Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Column, adsorption liquid-partition

Tswett s initial column liquid chromatography method was developed, tested, and applied in two parallel modes, liquid-solid adsorption and liquid-liquid partition. Adsorption ehromatography, based on a purely physical principle of adsorption, eonsiderably outperformed its partition counterpart with mechanically coated stationary phases to become the most important liquid chromatographic method. This remains true today in thin-layer chromatography (TLC), for which silica gel is by far the major stationary phase. In column chromatography, however, reversed-phase liquid ehromatography using chemically bonded stationary phases is the most popular method. [Pg.3]

Liquid/liquid partition chromatography was explored by Willstatter from 1913. The process was extensively developed by Martin and Synge (ca. 1941-1948) who partitioned amino acid derivatives between chloroform and water using precipitated silica as support for the aqueous phase. The preparations of silica were again very variable and it was difficult to prevent adsorption which interfered with the expected behavior of the aminoacids. At first methyl orange was added to the water phase to visualize the amino acids the separation of the acids then caused a red band to move down the columns. The quantitative reaction with ninhydrin was introduced by Moore and Stein in 1948 for both the detection and estimation of the amino acids. Consid-... [Pg.174]

While gravity-fed columns including adsorption or ion exchange are recommended when extensive sample cleanup is required, the analyst should be cautious about contamination and adsorptive effects contributing to sample loss. Liquid-liquid partitioning is the preferred technique. When concentrating solvents, care should be taken to insure against loss of volatile extracts. Plastic equipment or fibrous filters should be avoided. [Pg.610]

LIQUID CHROMATOGRAPHY. An analytical method based on separation of the components of a mixture in solution by selective adsorption. All systems include a moving solvent, a means of producing solvent motion (such us gravity or a pump I, a means ol sample introduction, a fractionating column, and a detector. Innovations in functional systems provide the analytical capability for operating in three separation modes (1) liquid-liquid partition in which separations depend on relative solubilities of sample components in two immiscible solvents (one of which is usually water) 12) liquid-solid adsorption where the differences in polarities nf sample components and their relative adsorption on an active surface determine tile degree ol separation (2) molecular size separations which depend on the effective molecular size of sample components ill solution. [Pg.932]

Chromatographic and electrophoretic separations are truly orthogonal, which makes them excellent techniques to couple in a multidimensional system. Capillary electrophoresis separates analytes based on differences in the electrophoretic mobilities of analytes, while chromatographic separations discriminate based on differences in partition function, adsorption, or other properties unrelated to charge (with some clear exceptions). Typically in multidimensional techniques, the more orthogonal two methods are, then the more difficult it is to interface them. Microscale liquid chromatography (p.LC) has been comparatively easy to couple to capillary electrophoresis due to the fact that both techniques involve narrow-bore columns and liquid-phase eluents. [Pg.200]

The Food and Drug Administration [FDA] Pesticide Analytical Methods Manual QJ and the Environmental Protection Agency [EPA] Manual for Environmental Analysis (2) describe procedures that have been used for many years. Two of the commonly applied techniques are liquid-liquid partitioning and column adsorption chromatography. These approaches are used to isolate lipohilic and moderately polar residues for primary identification and quantitation with GLC. An evaluation of the number of pesticide residues that were satisfactorily analyzed by this approach was published by McMahon and Burke (3). When one looks at the data it can be seen that the highly polar and water soluble residues do not fit into the analytical scheme very well. In an attempt to rectify this problem, FDA is modifying the multiresidue method... [Pg.209]

Sorption of Cu(tfac)2 on a column depends on the amount of the compound injected, the content of the liquid phase in the bed, the nature of the support and temperature. Substantial sorption of Cu(tfac)2 by glass tubing and glass-wool plugs was observed. It was also shown that sorption of the copper chelate by the bed is partialy reversible . The retention data for Cr(dik)3, Co(dik)3 and Al(dik)3 complexes were measured at various temperatures and various flow rates. The results enable one to select conditions for the GC separation of Cr, Al and Co S-diketonates. Retention of tfac and hfac of various metals on various supports were also studied and were widely used for the determination of the metals. Both adsorption and partition coefficients were found to be functions of the average thickness of the film of the stationary phase . Specific retention volumes, adsorption isotherms, molar heats and entropy of solution were determined from the GC data . The retention of metal chelates on various stationary phases is mainly due to adsorption at the gas-liquid interface. However, the classical equation which describes the retention when mixed mechanisms occur is inappropriate to represent the behavior of such systems. This failure occurs because both adsorption and partition coefficients are functions of the average thickness of the film of the stationary phase. It was pointed out that the main problem is lack of stability under GC conditions. Dissociation of the chelates results in a smaller peak and a build-up of reactive metal ions. An improvement of the method could be achieved by addition of tfaH to the carrier gas of the GC equipped with aTCD" orFID" . ... [Pg.701]

In gas chromatography (GC), a gaseous solute (or the vapour from a volatile liquid) is carried by the gaseous mobile phase. In gas-liquid partition chromatography, the stationary phase is a non-volatile liquid coated on the inside of the column or on a fine support. In gas-solid adsorption chromatography, solid particles that adsorb the solute act as the stationary phase. [Pg.211]

The main equations required to solve several column chromatography problems are presented below and in the example calculations. These equations are based upon a liquid-liquid partition process rather than an adsorption process and are usually valid only for processes involving very dilute systems. [Pg.156]

There are two types of GC gas-solid (adsorption) chromatography and gas-liquid (partition) chromatography. The more important of the two is gas-liquid chromatography (GLC), used in the form of a capillary column. In this chapter, we describe the principles of operation of gas chromatography, the types of GC columns, and GC detectors. The principles of mass spectrometry (MS) are described, along with coupling of the gas chromatograph with a mass spectrometer (GC-MS). [Pg.574]


See other pages where Column, adsorption liquid-partition is mentioned: [Pg.642]    [Pg.367]    [Pg.97]    [Pg.578]    [Pg.822]    [Pg.91]    [Pg.527]    [Pg.610]    [Pg.611]    [Pg.624]    [Pg.232]    [Pg.80]    [Pg.315]    [Pg.459]    [Pg.174]    [Pg.363]    [Pg.104]    [Pg.557]    [Pg.391]    [Pg.503]    [Pg.12]    [Pg.80]    [Pg.636]    [Pg.231]    [Pg.84]    [Pg.76]    [Pg.92]    [Pg.32]    [Pg.491]    [Pg.539]    [Pg.555]    [Pg.961]    [Pg.1149]    [Pg.1457]    [Pg.29]    [Pg.9]    [Pg.761]    [Pg.78]    [Pg.41]   
See also in sourсe #XX -- [ Pg.277 , Pg.278 ]




SEARCH



Adsorption columns

Liquid adsorption

Liquid column

© 2024 chempedia.info