Closed cycle refrigerators

In the technique of matrix isolation (hereafter denoted "MI"), samples which are liquid or solid at room temperature are vaporized under vacuum, and then mixed with a large excess of a diluent gas (termed the "matrix gas") which in effect, is the "solvent" in the spectroscopic analysis. This gaseous mixture is then deposited on a cold surface for spectroscopic analysis as a solid For most purposes, temperatures of 15 K (which can be obtained by use of commercial closed-cycle refrigerators) are satisfactory for some specialized fluorescence experiments,... [Pg.248]

Fig. 3.16 The FDS at LANSCE (a) schematic and (b) cut-away view. Key filter, detectors, shielding, closed cycle refrigerator to cool filter, shielding, sample (usually annular or cylindrical), cryostat for sample, incident beam tube. Reproduced from [20] with permission from Elsevier. Fig. 3.16 The FDS at LANSCE (a) schematic and (b) cut-away view. Key filter, detectors, shielding, closed cycle refrigerator to cool filter, shielding, sample (usually annular or cylindrical), cryostat for sample, incident beam tube. Reproduced from [20] with permission from Elsevier.
Fig. 7. Miniature Raman cell for frozen protein solutions that, once loaded with sample, can conveniently be shipped between laboratories in dry ice or liquid Nj and then attached without further manipulation to a helium closed-cycle refrigerator (CCR) station for RR measurements. The main advantages of this design are as follows (1) very small quantities of sample are required (1-2 drops) (2) the cell atmosphere can be controlled (3) cryogenic temperatures are obtained, down to 10 K and (4) Raman scattering originates directly from the surface of a frozen solution without interferences from glass or quartz scattering. ... Fig. 7. Miniature Raman cell for frozen protein solutions that, once loaded with sample, can conveniently be shipped between laboratories in dry ice or liquid Nj and then attached without further manipulation to a helium closed-cycle refrigerator (CCR) station for RR measurements. The main advantages of this design are as follows (1) very small quantities of sample are required (1-2 drops) (2) the cell atmosphere can be controlled (3) cryogenic temperatures are obtained, down to 10 K and (4) Raman scattering originates directly from the surface of a frozen solution without interferences from glass or quartz scattering. ...
The gas handling system used for sample preparation was described previously . An Air Products low temperature closed cycle refrigerator was used to maintain the sample temperature. The refrigerator was mounted in a rotable flange at a position above the point marked RS in Fig. 1 such that a 180° rotation allowed a matrix to be deposited, irradiated or its infrared spectrum recorded. [Pg.499]

Warm-up tests of the cryopump cold plate demonstrated a low refrigerative requirement. As a result it becomes possible to supply the refrigeration with dense helium gas from sources other than closed-cycle refrigerators. A simple source of the gas is accelerated boil-off gas from a liquid-helium storage dewar. [Pg.489]

Expansion piston engines are widely used in producing liquid helium and in closed-cycle refrigerators for various other applications in the region of low temperatures. Most of these technical and research applications require reliable continuous operation for periods of weeks or months. For this reason an expansion engine with a minimum of moving parts and with complete gas lubrication of the piston within the cylinder has the best chance to overcome the difficulties inherent in present-day low-temperature refrigerators. [Pg.561]

The intrinsic linewidth of the diode laser should be in the 10 KHz range. This differs drastically from experimental observations, where a jitter of 20-200 MHz can occur. The reason for this seems to be optical feedback into the laser cavity by any of the windows between the crystal and the spectroscopic system. Thus in most of the available systems, the periodic vibrations caused by the closed cycle refrigerator, can be seen directly in the jitter of the laser [1,12], (Fig.1.11). [Pg.19]

Akt] A computerized ac susceptometer with a closed cycle refrigerator between 25 and -263°C Magnetic susccptibihty... [Pg.43]

The use of He for cooling to temperatures below 1 K requires a closed system dictated by the cost ( 0.15/cc at STP) and availability of gas. A closed cycle refrigerator has been designed and performance data are predicted from the T-S diagram which has been computed below 2"Kfrom recent experimental data. A comparison between predicted and observed performance is given. [Pg.345]

Kryostat Displex Closed Cycle Refrigeration System CSA 202 der Fa. Air... [Pg.127]

Mossbauer spectrometer equipped with a helium closed-cycle refrigerator used in this work. [Pg.205]

Fig. 6 Schematic of the ion trap tandem mass spectrometer employed by Asmis and co workers [109]. The cold trap (H) is cooled by a closed cycle refrigerator and uses helium for buffer-gas cooling of the trapped ions, FELIX is the name of the infrared free electron laser... Fig. 6 Schematic of the ion trap tandem mass spectrometer employed by Asmis and co workers [109]. The cold trap (H) is cooled by a closed cycle refrigerator and uses helium for buffer-gas cooling of the trapped ions, FELIX is the name of the infrared free electron laser...
The experimental apparatus for matrix isolation experiments is designed with the methods of generating the molecular transient and performing the spectroscopy in mind. Figure 1 is a schematic diagram of the laser-ablation matrix isolation apparatus for infrared absorption spectroscopy. Caesium iodide windows are typically employed. The rotatable cold window is cooled to 4-20 K by closed-cycle refrigeration or liquid helium. The matrix sample is introduced... [Pg.96]

The upper frequency limit of Nb SIS devices, about 700 GHz, is set by the increase in the loss above the Nb gap frequency. Further progress in the frequency of SIS devices has been related to NbN junctions with a highest gap frequency of about 1200 GHz. An experimental study was performed in the millimeter band with a full NbN SIS mixer (71-76). The lowest double sideband (DSB) receiver noise temperature is about 65 K at 160 GHz and approaches the Nb SIS mixer performance in the millimeter band. The NbN SIS junctions can be operated at temperature of 5.4 K, which is unacceptable with the Nb devices. This means that the introduction of low-noise NbN mixers may simplify closed-cycle refrigerators. [Pg.297]

Cryopanels (Meissner traps) are cryocondensation surfaces in the deposition chamber that use large areas of cooled surfaces to freeze out vapors, particularly water vapor and solvent vapors. They are cooled by LN2 at — 196°C or refrigerants to about — 150°C from a closed-cycle refrigerator/compressor system. The vapor pressure of water at these temperatures is very low, as shown in Table 3.4. It takes about 780 watts to freeze one kilogram of water per hour and 11 kilograms of LN2 to freeze one kilogram of water. The ideal cryosurface should pump about 10 liters per second per square centimeter. [Pg.117]

Helium (4.2 K) is the coldest known cryogen, yet not prohibitively expensive, and it can be used in closed-cycle refrigerators. Helium has the lowest cooling capacity of the common cryogens it boils off very quickly, so it... [Pg.410]


See other pages where Closed cycle refrigerators is mentioned: [Pg.78]    [Pg.89]    [Pg.308]    [Pg.1578]    [Pg.181]    [Pg.169]    [Pg.54]    [Pg.220]    [Pg.328]    [Pg.126]    [Pg.301]    [Pg.104]    [Pg.120]    [Pg.1052]    [Pg.355]    [Pg.212]    [Pg.127]    [Pg.127]    [Pg.289]    [Pg.73]    [Pg.10]    [Pg.30]    [Pg.327]    [Pg.120]    [Pg.141]    [Pg.39]   