladed with a laser, packed with micro-packing material, and this serves as the separating media. The injector inlet is connected to the pumping system and the outlet to the detector. Sample is loaded into an internal loop in the load position, then injected onto the chip HPLC by turning the injector. Obviously, in a system like this sample size is very limited and the detector is usually a highly sensitive mass spectrometer. [Pg.116]

Chip HPLC—Nano-flow, micro-sample HPLC system in which the packed column resides within the body of the injector. Originally touted as the HPLC of the future for nano-level LC/MS, but its potential has been slow to materialize. [Pg.214]

HPLC is the technique of choice for determining the purity of moxalactam disodium in raw materials, formulated products, and in body fluids. Moxalactam is determined in a system containing 0.05 to 0.1 M ammonium acetate with about 6 percent methanol present. An ES Industries Chromegabond C18 column or other alternative column with similar retention characteristics is used to determine the purity of the moxalactam sample. The substance may be monitored at 254 nm or, when available, a variable wavelength detector can be operated at 271 nm for assay. The sample is dissolved in water or in 0.1 M ammonium acetate solution. Under conditions of this method, the assay should be completed within 4 hours of sample dissolution. [Pg.324]


See other pages where Column body, material is mentioned: [Pg.537]    [Pg.68]    [Pg.171]    [Pg.864]    [Pg.150]    [Pg.92]    [Pg.266]    [Pg.54]    [Pg.52]    [Pg.165]    [Pg.21]    [Pg.287]    [Pg.691]    [Pg.910]    [Pg.158]    [Pg.365]    [Pg.200]    [Pg.7]    [Pg.717]    [Pg.320]    [Pg.1011]    [Pg.1033]    [Pg.250]    [Pg.467]    [Pg.282]    [Pg.52]    [Pg.1407]    [Pg.276]    [Pg.291]    [Pg.439]    [Pg.433]    [Pg.105]    [Pg.340]    [Pg.77]    [Pg.310]    [Pg.90]    [Pg.150]    [Pg.68]    [Pg.3087]    [Pg.294]    [Pg.307]   